MARS Solid State Timers
ARS SERIES
M
MARS Fan Delay/Post Purge Timers
These MARS solid state timers provide for convenient control of a variety of functions.
MARS number 32393 is a fixed 2 minute, 24V off-delay timer that allows the fan to continue to operate after the thermostat is satisfied to purge the ducts of conditioned air.
MARS numbers 32377, 32378 and 32379 are versatile, high amp timers which, depending on installation (see connection diagrams 2 and 3), will perform either on-delay or off-delay functions. On-delay is especially useful for controlling unloader valves. Off-delay can be used for fan off-delay, pump down systems or post purge applications. The off-delay may also serve an anti-bounce function as a pump flutter bypass switch.
COMPONENT
WITHTHE SWITCH CLOSED,THE LOAD IS ENERGIZED.WHEN THE
SWITCH OPENS,THE LOAD RE-
MAINS ENERGIZED AND THETIME
DELAY BEGINS.ATTHE END OF
THE DELAY PERIODTHE LOAD IS
DE-ENERGIZED.
WHENTHE SWITCH CLOSES,THE TIME DELAY BEGINS.AT THE END
OFTHE DELAY PERIOD,THE LOAD
IS DE-ENERGIZED.
Features:
• Wide selection of models
• Easy installation
• Compact size
• Mounts in any position
• Totally solid state
• High accuracy
Specifications:
• 100 milliamps minimum latch current
TIME TYPE
MARS TYPE DELAY OF INPUT MAX VOLTAGE CONNECTION
NO. DELAY RANGE ADJUSTMENT VOLTAGE HZ AMPS. DROP DIAGRAM
32393 off delay 2 min. fixed 24 VAC 50/60 1 2 at 1 amp. 1 32377 off delay/ 6 sec...10 min. dial 24 VAC 50/60 6 2 at 6 amp. 2 or 3
32378 off delay/ 6 sec...10 min. dial 120 VAC 50/60 10 2.1 at 10 amp. 2 or 3
32379 off delay/ 6 sec...10 min. dial 230 VAC 50/60 10 5 at 10 amp. 2 or 3
interval
interval
interval