FCC Part 15.249 Certification
Test Report
FCC ID: SJS-380115WM
FCC Rule Part: 15.249
ACS Report Number: 07-0089-15C
Manufacturer: Mars Company
Model: 380115WM
Installation Guide
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598

MARS SmartTransmitter Installation Guide
To ensure proper connection and resistance to water intrusion a
waterproof butt splice is required to connect the SmartRadio transmitter to
the meter register. The recommended type of connector is a Scotchlok™
connector. This type of connector is ideal because it provides a good
mechanical connection of the wires and a waterproofing gel that inhibits
water ingress.
This device is designed to be installed at or above ground level either
indoors or outdoors. Professional installation by factory trained personnel
is required for proper use and reliable communication.
Meter Connection Table
Manufacturer Radio
Red
Sensus Encoder R Encoder G Encoder B
Radio
Green
Radio
Black
Hersey Encoder R Encoder G Encoder B
Neptune Encoder B Encoder R Encoder G
Amco/ABB Scancoder Encoder G Encoder R Encoder B
Amco InVision Encoder B Encoder R Encoder Shld
Severn Trent Terminal 1 Terminal 3 Terminal 5
Severn Trent - Generation 2 Encoder R Encoder G Encoder B
Installation Steps
1. Refer to the table above for wiring color codes.
2. While holding the Scotchlok™ connector with the button facing down,
insert un-stripped wires fully into connector.
3. Once seated, use a crimper and firmly squeeze the connector until
you hear a snap and gel seeps out of the end of the connector.
4. Repeat steps 1-3 for the other two pairs of wires and test to ensure
the SmartRF is transmitting properly.