Marley C6012D, C6024D, C6027D, C7508D, C7512D Installation & Maintenance Instructions Manual

...
COVE HEATER
Patent Pending
Model D
Installation & Maintenance Instructions
WARNING
!
Read Carefully
prevent difficulties that might arise during installation of heaters. Studying the instructions first may save you con­siderable time and money later. Observe the following pro­cedures, and cut your mounting time to a minimum. TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK:
1. Disconnect all power coming to heater at main service panel before wiring or servicing.
2. All wiring must be in accordance with the National and Local Electrical Codes and the heater must be grounded.
3. Verify the power supply voltage coming to heater matches the ratings printed on the heater nameplate before energizing.
4. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces.
- These instructions are written to help you
FILE #E21609
5. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire,or damage to the heater.
6. Do not block air intakes or exhaust in any manner. Keep com­bustible materials, such as crates, drapes, etc., away from heater. Do not install behind door, furniture, towels, or boxes.
7. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
8. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
9. This heater is not approved for use in corrosive atmospheres such as marine, green house, or chemical storage areas.
CAUTION
1. THE HEATER MUST BE MOUNTED AT LEAST 6' (182.8 cm) or (1.83 m ) ABOVE THE FLOOR TO PREVENT ACCIDENTAL CONTACT.
2. TO PREVENT POSSIBLE OVERHEATING OR DAMAGE DUE TO OVERHEATING, REFER TO FIGURES 1 AND 4 FOR SIDE, TOP, AND BOTTOM CLEARANCE REQUIREMENTS.
!
GENERAL
When installing 2 or more heaters along one wall:
1. Mount heaters allowing adequate spacing between heaters as shown in Table 1.
2. Install optional RCCSPC Splice Plate (if desired) per instructions provided with RCCSPC.
When mounting heaters end to end add the “maximum allowable expansion” of each heater and provide that clearance from end to end of units. See Table 1.
Table 1
MAXIMUM ALLOWABLE MOUNTING SLOT
WATTS
450 600 750
900 1050 1200 1500 1800
EXPANSION DISTANCE (CTR-CTR)
1/8” (4mm)
1/4” (7mm) 1/2” (13mm) 3/4” (19mm) 7/8” (23mm)
1-1/8 (29mm) 1-3/8 (35mm)
1-1/2” (38mm)
27.75” (705mm)
40.75” (1,035mm)
52.75” (1,340mm)
64.75” (1,645mm)
76.75” (1,949mm)
87.75” (2,229mm)
111.75” (2,838mm)
125.75” (3,194mm)
SAVE THESE INSTRUCTIONS
MOUNTING THE HEATER
For 450 to 1200 Watt Heaters:
1. Select correct mounting distance from the ceiling material per Figure 1. Using Table 1, determine the center to center distance of the end wall brackets for the particular model (wattage) to be mounted. Divide this value by 2 to determine the approximate location to mount the center wall bracket. Mark these locations on the chosen wall. Locate a stud nearest the center wall bracket mark. Use this stud for the bracket location. (Disregard original mark mentioned above) Assemble end wall brackets as shown in Figure 3.
2. Using the template (provided), align the top of the template with the ceiling and the center of the pre-punched holes with the bracket marks on the wall. Choosing the proper ( end or middle) bracket location holes, mark the bracket pilot hole locations using the selected pre-punched holes provided on the template. With the fasteners provided, mount the assembled end wall brackets and center wall bracket to the wall. Using a tape measure, deter­mine the distance between the center (slot) of the left end wall bracket and the hook of the center wall bracket. Add 3-5/8 inches (92 mm) to this value and record it for center support bracket location on the cove heater.
3. Orient the cove heater face down on a protective flat surface. Using the value recorded in step 2, measure this distance from the left end of the cove heater and mark this location on the back surface of the panel. Slide the center support bracket to the marked position on the panel, aligning the center of the bracket with this mark.
4
” (102 mm) MIN. (DRY WALL CEILINGS)
6
” (152 mm) MIN. (LAY IN OR VINYL
CEILINGS OR PLASTIC MOLDING)
1
“ (25.4 mm) MIN. BETWEEN BOTTOM
OF HEATER AND ANY FABRIC
6‘ MINIMUM (1.83 m) CLEARANCE TO FLOOR
CURTAINS
CEILING
WALL
FLOOR
MOUNTING RESTRICTIONS
}
4” (102 mm)(DRY WALL CEILINGS) 6” (152 mm) LAY IN OR VINYL CEILINGS OR PLASTIC MOLDING)
BACK VIEW
MOUNTING SLOTS
MOUNTING BRACKETS
34” TO 132”
(0.86 M to 3.35 M)
CEILING
WALL
3”
2”
TOP VIEW
4-3/16“ (106.4 mm)
1-1/2” (38.1 mm)
HEATERS TO BE MOUNTED AT LEAST SIX (6) FEET (1.83 M) FROM THE FLOOR.
MINIMUM CLEARANCES:
• 4” (102 mm) MIN. TO DRY WALL CEILING.
• 6” (152 mm) MIN. TO LAY-IN OR VINYL CEILING OR PLASTIC MOLDING.
CEILING
2-1/2”
13/16”
Figure 1
HEATE R
HEATE R
4”
4”
MOUNTING THE HEATER (Continued)
4. To mount cove heater, attach center support bracket to the center wall bracket by tilting the heater back and allowing the upper slot
to fall onto the bracket hook per Figure 2. Attach the junction
boxes to the end wall brackets in a similar manor. Bring the cove
heater forward to lock into place. For 1500 to 1800 Watt Heaters: The 1500 & 1800 watt cove heaters require the additional support of
(2) center wall brackets due to the extra length. The mounting steps are similar to the 450 to 1200 watt cove heater with the following exceptions:
1. After the approximate center location between the end wall brack-
ets has been determined, measure 30 inches (762 mm) on each side of this location to determine the approximate location to mount the center wall brackets. Locate a stud nearest each mark. Use these studs for the center wall bracket locations. (Disregard original 30 inch location marks)
2. Using the provided template, align the top of the template with the
ceiling and the center of the pre-punched holes with the bracket marks on the wall. Choosing the proper bracket location holes, mark the bracket pilot hole locations using the selected pre­punched holes provided on the template. With the fasteners pro­vided, mount the assembled end wall brackets and center wall brackets to the wall. Measure the distance between the center (slot) of the left end wall bracket and the hook of the left center wall bracket. Add 3-5/8 inches (92 mm) to this (left end) value and record it for the left center support bracket location on the cove heater. Determine the distance between the center of the right end wall bracket and the hook of the right center wall bracket. Add 3-5/8 inches (92 mm) to this (right end) value and record it for the right center support bracket placement on the cove heater.
3. Orient the cove heater face down on a protective flat surface.
Using the left end value recorded in step 2, measure this distance from the left end of the cove heater and mark this location on the back surface of the panel. Using the right end value recorded in step 2, measure this distance from the right end of the cove heater and mark this location on the back surface of the panel. Slide the center support brackets to the marked positions on the panel, aligning the center of the brackets with each mark.
4. To mount cove heater, attach center support brackets to the cen-
ter wall brackets by tilting the heater back and allowing the upper slot to fall onto the bracket hook per Figure 2. Attach the junction boxes to the end wall brackets in a similar manor. Bring the cove
heater forward to lock into place.
5. The cove heater can be wired from either end of the heater.
Install a cable clamp (supplied by others) in one of the knockouts located in back of the junction boxes you plan to use. Insert the power supply cable through the cable clamp allowing approxi­mately 6” (152mm) of cable length to remain inside the box to facilitate wiring. Add at least 2 inches of cable loop between wall and knockout entering the junction box to allow for heater expan­sion.
ALIGN JUNCTION BOX SLOT WITH BRACKET HOOK
Figure 2
#10-16 X 1-1/2” LONG SCREWS
JUNCTIONBOX
ELEMENT LEAD
Figure 3
MOUNTING HEATER
TO END BRACKET
ASSEMBLY
HEATER LOCKED IN POSITION ON END WALL BRACKET
END WALL
BRACKET ASSEMBLY
CENTER WALL BRACKET
CENTER SUPPORT BRACKET
CROSSOVER LEAD
END CAP
#8-18 X 1” LONG SCREWS
CUTAWAY SHOWING CENTER MOUNTING BRACKET DETAILS
CENTER SUPPORT BRACKET
BACK WRAP HEAT SHIELD
COVE HEATER FRONT PANEL
OP
T
LANGE
F
BACK WRAP
WIREWAY
Figure 4
6. Refer to wiring diagrams on next page.
7. Attach end caps (found in parts bag) as shown in Figure 3.
1. Heaters must be located so that the ends of each heater are 4 inches (102 mm) from side wall. See Figure 4.
2
INSTALLATION AT CORNER
Loading...