Dear Owner, Congratulations! Thank you for pur chasing this new heater by Marley Engineered Products. You have made a wise investment select-
ing the highest quality product in the heating industry. Please carefully read the installation and maintenance instructions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the industry’s leader in design, manufacturing, quality and service.
... The Employees of Marley Engineered Products
SAVE THESE INSTRUCTIONS
Read Carefully - This Instruction Sheet Contains Vital
Information For The Proper Assembly, Set-Up And Efficient Operation Of The Heater. Carefully Read The Manual Before Assembly, Operation, Or Cleaning Of The Heater. Failure To Adhere To The Instructions Could Result In Fire, Electrical Shock, Property Damage, Serious Personal Injury, Or Death. Save These Instructions And Review Frequently For Continuing Safe Operation And Instructing Future Users.
1. To prevent a possible electrical shock, disconnect all power coming to heater at main service panel before wiring or servicing.
2. All wiring must be in accordance with the National and Local Electrical Codes and the heater must be grounded as a precaution against possible electrical shock.
3. Verify the power supply voltage coming to the heater matches the ratings printed on the heater nameplate before energizing.
4. This heater is NOT suitable for use in hazardous locations as described by the National Fire Protection Association (NFPA). This heater has hot and arcing or sparking parts inside. Do NOT use in areas where gasoline, paint or other flammable liquids are used or stored.
5. This heater is intended to provide temporary, supplemental localized heat only in non-residential locations. The heater is intended for use on the floor only. Do NOT place heater on surface where is could fall or tip over.
6. Heater element operates at very hot temperatures. Do NOT place heater near combustibles and DO NOT place combustibles in the radiation path in front of the heater. Keep all combustibles at least five (5) feet from front of heater.
7. Heater is designed and intended for use as illustrated in this instruction sheet only. Do not position or use heater in any other manner.
8. This heater is hot when in use. To avoid burns, do NOT let bare skin touch hot surfaces. Keep combustible materials, such as furniture and papers at least 5 feet from the front of the heater.
9. DO NOT LEAVE HEATER UNATTENDED WHILE IN OPERATION.
10.Always disconnect heater when not in use.
11.Do NOT use outdoors in areas subject to wind.
12.Connect to properly grounded outlets or building ground.
13.This heater has hot surfaces. Do NOT use it in areas where gasoline, paint or flammable liquids are used or stored.
14.Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
15.In order to prevent equipment damage, protect with a ground fault device such as Marley Engineered Products WMGF240 for 240V heaters and WMGF480 for 480V heaters.
WARNING
!
WIRING
1. Use heater only at the voltage specified on the nameplate.
2. The heater connection points are located in the gasketed
terminal enclosure. To remove cover, remove screw(s) on the cover. Remove the cover to expose wiring connection points.
3. A green ground terminal is provided in the bottom of the
enclosure. The ground wire should be connected before other connections are made.
4. Use type "SO" or equal cord. Refer to Table 1 for proper
cord gage and number of conductors.
OPTIONAL ACCESSORIES
Marley Engineered Products L series radiant heaters can be
field modified by adding optional kits.
Cord Kits
Cord kits consist of 25 feet of 90°C cable and a right angle cord fitting which can connect directly to the heater terminal box or disconnect switch (if used). See instruction sheet 5200-2647-### for details
Plugs
Single and three phase with ground. Available in nonlocking and locking. See Table 1.
Ground Fault Kits
WMGF240 series kit mounts to wall that de-energizes the heater prior to element failure. See instruction sheet 5200-2652-###.
ELECRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property damage. Heater must be effectively grounded in accordance with the National Electrical Code, NFPA 70. All electrical wiring must be done by a qualified person in accor­dance with National Electrical Code (NEC) and meet all state and local regulations.
a
WARNING
2
Table 1 - Hand Carry Portable- L Series
Cord Locking Non-Locking
Model
Wattage Volts Amps Guage Cord Set Plug Set Plug Set
L1511B 1500 120 12.5 See Note See Note See Note
Note: This hand carry model includes cord and standard 3-prong gounded plug.
L2081B 208 9.6 14/3 CS25143 LPS25124 NPS25650 L2021B 240 8.3 14/3 CS25143 LPS25124 NPS25650 L2071B 2000 277 7.2 14/3 CS25143 LPS25124 N/A L2041B 480 4.2 14/3 CS25143 LPS25104 N/A L2061B 600 3.3 14/3 CS25143 LPS25083 N/A
L4581B 208 21.6 12/3 CS25123 LPS25103 NPS25650 L4521B 240 18.8 12/3 CS25123 LPS25124 NPS25650 L4571B 4500 277 15.9 14/3 CS25143 LPS25124 N/A L4541B 480 9.4 14/3 CS25143 LPS25104 N/A L4561B 600 7.5 14/3 CS25143 LPS25083 N/A
!