Azor is a wireless communications system that can be mounted on a vehicle. Azor allows remote operation of
integrated components located on the same machinery. The system consists of 1 gateway ME1 and 2 fobs MM1.
The gateway connects to the CAN bus on the machinery. It is advantageous if the machinery includes a user
interface to program settings on the gateway.
The fobs communicate to a Blue Tooth radio with integrated antenna inside the gateway. Individual buttons send
uniquely numbered messages onto the CAN Bus. New fobs can be paired with the system in the field.
Figure 1 Azor System Components
07_MM1_ME1_User Manual.docx
![](/html/2e/2ed0/2ed02311583c1d4cb5b66d4bf3288866406316cae36581cf09e9bd5875e77fb8/bg2.png)
MM1 / ME1 User Manual
03 Allgemeine Produktbeschreibung
Installation
Carefully remove the components from the box. Use M6 Button head screws to mount the gateway onto the
machine. Connect the 8-pin Deutch connector to the gateway. Be sure that the lines are unpowered while making
the connection. Pin 1 is top left and pin 8 is bottom left in Figure 2 Gateway Connector.
Figure 2 Gateway Connector
Figure 3 Deutch Connector Pin Designations
Be sure to mount the gateway in a location that does not interfere with the Blue Tooth wireless communications.
Metal should not be located between the internal antenna and locations where the operator will be pressing the
fob buttons. (If the fob operator cannot see the gateway, the fob reception will be reduced.)
Setup
The gateway initially is accompanied by 2 fobs that are paired with the gateway. Power can be supplied to the
gateway from the vehicle through either the ELX pin or the Vbat Pin, or both. There are multiple operating modes
of the system, depending on the pins providing power and a few parameters.
Conditions for Modes of Operation
ELX Power
When the gateway power source is through the ELX pin, without Vbat present, the entire module is configured to
operate continuously in the normal mode. No software modifications are required.