UNIVERSE PLUS STGL & STGM SERIES
GAS TILTING SKILLETS
INSTALLATION - OPERATION - MAINTENANCE
OPEN LEG BASED MODELS
30P-STGL
40P-STGL
44 Lakeside Avenue, Burlington, Vermont 05401 USA
Telephone: (802) 658-6600 Fax: (802) 864-0183
www.mi.com PN 14-0384 Rev B (3/15)
© 2014 - Market Forge Industries Inc.
CLOSED BASED MODELS
30P-STGM
40P-STGM

Your Service Agency’s Address:
Model
Serial number
Skillet installed by
Installation checked by

IMPORTANT
TABLE OF CONTENTS
WARNING: Improper installation, adjustment, alternation,
service or maintenance can
cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly
before installing or servicing
this equipment.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE
USER SMELLS GAS MUST BE
POSTED IN A PROMINENT LOCATION. This information may
be obtained by contacting your
local gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or
other ammable vapors or liquids in the vicinity of this or any
other appliance.
INSTALLATION
Service Connections ..................................................... 2
Installation Instructions ................................................... 3
OPERATION
Operating Instructions .................................................... 5
Cooking Tips ............................................................ 6
Suggested Cooking Temperatures ......................................... 7
MAINTENANCE
Cleaning ................................................................ 9
The information contained in this
manual is important for the proper installation, use, and maintenance of this skillet. Adherence
to these procedures and instructions will result in satisfactory
baking results and long, trouble free service. Please read
this manual carefully and retain
it for future reference.
ERRORS: Descriptive, typographic or pictorial errors are
subject to correction. Specications are subject to change
without notice.

Service Connections
MANIFOLD GAS PRESSURE AND INPUTS
W.C.
Natural Gas 3.5” 93,000 126,000
Propane 10.0” 93,000 126,000
NOTE: HIGH ALTITUDE - If equipment is to be installed
above 2,000 feet specify installation height, so that
proper gas orifices can be provided.
30 Gal.
BTU
40 Gal.
BTU
SERVICE CONNECTIONS
G Gas Connection - Supplied through 3/4” NPT
pipe. A gas shut-off valve must be installed
in supply piping convenient and adjacent to
appliance.
E Electrical Connection - 120V units supplied
with 8’ foot cord with 3 prong plug.
CW Cold Water - 3/8” O.D. NPT to faucet (Optional)
HW Hot Water - 3/8” O.D. NPT to faucet (Optional)
D Drain - 1-1/2” drain NPT (Optional)
10.5
[267]
29.69 [754]
1.68 [43]
HW
CW
CW
HW
27.94 [710]
36 [914] 30 GAL.
46 [1168] 40 GAL.
18 [457] 30 GAL.
23 [584] 40 GAL.
D
27.88 [708] 30 GAL.
37.88 [962] 40 GAL.
*OPTIONAL
E
G
25.75
[654]
DIMENSIONS ARE IN
INCHES [MM]
1.68 [43]
33 [838]
G
E
16.38
26.13 [664]
[416]
37 [940]
31.63 [803]
48.88 [1241]
41.44 [1052]
36 [914]
37.75 [959]
32.63 [829] 30 GAL.
42.63 [1083] 40 GAL.
*OPTIONAL: Pull out sliding
sink drain draw with splash shield for
open leg skillets
REAR FLANGE FOOT DETAIL
2 EQUALLY SPACED Ø 7/16 [11]
HOLDES ON 205 [63] B.C.
9.5 [241]
PAN I.D.
12 [305]
POUR
PATH
6 [152]
12.5 [318]
18.5 [470]
Figure 1
29.75 [756]
6 [152]
G
E
D
8.5 [216]
1.53 [39]
31.63 [803]
26.13 [664]
73.34 [1863]
10 [254] CLEARANCE FROM WALL
InstallatIon
2