Mars 17006 User Manual

GE Relays
®
6
5
2
4
WIRING DIAGRAMS
SPST-NO
2
5
1
6
4
SPDT
RED
BLUE
RED
BLUE
YELLOW
BLACK
BLUEBLUE
RED
M
ODELS FA32, FC5, FC7
SINGLE-POLE, SINGLE THROW,
ISOLATED COIL
M
ODELS FB32, FD5, FD7
SINGLE-POLE, DOUBLE-THROW
ISOLATED COIL
COIL CHARACTERISTICS: INRUSH - 10 VA. SEALED IN CURRENT - 6 VA.
MARS SERIES 190
Totally Enclosed Switching Relays
Features:
Replaces GE, Honeywell, WR/Essex/RBM, White-Rodgers, etc.
COMPONENT
17015
MARS
NO.
17015 17016
17018
17019
17020
† S.P.D.T relays may be used on S.P.S.T. applications by eliminating use of yellow lead for normally open applications or eliminating use of black lead for normally
losed applications.
c
GE NO.
3ARR4 FA32 24 16 in. 3ARR4 FC7 120 SPST 1-1/2 18 55 6 in. 3ARR4 FB32 24 16 in. 3ARR4 FD7 120 SPDT 1-1/2 3/4 18 55 35 6 in. 3ARR4 FD5 240 6 in.
Cross Reference Information
WHITE-RODGERS MARS HONEYWELL MARS WHITE-RODGERS MARS
NO. REPLACEMENT NO. REPLACEMENT NO. REPLACEMENT
90-120 17015 R8225A 17018 8A04-1 17018 90-121 17016 R8225B 17015 90-122 17017 90-123 17018 90-124 17019 90-125 17020
COIL
VOLTAGE
• Designed for standard conduit box mounting for remote control of air conditioning and heating systems and remote power switching of
otors, power tools, fans and blowers.
m
Schematic
• Totally enclosed with heavy, impact resistant phenolic cover Non-positional
• Color-coded lead wires
• UL and CSA listings available
CONTACT
ARRANGEMENT
MAX. HP @ 240V
N.O. N.C. N.O. N.C.
F.L.A.
LOCKED MOTOR AMPS
LEAD
LENGTH
To replace relays w/quick-connect terminal use our relays in conjunction w/93001 QC-6 Kit.
MARS
NO.
17001 17002 17004 17006 93001
GE
CAT. NO.
3ARR4 A32 24 18 55 SPST-NO 3ARR4 CA32 24 3ARR4 CA7 120 18 55 35 SPDT 3ARR4 CA5 240 QC-6
Cross Reference To WR/Essex/RBM
WR/ESSEX MARS NO. REPLACEMENT
NO. REPLACEMENT 90-104 17001
90-100 17004 90-105 17002 90-101 17004 90-106 17002 90-102 17006 90-107 17004 90-103 17006 90-108 17006
Coil Data: 24-240 VAC @ 50/60 Hz; 10 VA Max. Coil Data: 24-240 VAC @ 50/60 Hz; 10 VA Max.
C-34
inrush; 6 VA Max. Sealed inrush; 6 VA Max. Sealed
The largest selection of motors, components, and accessories for the HVAC/R Industry
Switching and Shunt Relays
• MARS 17001—Economical replacement for SPST relays with 24 volt coil
• Reduce inventory on 3ARR4 relays. Four magnetic line relays now replace over 200 different models. SPDT relays will replace both single pole single throw and single pole double throw models
• Used for remote control of heating and air conditioning systems and remote power switching of motors, power tools, fans and blowers on GE, Day & Night, Carrier, York, Bryant,
17001
COIL
VOLTAGE
WR/ESSEX MARS
American Standard, Lennox, etc.
• Purchase of 93001 QC-6 Kit converts screw-on to push-on type terminals for even more replacements
• UL and CSA listings available
F.L.A.
LOCKED MOTOR AMPS
N.O. CONTACTS N.C. CONTACTS
93001
QC-6 KIT
CONTACT
ARRANGEMENT
Loading...