Heat Pump Thermostats
HeatPumpDefrostThermostats
MARS heat pump defrost thermostats are designed for direct
eplacement of most existing controls of this type. The
r
33490
Electrical Ratings:
CYCLES RESISTIVE
X1000 VOLTS FLA LRA AMPS VA
100 120VAC 5.8 34.8 10 125
100 240VAC 2.9 17.4 10 125
30 120VAC 10.0 40.0 ––
30 240VAC 10.0 40.0 ––
100 30VDC –– 1 –
MARS
NO.
33490
33492
33494
33496
OPERATING TEMPERATURES F˚
OPEN CLOSE
80 30
80 30
65 30
65 30
temperature settings and tubing sizes have been carefully
selected from the most popular OEM settings. Each MARS
thermostat comes complete with extra long 54 inch leads,
mounting clamp, and installation instructions for fast and
simple field installation.
Features:
• Four controls cover most requirements
• Tapered mounting edge for maximum heat transfer
• Extra long 54 inch leads for simple wiring
• Individually boxed with mounting clamp and instructions
• UL & CUL listed
TUBE MOUNTING IN LEADS IN
ARS SERIES
M
3
/8 54
1
/2 54
3
/8 54
1
/2 54
COMPONENT
330
MARS Solid State Devices MARS SERIES 347
34790
Features:
• Adjustable 90 or 45 minute defrost interval
• Replaces GE directly
• Replaces Paragon with bracket
• Telechron S1 motor
• 50/60 Hertz
• UL and CSA listings available
MARS NO.
34790
DEFROST INTERVAL DEFROST TIMING PERIOD DEFROST INITIATION SWITCHING
90 or 45 10 50 Sec. SPST N.O.
MARS Heat Pump Defrost Timer
MARS Heat Pump Defrost Timer replaces General Electric and Paragon timers on heat
pumps with time initiated and time or temperature terminated defrost systems.
The MARS Heat Pump Timer features a defrost interval adjustment that allows selection
of either 90 minutes or 45 minutes between defrost periods.
The MARS Heat Pump Defrost Timer will replace Paragon timers used by Carrier,
Bryant, and other OEMs with the addition of a mounting bracket.
Specifications:
Time Delays: Digital Interval delay duration: jumper selectable as 45 or 90 min.
D faults to 45 min. if jumper wire is not connected.
Defrost Delay Duration: 10 min. or terminated upon the defrost thermostat opening
Defrost Window Delay Duration: 50 seconds
Operating Voltage: 240 VAC +10% - 25%
Output: relay/contactor output Type - solid state Form - SPDT N.O.
Rating - .50 amp steady state
Protection: 25% or greater shutdown
Surface Mount: With two #6 screws .25 inch male quick connect terminal
OperatingTemp: -40˚C to +85˚C
Humidity: 95% relative
The largest selection of motors, components, and accessories for the HVAC/R Industry