Factory wired for 240/208 V supply, field convertible for 120 V.
5”
127 mm)
(
(63 mm)
(25 mm)
(89 mm)
21”
(532 mm)
-1/2”
3
89 mm)
(
5”
(127 mm)
IMPORTANT INSTRUCTIONS
WARNING
WHEN USING ELECTRIC APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:
1. Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, etc. and
curtains at least 3 feet (0.9 m) from the front of the heater.
3. Extreme caution is necessary when any heater is used by or
near children or invalids and whenever the heater is left
operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a reputable electrician before using.
5. Do not use outdoors.
6. To disconnect heater, turn controls to off, and turn off power
to heater circuit at main disconnect panel.
7. Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock, fire,
or damage to the heater.
!
8. To prevent a possible fire, do not block air intake or exhaust
in any manner.
9. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint, or flammable liquids
are used or stored.
10. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
11. This heater is intended for comfort heating applications and
not intended for use in special environments. Do not use in
damp or wet locations such as marine or greenhouse or in
areas where corrosive or chemical agents are present.
12. When installing, see INSTALLATION INSTRUCTIONS for
additional warnings and precautions.
13. For safe and efficient operation, and to extend the life of your
heater, keep your heater clean - See MAINTENANCE
INSTRUCTIONS.
ECR 3944910/125200-11119-000
SAVE THESE INSTRUCTIONS
INSTALLATION
INSTRUCTIONS
To prevent a possible fire, injury to persons or damage to the
heater, adhere to the following:
1. Disconnect all power coming to heater at main service
panel before wiring or servicing.
2. All wiring procedures and connections must be in accordance with the National and Local Codes having jurisdiction and the heater must be grounded.
3. Power supply must enter through the prepunched hole in
the wiring compartment.
4. Verify the power supply voltage coming to heater matches
the ratings as shown on the heater nameplate.
CAUTION: ENERGIZING HEATER AT A VOLTAGE GREATER
THAN THE VOLTAGE PRINTED ON THE NAMEPLATE WILL
DAMAGE THE HEATER AND VOID THE WARRANTY AND
COULD CAUSE A FIRE.
5. CAUTION - High temperature, risk of fire, keep electrical
cords, drapery, furnishings, and other combustibles at least
3 feet (0.9 m) from front of heater. Do not install heater
behind doors, below towel racks, or in an area where it is
subject to being blocked by furniture, curtains or storage
materials. Hot air from the heater may damage certain fabrics and plastics.
6. To reduce the risk of fire, do not store or use gasoline or
other flammable vapors and liquids in the vicinity of the
heater.
7. This heater is to be mounted horizontally on the wall only.
DO NOT install vertically.
8. The following minimum clearances must be maintained:
Bottom of heater to floor - 18” (457 mm).
Top of heater to ceiling - 12” (305 mm)
Ends of heater may be next to adjacent wall
9. Do not operate the heater without the grille installed.
10. Do not use this heater for dry out as the paint, plaster, sawdust and drywall sanding dust will permanently damage the
heater and must be kept out of the heater.
General
The HT500 Utility Heater is designed for horizontal wall mounting only. The built-in thermostat allows for adjustment of the heat
output from 40˚ to 70˚ F. The heater is factory wired for use at
240/208 volts but can be re-wired for use at 120 volts.
Ceiling
Heater
End
View
Floor
12”min.
(304mm)
18”min.
(456mm)
Mounting
1. Remove the grille cover by removing the 2 screws on the
front of the cover.
2. Position the heater on wall at desired mounting location
maintaining the minimum clearances, see Figure 1.
NOTE: The heater MUST be mounted horizontally to allow air
flow freely upward through the heating element. Thermostat can
be located towards either end of heater.
3. Securely fasten the heater to the wall with screws or bolts
using the four (4) pre-drilled holes in the heater back (Figure 2)
21”
(532mm)
.203”diameter holes
16”
(405mm)
(5mm)
.75”
1
44m m)
(
51m m)
(
2”
5”
(127mm)
Figure 2: Mounting Dimensions
Wiring
1. Bring power supply cable to heater and install into heater
wiring compartment through the pre-punched 7/8” (22mm)
hole in the end of control box. Be sure to use cable clamp on
cable as required by the National Electric Code.
2. Connect the supply ground wire to the heater using the green
colored ground screw.
3. To operate the heater at 208 through 240 volts, connect
power supply wiring to heater wiring following the wiring diagram shown in Figure 3. do not use the white wire marked “n”
for wiring to 208 through 240 volts.
4. To operate the heater at 120 volts requires the heater to be
re-wired as shown in Figure 3 by connecting blue L2 lead
wire to wire connection of the other element blue lead wire
and thermostat blue lead wire. Remove the L2 wire marker.
Connect 120 volts to the black L1 lead and the white N lead.
See Figure 4.
5. Complete the installation by replacing the grille cover using 2
screws removed earlier and 4 additional screws from parts
bag. Remove thermostat knob from the parts bag and install.
Do not use white wire in 240 volt circuit
Element
Blue
Blue
To rewire for 120 volt
operation:
1. Connect Blue “L2”
Element
wire connection to
other element Blue
lead and thermostat
Blue lead. Remove
“L2” wire marker.
2. Connect 120 volts to
Black “L1” & White “N”.
To
240/
208 V
Supply
N
Black
L1
L2
Blue
White
T’Stat
Blue
Figure 3: Factory wired for 240/208 volt operation
1. Heater must be properly installed before operation.
2. Turn on the power supply to the heater.
3. Rotate the thermostat clockwise to the warmest setting. If the
air temperature is below 70˚F the heater should come on and
in a few moments the heating element will become warm. If
the air temperature is above 70˚F, the heater will not operate.
A check of the thermostat setting has to occur when the air
temperature is below 70˚F
4. The thermostat range is from 40˚F at full counterclockwise
position to 70˚F at full clockwise. Position thermostat at
desired location. Thermostat will automatically cycle the
heater on and off to maintain the desired temperature.
NOTE: The heater is designed to provide freeze protection and
the thermostat may allow the heater to come on at the lowest
setting if the space temperature drops below 40˚ F.
INSTRUCTIONS
It is important to keep this heater clean. Your heater will give you
years of service and comfort with only minimum care. To assure
efficient operation follow the simple instructions below.
ALL SERVICING BEYOND SIMPLE CLEANING THAT
REQUIRES DISASSEMBLY SHOULD BE PERFORMED BY
QUALIFIED SERVICE PERSONNEL.
TO REDUCE RISK OF FIRE AND ELECTRIC SHOCK OR
INJURY, DISCONNECT ALL POWER COMING TO HEATER
AT MAIN SERVICE PANEL AND CHECK THAT THE ELEMENT
IS COOL BEFORE SERVICING OR PERFORMING
MAINTENANCE.
User Cleaning Instructions:
1. After the heater has cooled, a vacuum cleaner with brush
attachment may be used to remove dust and lint from exterior
surfaces of the heater including the grille openings.
2. With a damp cloth, wipe dust and lint from grille and exterior
surfaces.
3. Return power to heater and check to make sure it is operating properly.
3
All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except
LIMITED WARRANTY
heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from
accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or
maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation.
The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to
Marley Engineered Products Service Center. Within the limitations of this warranty, inoperative units should be returned to the nearest Marley authorized service center
or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such
repair or replacement is the exclusive remedy available from Marley Engineered Products.
THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS
AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE
PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.
For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization,
include all catalog numbers shown on the products.
HOW TO OBTAIN WARRANTY SERVICE AND
WARRANTY PARTS PLUS GENERAL INFORMATION
1. Warranty Service or Parts1-800-642-4328
2. Purchase Replacement Parts1-800-654-3545
3. General Product Informationwww.marleymep.com
Note: When obtaining service always have the following:
1. Model number of the product
2. Date of manufacture
3. Part number or description
470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA