FCC Part 15 Subpart C
Transmitter Certification
Test Report
FCC ID: SJS-380101WM
FCC Rule Part: 15.249
ACS Report Number: 05-0301-15C
Manufacturer: MARS Company
Model: 380101WM
Installation Guide
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
MARS SmartRadio Installation Guide
To ensure proper connection and resistance to water intrusion a
waterproof butt splice is required to connect the SmartTransmitter to the
meter register. The recommended type of connector is a Scotchlok™
connector. This type of connector is ideal because it provides a good
mechanical connection of the wires and a waterproofing gel that inhibits
water ingress.
This device is designed to be installed at or above ground level outside of
buildings and meter pits. Professional installation by factory trained
personnel is required for proper use and reliable communication.
Meter Connection Table
Manufacturer
Sensus Encoder R Encoder G Encoder B
Radio
Red
Radio
Green
Radio
Black
Hersey Encoder R Encoder G Encoder B
Neptune Encoder B Encoder R Encoder G
Amco/ABB Scancoder Encoder G Encoder R Encoder B
Amco InVision Encoder B Encoder R Encoder Shld
Severn Trent Terminal 1 Terminal 3 Terminal 5
Severn Trent - Generation 2 Encoder R Encoder G Encoder B
Installation Steps
1. Refer to the table above for wiring color codes.
2. While holding the Scotchlok™ connector with the button facing
down, insert un-stripped wires fully into connector.
3. Once seated, use a crimper and firmly squeeze the connector until
you hear a snap and gel seeps out of the end of the connector.
4. Repeat steps 1-3 for the other two pairs of wires and test to ensure
the SmartTransmitter is transmitting properly.