Unpacking, Placement and Ventilation,
Power Requirements, Operating States
Getting Started 4
Front-Panel Overview, Rear-Panel Overview,
Remote Control Overview
Quick Setup and Listen 11
Remote Control, Initial Connections
Factory-Default Settings 16
Inputs, Aux Output, Volume Control,
Power Management, Advanced
Specifications 17
enGliSh
about thiS document
This quick-start guide contains all the information you
will need to unpack and place your N
rest of your audio system, turn it on and have a first listen.
Before you attempt more extensive use of this sophisticated
preamplifier, you must read the full
is contained in the supplied USB memory stick. The User
Guide contains information about features, operations,
adjustments, alternate connections and networking that
will enhance your N
0
52’s operation and performance.
0
52, connect it to the
N052 User Guide
, which
NOTE: Within this quick-start guide, the term
“Controller” is used to refer to the N
chassis and the term “Preamplifier” is used to refer
to the N
used to refer to the dual-chassis combination.
0
52 Preamplifier chassis. The term “N052” is
N052 RefeReNce PReamPlifieR /Quick-Start Guide
0
52 Controller
1
inStallation conSideRationS
inStallation conSideRationS
UNPACKING
When unpacking your N052:
• Save all packing materials in case you need to ship your
0
N
52 in the future.
• Inspect your N
If you discover damage, contact your authorized
Mark Levinson
appropriate claims.
• Locate and remove the accessory box from the shipping
carton. Make sure that all of the items listed below are
included. If any are missing, contact your authorized
Mark Levinson dealer.
2 x IEC power cords (units sold in USA/EU/Korea);
1 IEC power cord (units sold in China)
2 x Multi-pin N
1 x Multi-pin N
0
1 x N
52 remote control (2 x AAA alkaline batteries
installed in the factory)
1 x Phillips screwdriver
1 x Pair white gloves (for use during unpacking and
initial setup)
1 x USB memory stick containing the
0
52 for signs of damage during shipment.
®
dealer for assistance in making
0
52 DC power cables
0
52 control cable
N052 User Guide
PLACEMENT AND VENTILATION
• Install the Controller and the Preamplifier each on its
own shelf to ensure proper ventilation.
• Ensure that you install the Controller and Preamplifier
on solid, flat and level surfaces.
• Install the Preamplifier chassis as close as possible to
associated audio components to keep interconnecting
cables as short as possible.
NOTE: In some cases it is better to use longer
interconnecting cables between the Preamplifier and
power amplifier(s) to allow the use of shorter speaker
wires. Contact your authorized Mark Levinson dealer
for advice.
• Select a dry, well-ventilated location that is out of direct
sunlight.
• Allow at least 1/2 inch to 1 inch (13mm – 25mm) of
clearance above each chassis for proper heat dissipation.
• DO NOT place either chassis on a thick rug or carpet or
cover either chassis with a cloth, as this might prevent
proper cooling.
• DO NOT expose the N
steam, smoke, dampness, or excessive dust. Avoid
installing the N
producing appliances.
0
52 to high temperatures, humidity,
0
52 near radiators and other heat-
1 x Warranty/product registration card
Please register your N
0
52 within 15 days of your purchase.
Register online at www.marklevinson.com or complete the
included product registration card. Retain your original,
dated sales receipt as proof of warranty coverage.
2
N052 RefeReNce PReamPlifieR /Quick-Start Guide
inStallation conSideRationS
POWER REQUIREMENTS
The N052 has been designed for use with 100 – 240-volt,
50Hz/60Hz AC (alternating current), with a maximum current
draw of 65W. It includes a detachable IEC power cable
intended for use in the region where the N
Connection to an AC voltage other than that for which the
0
N
52 is intended can create a safety and fire hazard and
may damage the unit. If you have any questions about the
voltage requirements for your N
0
52 or about the line voltage
in your area, contact your authorized Mark Levinson dealer
before plugging the N
CAUTION: Although your N
0
52 into an AC power outlet.
0
52 will operate from 100V – 240V,
50Hz/60Hz AC, operating it from a voltage that is different
from that where the unit was originally shipped and sold
may require the use of a power cord that is different from
the one supplied with your N
0
52. Contact your authorized
Mark Levinson dealer for additional assistance.
WARNING! MAKE SURE all components in the audio
system are properly grounded. Do not defeat the safety
purpose of polarized or grounding-type plugs with
“ground-lifter” or “cheater” adapters. Doing so may cause
dangerous voltage to build up between components, which
may result in personal injuries and/or product damage.
0
52 is sold.
OPERATING STATES
The N052 has three operating states:
Off: The AC mains power is disconnected using the
Controller’s rear-panel Power switch or by removing the
power cord from the Controller’s rear panel.
Standby: The N
can be selected via the Setup menu: Green, Power Save,
and Normal.
Green:
This mode removes power from almost all of the
0
N
52’s circuits, allowing the unit to be activated only via an
IR control signal, a 5V – 12V trigger or a press of the Standby
button. This mode provides maximum power conservation
and is the factory-default Standby mode.
Power Save:
audio circuits, but keeps the control circuitry powered
and ready to receive commands from either the front
panel controls or the remote control. This mode provides
moderate power conservation.
Normal:
its audio outputs, but keeps all of its control and audio
circuits powered. This mode provides the least amount
of power conservation but allows the N
to remain warmed up to deliver optimal performance at
all times.
0
52 Standby mode has three settings that
This mode removes power from the N052’s
This mode shuts off the N052’s display and mutes
0
52’s audio circuits
enGliSh
On: The entire N
0
52 is powered up and all configured
outputs are active.
0
The N
52 has an Auto Off feature that automatically places
it into the Standby mode after 20 minutes of no user control
input or audio signal passing through the unit. The factorydefault setting for the Auto Off feature is on (engaged). You
can turn the Auto Off feature off (disengaged) in the Setup
menu. See the
You should unplug the N
N052 User Guide
0
52 from the AC wall outlet during
for details.
lightning storms and extended periods of non-use.
CAUTION: BEFORE moving the N
0
52, make sure it is
powered off with the Controller’s rear-panel Power
switch. Then make sure the power cord is disconnected
from the Controller’s rear-panel connector and the AC
power outlet.
N052 RefeReNce PReamPlifieR /Quick-Start Guide
3
GettinG StaRted
GettinG StaRted
FRONT-PANEL OVERVIEW
N052 PREAMPLIFIER
N052 CONTROLLER
Preamplifier
Logo
Preamplifier
LED
Select
Knob
IR
Receiver
Aux Button
and LED
Preamplifier chassis controls/indicators
Preamplifier LED:
illuminates dimly when the N
illuminates fully when the N052 is On,
0
52 is in either the Green or
Power Save Standby mode, and flashes slowly in unison
with the Standby LED when the N
0
52 is in the Normal
Standby mode.
Preamplifier Logo:
0
the N
52 is On, and turns off when the N052 is in Standby
The Mark Levinson logo lights when
or is Off.
4
N052 RefeReNce PReamPlifieR /Quick-Start Guide
Setup Button
and LED
Enter
Button
Display
Intensity
Button
Balance
Button
and LED
Mute Button
and LED
Front-Panel
Volume
Knob
Display
Standby
Button
and LED
NOTE: For complete information about the functions of
the front-panel controls and their settings parameters,
see the
N052 User Guide.