Congratulations! Thank you for purchasing this new heater manufactured by a division of Marley Engineered Products. You have made a wise investment selecting the highest quality product in the heat­ing industry. Please carefully read and follow the installation and maintenance directions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the industry’s leader in design, manufacturing, quality and service.
... The Employees of Marley Engineered Products
Installation & Maintenance Instructions
!
1
Read Carefully - These instructions contain vital infor-
mation for the proper installation, use and efficient opera­tion of the heater. Carefully read these instructions before installation, operation, or cleaning of the heater. Failure to adhere to the instructions could result in fire, electric shock, serious personal injury, death or property damage. Save these instructions and review frequently for continu­ing safe operation and instruction of future users.
1. Connect to properly grounded outlets only.
2. Check heater voltage and amperage on back of heater to make sure it agrees with the electric service supplied.
3. Ground fault circuit protection is required if heater is used in damp areas such as basements or garages. This heater is not suitable for use in wet or very humid locations.
4. Do not use outdoors.
5. Never locate heater where it may fall into a bathtub or other water container.
6. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire, or damage the heater.
7. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked. Clean as often as
necessary to prevent dust from clogging the grilles or ele­ment fins. Keep all electrical cords, drapes, paper, plastics and other combustibles away from heater.
8. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, etc. T o prevent entanglement or damage, route cord away from high traffic areas.
9. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored
10. If this heater or its power cord become damaged or malfunc­tion in any way, unplug heater, discontinue use, and have unit repaired by a reputable repair service.
11. Heater is hot when in use. To avoid burns do not let bare skin touch hot surfaces. Use handle to move heater.
12. Do not use an extension cord with this heater. Do not cut off plug and wire heater directly.
13. Extreme caution is necessary when heater is used by or near children or invalids and whenever heater is left operating unattended
402A
482A & 562A
File #E152700
PLUG TYPE 20 amp 240 V NEMA #6-20P
PLUG TYPE 30 amp 240 V NEMA #6-30P
SA VE THESE INSTR UCTIONS
GENERAL
Prior to operating heater, make sure the electrical outlet is of the configuration and capacity appropriate for the heater. See outlet configuration on front page of manual. No adapter is available for this blade configuration and none should be used. The outlet pro­vided must be a 240 volts grounded type. When properly installed, it provides a ground connection through the cord of the heater to protect the operator from electric shock. In workshops, locate heater away from sources of wood dust.
FLOOR APPLICATION
The heater is for floor mounting. Place the heater on floor or other flat surface and insert plug into the proper wall outlet.
HEATER OPERATION
Set thermostat to its full counterclockwise position. Plug the unit into a properly grounded 240 V outlet. (#6-20 for model 402A, #6­30 for models 482A & 562A). Set the thermostat to the farthest clockwise position. The fan should come on and the unit will start heating the room. When the room reaches comfort level, turn the thermostat counterclockwise until the heater turns off. The heater will cycle automatically around this preset temperature. To increase temperature, turn the thermostat knob clockwise. To lower temperature, turn the thermostat counterclockwise.
CONTINUOUS FAN OPERATION
(MODEL 562A ONLY)
To activate the continuous fan feature, set rocker switch to “ON” position. The elements will continue to cycle on the thermostat set­ting. For no heat, turn thermostat to full counterclockwise position. With fan in “AUTO” position, fan will cycle with the thermostat.
CLEANING AND STORAGE
Turn thermostat off and remove plug from electrical outlet before cleaning heater. Use a soft cloth for dusting. For cleaning, use only a damp rag and non-abrasive dish detergent. Do not use abrasive chemical cleaners as these may harm the finish. If heater is used in very dusty location, use a vacuum cleaner dust brush to remove dust and other foreign material from the grilles. Always unplug cord and wrap around heater handle when not in use. Move heater to a safe location for storage.
SERVICE
This heater does not require any routine maintenance other than occasional cleaning to prevent clogging of intake grille opening. To clean air intake grille, use vacuum with brush attachment or high pressure air. The motor is permanently lubricated. Do not operate the heater with a damaged cord or plug or if the heater malfunctions or has been damaged in any manner. Return heater to authorized service facility for examination, electrical, or mechanical adjust­ment, or repair. Call the toll free number listed for assistance in locating the Marley authorized service center in your area.
WARNING
!
BE CAREFUL NOT TO DIRECT THE AIRSTREAM AT DRAPERIES, FURNITURE, OR OTHER OBJECTS THAT COULD BE DAMAGED BY HEAT.
DO NOT PLACE THE HEATER WHERE A SMALL CHILD MAY FALL OVER THE HEATER.
DO NOT PLACE THE HEATER WHERE THE POWER CORD MAY BE WALKED ON, TRIPPED OVER, OR OTHER­WISE SUBJECTED TO HARD USAGE.
MODEL
AMPS
DATE
VOLTS
PH Hz
482A WK/YY
240/208
1
60
20.0/17.3
NAMEPLATE
5200-2274-003 ECR35081 12/01
How to order repair parts: In order to obtain any needed repair or replacement parts, war­ranty service or technical information, please contact the Marley Engineered Products Service Center toll-free by calling 1-800­642-HEAT. When ordering replacement parts, always give the information listed as follows:
1. The Part Number
2. The Model Number
3. The Part Description
4. Date of Manufacture
WARNING
!
OPERATION OF THE SAFETY THERMALLIMITCONTROLINDI­CATES THE HEA TER HAS BEEN SUBJECTED TO SOME ABNOR­MAL CONDITIONS. IT IS RECOMMENDED THATTHE HEA TER BE CHECKED BY A REPUTABLE ELECTRICIAN OR REPAIR SER­VICE TO INSURE THE HEATER HAS NOT BEEN DAMAGED.
MADE IN TAIWAN FOR:
2
LIMITED WARRANTY
All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the con­nected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in viola­tion of the product’s installation instructions. All claims for war­ranty work must be accompanied by proof of the date of installa­tion.
The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to Marley Engineered Products Service Center. Within the limitations of this warranty, inoperative units should be returned to the nearest Marley autho­rized service center or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products.
THE ABOVE WARRANTIES ARE IN LIEU OF ALLOTHER WAR­RANTIES EXPRESSED OR IMPLIED. AND ALL IMPLIED WAR­RANTIES OF MERCHANTABILITY AND FITNESS FOR A PAR­TICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGI­NEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSE­QUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For the address of your nearest authorized service center, con­tact Marley Engineered Products in Bennettsville, SC, at 1-800­642-4328. Merchandise returned to the factory must be accom­panied by a return authorization and service identification tag, both available from Marley Engineered Products. When request­ing return authorization, include all catalog numbers shown on the products.
2F68