Thermostats and Controls
THERMOSTATS
&$! & (!&
& ! ! & & & & ""
-;376 Triac: Silent Operation Electronic Switch Triac: Silent Operation Microprocessor
&?8/ 12.5A Resistive 2 wire SPST 15 A Resistive 4 wire DPST 16.7A Resistive 2 wire SPST 16.7 A Resistive 4 wire DPST
)+;; $+;361 Minimum: 2 amp load No minimum load Minimum: 2 amp load No minimum load
( 1500 watts n/a 2000 watts n/a
( n/a n/a n/a 3000 watts
( 3000 watts 3600 watts 4000 watts 4000 watts
( n/a n/a n/a n/a
"347; <;? No No No No
$+61/ @ 40ºF to 85ºF 40ºF to 85ºF 40ºF to 85ºF 40ºF to 85ºF
300/9/6;3+4 Accuracy: Within +/- 0.27ºF Accuracy: Within 1ºF of setpoint Accuracy: Within +/- 0.27ºF Accuracy: Within 1ºF of setpoint
/+;<9/:
Digital, non-programmable
12.5amp model delivers exceptional accuracy. Ideal for
radiant ceiling panels, and
baseboard. Not for fan-forced
heaters.
Digital, non-programmable
model delivers exceptional
accuracy. Ideal for radiant
ceiling panels, and base-
board. Can be used for fan-
forced heaters..
Digital, programmable high capacity model delivers exceptional
accuracy. Ideal for radiant ceiling
panels, and baseboard. Can be
used for fan-forced heaters and re-
sistive loads.
Digital, programmable
model delivers exceptional
accuracy. Ideal for radiant
ceiling panels, and base-
board. Can be used for fan-
forced heaters.
THERMOSTATS
&$! & !) (!&
t To
t To
c
c
e
e
j
j
b
b
u
u
S
S
Av
Av
k
k
c
c
o
o
t
St
S
& ! ! & & & &
-;376 Electronic Switch Electronic Switch Electronic Switch Microprocessor
&?8/ 24 volt .015 -1.0A @ 30V 2-wire 24 volt .015 -1.0A @ 30V 2-wire 24 volt .015 -1.0A @ 30V 5-wire Wall thermistor
)+;; $+;361
( n/a n/a n/a 22A
( n/a n/a n/a 22A
( n/a n/a n/a 22A
( n/a n/a n/a 19A
"347; <;? 24VAC 24VAC 24VAC n/a
$+61/ @ 40ºF to 90ºF 40ºF to 90ºF 40ºF to 90ºF 40ºF to 90ºF
300/9/6;3+4 Accuracy: Within 1ºF of setpoint Accuracy: Within 1ºF of setpoint Accuracy: Within 1ºF of set Accuracy Within 1ºF of setpoint
/+;<9/:
Digital, non-programmable Digital, non-programmable
24 volt "Round" model de- 24 volt "Round" model de-
livers exceptional livers exceptional and cool thermostat. One
accuracy. (Heat Only) accuracy. (Heat and Cool) touch temperature control
Digital, 24volt programma-
ble 2 stage 5-7 wire heat
with exceptional accuracy.
Ideal for plenum heaters,
and HVAC systems.
Proportional and Integral
non-programmable elec-
tronic room sensor thermo-
stat with set point capability,
providing exceptional accu-
racy. Transmits actual tem-
perature to a LTR relay.
a
a
b
b
i
li
l
i
i
y
t
i
ity
l
l
i
i
2 QMark Heating Products www.qmarkmep.com
T
H
E
R
M
O
S
T
A
TS
&
!
-
;
3
76
&
?8/
58
$
+;
3
61
(
(
(
(
"
3
4
7;
<
;?
$
+6
1/
@
3
0
0
/
9
/
6
;
3
+4
/
+;
<
9/:
!
(
!
&
% )
S
nap
A
c
t
i
M
c
T
a
o
f
or
c
odel
h
e
re t
a
ns
t
i
o
ve
se
he
re us
r
uc
ts
S
P
ST
M
D
50ºF
e
c
s
nap
t
i
o
va
l
he
a
t
26 h
22A
22A
22A
18A
No
to
+
/
-
onomy
a
c
ed
in
n. G
ue.
I
d
e
rs
a
as
P
80ºF
5ºF
t
he
t
i
on t
a
pa
ood t
e
al
nd ba
D
on
os
r
f
t
or
P
ST
i
t
i
ve
O
FF
r
m
os
t
a
ts
y
pe
t
h
at
m
e
nt
h
e
r
m
os
t
at
r
a
di
a
nt
s
e
boa
r
d.
M
odel
T
t
L
S
M
he
se
h
e
r
m
a
r
ge
)
S
nap
A
c
P
ST
602W has
2
2A
2
2A
2
2A
1
8A
Y
es
125
45ºF
to
7
+
/
-
4ºF +
bi
-
m
e
t
al
os
t
a
ts
a
re s
k
nob a
l
l
a
d
j
us
t
m
t
i
VA
5ºF
s
ow
e
on
D
P
nap
e
nt.
P
ST
os
i
t
i
ve
O
FF
a
c
t
i
on
ns
e
t
i
ve.
f
or
e
a
sy
&
")
S
nap
S
P
el
M
M
6
02T
S
a
me
602W e
m
ount
t
a
m
ST
Y
45
per
PW
es
ºF
as
i
ng c
22A
22A
22A
18A
/
xc
pr
M
od
A
c
has
1
25VA
to
75ºF
-
4ºF
M
601W a
e
pt
over
oof
&
")
t
i
on
D
P
ST
P
os
i
t
i
ve
O
FF
nd
t
he
c
over
of
f
er
f
e
a
t
ur
e.
)
)
S
nap
A
c
t
i
S
P
M
ST
odel
M
612W has
Y
45ºF
Built-in heat anticipator assures closer control of room
temperature. These snap ac-
tion thermostats are more
sensitive that
on
D
P
ST
P
os
i
2
2A
2
2A
2
2A
1
8A
es
125
VA
to
75
ºF
+
/
- 2
1/
2ºF
t
i
ve
O
FF
T
H
E
R
M
O
ST
A
TS
& ! ! &" % & & )$ )$
-;376 Modulation (2 stage) Simultaneous switching (double ckt) Snap Action with Heat Anticipator Creep (Hydraulic) Action
&?8/ DPST SPST DPST SPST DPST
)+;; $+;361
( 22A 22A 22A 22A
( 22A 22A 22A 22A
( 22A 22A 22A 22A
( 18A 18A 18A na
"347; <;? Yes 125VA Yes 125VA Yes 125VA No
$+61/ @ 50ºF to 80ºF 50ºF to 80ºF 50ºF to 90ºF 40ºF to 85ºF
300/9/6;3+4 Accuracy: Within 3ºF of setpoint Accuracy: Within 3ºF of setpoint +/- 2 1/2ºF +/- 2ºF
/+;<9/:
(
!
&
One thermostat controls two sep- Simultaneous control of two
arate heating circuits and reduces heating loads. Used where the
input during light load periods. total load slightly exceeds capac-
Second stage activates when ity of a single switch, where two
temperature drops to approx. 1 thermostats are impractical. Both
1/2ºF below the first stage turn- switches are calibrated to operate
ON temperature. at approx. the same temperature.
Line voltage thermostat with
everything; Performance, reliabil-
ity, durability, and a large knob. heat as well as air tempera-
Built-in heat anticipation assures ture for ultimate control.
close temperature regulation. May cause slight radio or
Large knob for easy rotation. television interference in
Extra-sensitive element in
control knob senses radiant
outlying fringe areas.
www.qmarkmep.com QMark Heating Products 3
& & $!%& &% ! &$!%
& $ &*" % ! $ % ! $ & $ & $ & $ & $ & $
% $ % ! ) ) ) ) %"
$ % % $ %& $ &!
/+;/9 %/93/: %/93/: ) ) % $ $ # #&%
# ) ) % %
Refer to the See Note 1 See Note 2 See Note 3 See Note 4 See Note 6
Notes Section
where specified
&2/957:;+;: ,/47> +9/ /4/-;9763- >3;2 .313;+4 .3:84+?
TH110DPP Yes Yes The electronic No See model See model Yes
TH300024 Yes Yes thermostats are not No selection selection No
TH36004 Yes Yes recommended No chart. chart. Yes
TH400024 Yes Yes for this heater No Yes
TH522D1003 No No No No
&2/957:;+;: 43:;/. ,/47> +9/ 70 5/-2+63-+4 ;?8/ +6. >+6; ;7 -76;974 ;/58/9+;<9/ :/;;361 5+6<+44?
MS26 Yes Yes See model No See model See model Yes
MD26 Yes Yes selection chart for No selection selection Yes
M601W Yes Yes the recommended Yes chart. chart. Yes
M601TPW Yes Yes thermostat Yes Yes
M602W Yes Yes No Yes
M602TPW Yes Yes No Yes
M611W Yes Yes No Yes
M612W Yes Yes No Yes
M600S These stats are used when there are two elements to control. Two-stage operation
M600MTP and modulating type. Not normally used for above products.
T100 Yes Yes See model Yes See model See model Yes
T200 Yes Yes selection chart for No selection selection Yes
WR651 Yes Yes the recommended No chart. chart. Yes
WR661 Yes Yes thermostat No Yes
&2/957:;+;: ,/47> +9/ 579/ -755/9-3+4 6.<:;93+4 +6. 67; 6795+44? <:/. 76 9/:3./6;3+4 +8843-+;376:
WT11A No Yes See model No No No No
WT12A No Yes selection chart for No No No No
WR80 Yes Yes the recommended No No No No
WR80EP No No thermostat No No No No
&2/957:;+;: ,/47> +9/ 47> =74;+1/ ;7 =74;: %// 67;/ ,/47>
T8775A1009 Yes Yes No No No No No
T8775C1005 Yes Yes No No No No No
4/-;9763- ;9+6:0795/9 9/4+?: >3;2 ,<34; 36 ;9+6:0795/9
LTR1120
LTR208240
LTR1277
LTR2240
LT186F01 Yes Yes Yes Yes Yes Yes
H S S A
† For infrared type heaters, controls may be different for the type of element used. Contact Technical Services for recommendation.
Note 1: Electronic thermostats have amperage minimums and each model has different voltage requirements, please check catalog thermostat specifications.
Note 2: AWH, CWH, LFK Series models require the removal of the internal thermostat and wire wall thermostat in its place for proper fan operation. See THERMOSTAT MODEL
SELECTION (page 6) for specific thermostat.
Note 3: CWHDSAG and CWHDS Series models require the removal of the internal thermostat from unit. Wire wall thermostat for proper fan operation. See THERMOSTAT MODEL
SELECTION (page 6) for specific thermostats.
Note 4: CRA, SED, 1235, and 2400 Series models require the removal of the internal thermostat from unit. Wire wall thermostat for proper fan operation. See THERMOSTAT MODEL
SELECTION (page 6) for specific thermostats.
Note 5: Low voltage thermostats operate in conjuction with low voltage control systems using relays. Compatible with all standard 24V two wire thermostats.
Note 6: The 1100 watt units can use either single pole or double stats. The higher wattage, 1500watt, must use a double pole stat. (3 conductors from stat to heater) See website for further
details.
Note 7: CDF and EFF Series models require different thermostats based on internal wiring. Wire wall thermostat for proper fan operation. See THERMOSTAT MODEL
SELECTION (page 6) for specific thermostats. Can not use digital thermostat with this unit.
Note 8: Due to the complexity of wiring variations for remote wall thermostats with these products, we recommend that you contact Technical Services for assistance.
Note 9: Remove internal thermostat and wire wall thermostat in its place for proper fan operation.
Note 10: Thermostat wire to the two white wires on the heater.
Note 11: Wire wall thermostats as directed in the Installation Manual for proper fan operation.
&/-263-+4 %/9=3-/: 76;+-; 60795+;376
Phone: 800-452-4328
email: meptechsupport@marleymep.com
QMark Heating Products www.qmarkmep.com 4
& $ & $ & $ & $ ! ( &!$% $ & $ & & $% $ &
#
See note 7 See note 8 See note 8
' & ' & " ' %& !( " $ $ '%&$
' ' %" 44 %/93/: $ " $" $% +6.
'
& ' ' $" $%
&2/957:;+;: ,/47> +9/ /4/-;9763- >3;2 .313;+4 .3:84+?
See model Contact Yes No Contact Yes Yes † †
selection Tech Services No No Tech Services Yes Yes † †
chart. for assistance Yes No for assistance Yes Yes † †
Yes No Yes Yes † †
No Yes No No † †
&2/957:;+;: 43:;/. ,/47> +9/ 70 5/-2+63-+4 ;?8/ +6. >+6; ;7 -76;974 ;/58/9+;<9/ :/;;361 5+6<+44?
See model Contact No No Contact Yes Yes † †
selection Tech Services No No Tech Services Yes Yes † †
chart. for assistance Yes No for assistance Yes Yes † †
See model Contact Yes No Contact Yes Yes † †
selection Tech Services Yes No Tech Services Yes Yes † †
chart. for assistance No No for assistance Yes Yes † †
Yes No Yes Yes † †
Yes No Yes Yes † †
Yes No Yes Yes † †
Yes No Yes Yes † †
Yes No Yes Yes † †
No No Yes Yes † †
&2/957:;+;: ,/47> +9/ 579/ -755/9-3+4 6.<:;93+4 +6. 67; 6795+44? <:/. 76 9/:3./6;3+4 +8843-+;376:
Yes Contact Yes No Contact No Yes † †
No Tech Services Yes No Tech Services No Yes † †
Yes for assistance Yes No for assistance Yes Yes † †
No No No No No † †
&2/957:;+;: ,/47> +9/ 47> =74;+1/ ;7 =74;: %// 67;/ ,/47>
No No Yes No Yes Yes Yes † †
No No Yes Yes Yes Yes Yes † †
4/-;9763- ;9+6:0795/9 9/4+?: >3;2 ,<34; 36 ;9+6:0795/9
Yes Yes Yes No Yes Yes Yes † †
www.qmarkmep.com QMark Heating Products 5
& $!%& & ! % & !
From Notes 2, 3, 4 and 7 (see page 4)
& $ )
! & $!%& &
FRC1512 M601W
FRC3180 M601W
FRC4020 M601W
FRC4024 M601W
FRC4027 M601W
FRC3027 M601W
FRC4820 M601W
FRC4824 M601W
FRC4827 M601W
FRC40203 NA
FRC40243 NA
!& : See note 10, pg. 4.
SRA1012DSAG M601W
RA1512DSAG M601W
S
SRA1812DSAG M601W
SRA2024DSAG M601W
RA2027DSAG M601W
S
RA1527DSAG M601W
S
SRA2020DSAG M601W
!& : See note 10, pg. 4.
SRA1012DS M601W
SRA1512DS M601W
SRA1812DS M601W
SRA2024DS M601W
SRA2027DS M601W
SRA1527DS M601W
SRA2020DS M601W
!& : See note 10, pg. 4.
FRA1512 M602W
FRA1812 M602W
FRA4024 M602W
FRA4027 M602W
FRA3027 M602W
FRA4020 M602W
FRA4824 M602W
FRA4827 M602W
FRA4820 NA
!& : See note 10, pg. 4.
GFR1500 TH400024, M601W, M611W, T100, WR651
GFR2004 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
GFR2404 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
GFR1500T2 TH400024, M601W, M611W, T100, WR651
GFR2004T2 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
GFR2404T2 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
QFG1512IFM
QFG2024IFM
QFG2224IFM
QFG2228IF
QFG1512T2M
QFG2024T2M
QFG2224T2M
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
TH400024, M601W, M611W, T100, WR651
M602W, M612W, T200, WR661
TH400024, M601W, M611W, T100, WR651
& $ )
! & $!%& &
VFK151 M602W
VFK204 M602W
VFK304 M602W
VFK404 M602W
VFK484 M602W
!& : See note 10, pg. 4.
SED1012C TH400024, TH300024, M601W, M611W, T100, WR651
SED1024C TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
SED1512 TH400024, TH300024, M601W, M611W, T100, WR651
SED2024 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
ECP1024 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
ECP1524 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
CRA1512IF TH400024, M601W, M611W, T100, WR651
CRA2028IF M602W, M612W, T200, WR661
CRA2024IF TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
CRA2224IF TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
CRA1512T2 TH400024, M601W, M611W, T100, WR651
CRA2024T2 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
CRA2224T2 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
1235 TH400024, M601W, M611W, T100, WR651
1235P TH400024, M601W, M611W, T100, WR651
2435 TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
2435P TH110DPP, TH400024, TH300024, M602W, M612W, T200, WR661
FFCH548 MS26, M601W
FFCH542 TH400024, MS26, M601W
FFCH547 MS26, M601W
FFCH558 MS26, M601W
FFCH552 MS26, M601W
FFCH557 MS26, M601W
!& : See note 11, pg. 4.
QFF1500 TH400024, MS26, M601W
QFF3007 MS26, M601W
QFF4008 MS26, M601W
QFF4004 TH400024, MS26, M601W
QFF4007 MS26, M601W
QFF4804 MS26, M601W
QFF4807 MS26, M601W
!& : See note 12, pg. 4.
QCH1101 TH400024, TH300024, M601W, MS26
QCH1151 TH400024, M601W, MS26
QCH1202 TH400024, TH300024, M601W, MS26
QCH1207 TH400024, TH300024, M601W, MS26
!& : See note 12, pg. 4.
QMark Heating Products www.qmarkmep.com 6
%" &* ! &$!%
To
t To
t
li
c
c
e
e
j
j
b
b
a
k
k
A
Av
a
v
Su
Su
c
c
o
o
t
S
St
CAT. NO. VOLT AMPS
L R1120 120 22A
L R208240 208/240 22A
L R1277 277 19A
& ! ! )$ )$ " )& )& &$ % $ %
-;376 Snap Action Switch Snap Action Switch Positive snap action switch Electronic Relays
&?8/ SPST SPST SPDT Microprocessor base design
58 $+;361
(
(
(
(
"347; <;? Yes 125VA Yes 125VA Yes 125VA
$+61/ @ 40ºF to 90ºF 40ºF to 90ºF 40ºF to 110ºF
300/9/6;3+4 +/- 3ºF +/- 3ºF +/- 2 1/2ºF
/+;<9/:
Rugged design for garages,
factories, warehouses and sim-
ilar commercial and industrial
installations. The WR80 can
control several heaters by
using an external contactor.
25A
22A
22A
18A
25A
22A
22A
18A
This explosion proof room
thermostat is suitable for Class
1, Group D and Class II,
Groups E, F, and G locations.
The control has a SPDT output and
Nema 4X rated
25A n/a
25A
25A
22A
Nema 4X weatherproof enclosure.
can be used for heating or cooling
(ventilation) Multi-positional
mounting offers flexibility in new
or existing installations.
These electronic relays have been
designed for silent control of high
voltage resistive loads from a low
voltage control circuit. Inductive
motor loads can also be controlled
(120V to 240V only). Compatible
with 24V thermostats and accepts
analog signal of 0-10V DC.
The relays can be used with model
LT186F01 electronic room sensor,
providing proportional and inte-
gral control. Also can be tied to
building management systems.
li
i
i
b
ib
l
li
i
i
t
ty
y
%" &* ! &$!%
& ! ! &$ & & ) &
-;376 Dual Silent Relay
&?8/ 2 single pole switches.
)+;; $+;361 Resistive Inductive
( N/A
( 25A 1HP, 8.8A
( 25A 1HP, 8A
( N/A
"347; <;? Yes 125VA
$+61/ @ Can be operate in 20 to 140ºF
300/9/6;3+4 Accuracy: Within 1.5ºF of setpoint
/+;<9/:
www.qmarkmep.com QMark Heating Products 7
This dual level temperature
relay may be used to operate
two separate heating loads by
means of a single low voltage
thermostat. Relay is mounted
in an enclosure.
Enclosure protection for thermostats.
Material: Impact resistant poly-
carbonate. Clear. Dimensions
are: 7"L X 4.28"H X 2.75" D
Thermostat enclosure kits are de-
signed to protect the thermostat.
Circulating slots allow airflow
for proper operation. Guards are
lockable and a key is provided to
maintain security.
M600THW -White thermostat
cover with built-in thermome-
ter. For M600 Series stats.
M600THB - Beige thermostat
cover with built-in thermome-
ter. For M600 Series stats.
Minimum 50pcs
Allow 4 weeks.
- ZBR QSTAT 10/11 www.qmarkmep.com