Marley Engineered Products C2500, C1800, 1800, 2500 User Manual

Electric Baseboard Heaters
1800, 2500, C1800 & C2500 Series
WARNING
Installation & Maintenance Instructions
Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by a division of Marley
Engineered Products. You have made a wise investment selecting the highest quality product in the heat­ing industry. Please carefully read the installation and maintenance instructions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the industry’s leader in design, manufacturing, quality and service.
... The Employees of Marley Engineered Products
Read Carefully - This Instruction Sheet contains vital
information for the proper installation, use, and efficient operation of the heater. Carefully read the manual before installation, operation, or cleaning of the heater. Failure to adhere to the instructions could result in fire, electric shock, death, serious personal injury, or property damage. Save these instructions and review frequently for continu­ing safe operation and instructing future users.
1. Keep all electrical cords, foam filled articles, drapes, bed­ding, and other household furnishings away from contact with heater. It is recommended all items be kept a minimum of six (6") inches (152mm) from heater.
2. Do not install baseboard heater below electrical convenience receptacles (outlets).
3. Do not install baseboard heater against vinyl wallpaper, paperboard or low density fiberboard surface. Do not install vinyl drapes or vinyl blinds above heater.
4. Do not recess heater in wall.
5. The installation must comply with applicable Local and National Electrical Codes and utility requirements.
6. Do not remove or by-pass thermal cutout.
7. To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater.
8. Personal injury or death could result from electric shock. Disconnect all power to heater at main panel before attempting to install or service this heater.
9. Supply voltage must be the same as heater voltage. Check heater nameplate and supply voltage before energizing.
10. When using RSA Transformer Relay Accessory, supply wiring must be suitable for 90°C.
!
1
File #E37116
This Heater is designed to provide years of efficient, trouble free operation as a primary or supplementary heat source for residen­tial and commercial applications. Baseboard heaters must be thermostatically controlled for efficient, safe operation. A thermo­stat is not provided with this heater. However, a single or double
pole thermostat accessory is available for installation into this heater at your place of purchase, or the heater may be connect­ed to any suitable wall mounted thermostat that will meet the elec­trical load requirements. Installation or use of this product in any manner not described herein will void the warranty and could result in injury, damage to property, or permanent damage to heater.
UNPACKING HEATER
Check heater to make sure it has not been damaged in shipping. Do not install or attempt to operate the heater if damaged. Return to place of purchase or file claim with freight carrier.
NOTICE T O OWNERS
Certain fabrics discolor in time from indirect sunlight and normal room temperature - mostly organic and synthetic material. They will discolor more rapidly when exposed to direct sunlight and warm currents. Hang drapes to provide minimum of 2 in.(51mm) air space between heater front and nearest drape fold as shown in Example 1 Figure 1, or 6 in.(153mm) airspace between top of heater and bottom of drapes as shown in Example 2, Figure 1. Allow minimum clearance of 1 in. (26mm) from drapes to ceiling and to top of floor covering to permit air circulation as shown in Example 1, Figure 1.
INSTALLATION
FLOORS & CARPETING: Heaters may be mounted directly on any floor surface, including carpeting. Where wall-to-wall carpets are installed after the base­board installation, the carpeting can be run up to the front and around the heater body, providing it does not obstruct air flow. (Maximum 3/4” (19mm) thick).
1. Remove wiring compartment cover at end of heater where power supply cable is to enter. Determine desired mounting location (Figure 2), position heater to wall as intended and mark wall (or floor) at location where power supply is to enter heater.
Heater Ampere Rating.
Total Amps
Minimum
AWG. Wire Size
(Copper)
Circuit Breaker
or Fuse Size
0 thru 12
12.1 thru 16
16.1 thru 24
#14 #12 #10
15 amp 20 amp 30 amp
NET VOLUMES OF WIRING COMPARTMENT
DESCRIPTION
CUBIC
INCHES
CUBIC
CENTIMETERS Heater Only (Each Wiring Compartment) Heater W/SP Thermostat Heater W/DP Thermostat Heater W/Heat-Cool Switch Receptacle Heater W/Duplex Receptacle Heater W/DP Disconnect Switch Heater W/Power Relay Heater W/Transformer Relay
14.96
11.18
11.18
9.51
11.18
11.18
10.76
2.93
241 180 180 153 180 180 174
47
Figure. 1 Position Drapery near Heater
2
Figure. 2
Residential
Model No.
2512 *
25126 *
2513 * 2514 * 2515 * 2516 *
2502 *
25026 *
2503 * 2504 * 2505 * 2506 * 2507 * 2508 *
25008 *
2542 *
25426 *
2543 * 2544 * 2545 * 2546 * 2547 * 2548 *
25408 *
2572 *
25726 *
2573 * 2574 * 2575 * 2576 * 2577 * 2578 *
25708 * 25326 *
2533 * 2534 * 2535 * 2536 * 2537 * 2538 *
25308 *
2530 * 2564 *
2565 * 2566 * 2567 * 2568 *
25608 *
2560 *
-
C25126 *
C2513 * C2514 * C2515 * C2516 *
-
C25026 *
C2503 * C2504 * C2505 * C2506 * C2507 * C2508 *
C25008 *
-
C25426 *
C2543 * C2544 * C2545 * C2546 * C2547 * C2548 *
C25408 *
-
C25726 *
C2573 * C2574 * C2575 * C2576 * C2577 * C2578 *
C25708 * C25326 *
C2533 * C2534 * C2535 * C2536 * C2537 * C2538 *
C25308 *
C2530 * C2564 *
C2565 * C2566 * C2567 * C2568 *
C25608 *
C2560 *
3.3
4.2
6.3
8.3
10.4
12.5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.9
2.4
3.6
4.8
6.0
7.2
9.6
8.4
12.0
1.4
1.8
2.7
3.6
4.5
5.4
6.3
7.2
8.7
1.1
1.4
2.0
2.7
3.4
4.1
4.7
5.4
6.8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.7
2.1
3.1
4.2
5.2
6.3
7.3
8.3
10.4
1.2
1.6
2.4
3.1
3.9
4.7
5.5
6.3
7.5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.4
1.8
2.7
3.6
4.5
5.4
6.3
7.2
9.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Commercial
Model No.
120 Volt
208 Volt 240 Volt
277 Volt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.4
2.2
2.9
3.6
4.3
5.0
5.8
7.2
7.2
-
-
-
-
-
-
-
347 Volt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.7
2.1
2.5
2.9
3.3
4.2
4.2
600 Volt
* Followed by WC or NWC suffix