Market Forge STHE-12-TGG User Manual

GAS TWO COMPARTMENT
G
MODELS: STHE-12-TGG (12-Pan)
STHE-16-TGG (16-Pan)
SIZE:
STHE-12-TGG 76” High x 24” Wide x 33” Front-to-Back (1953mm High x 610mm Wide x 838mm Front-to-Back)
STHE-16-TGG 70-3/8” High x 36” Wide x 33” Front-to-Back (1788mm High x 914mm Wide x 838mm Front-to-Back)
DESCRIPTION:
Shall be a Market Forge Model, ___________________ convection steamer with an individual gas steam gen-
erator for each cavity. AGA/CGA and NSF Certied. The steamer shall be constructed of a satin nish stainless
steel type 304. The cooking chamber is a one piece all welded type 316 stainless steel with coved corners. The heavy duty door shall have an inner liner of stainless steel with a full perimeter gasket seal, an outer liner of one piece all welded stainless steel, and a positive lock and seal mechanism with spring release. Each compart­ment shall be provided with removable stainless steel pan supports. A stainless steel drip trough shall be inte­grally connected to drain to collect condensate when the doors are opened.
The control housing shall be constructed of stainless steel with a full access removable panel. Each compart­ment shall have individual controls which include an il­luminated three way power switch (ON/OFF/DELIME), a pilot ready light, a pilot cooking light, an ignition light, a 60 minute electric timer which sounds an audible sig­nal at the end of the cooking cycle, solid state generator controls and electronic ignition for each generator. Steam
ow to the cooking chamber shall be cut off when the
door is opened and reactivated when the door is closed.
The STHE-12-TGG shall be mounted on a 24” cabinet base. The STHE-16-TGG shall be mounted on a 36” cabinet base. Cabinet base is constructed of #4 stainless steel with exterior hinged door and 6” (152mm) stainless
steel legs with adjustable anged feet. The cabinet shall
house the two generators, automatic blow-down and drain box.
CONVECTION STEAMER
JOB NAME: ________________________ ITEM NO.: _________________________ NO. REQUIRED: ____________________
STHE-12-TGG Shown
OPERATION SHALL BE BY:
Natural gas. L.P. gas.
Gas red, stainless steel steam generator(s) operating at
0 psi (0 kg/cm2) with controls equipped for operation on 120 V, 1 pH, 60 Hz.
STANDARD FEATURES:
De-lime mode power setting.
Automatic blow-down.
Split water lines.
Thermostatically controlled drain.
Single drain connection.
Electronic ignition.
(4) anged feet.
Redundant controls and generator for each
compartment.
All stainless steel constructed steam generator(s).
Safety relief valve.
Left side access panel.
De-liming ports on front of each compartment.
Load Compensating Timers.
Constant Steam Position.
OPTIONAL ITEMS AT EXTRA COST:
Prison package 120-minute timer Casters KleenSteam Water Filter System
SPEC SHEET: S-6038A
04/12
Two Compartment Steamer
The manufacturer reserves the right to modify materials and specications without notice.
35 Garvey Street • Everett • MA • 02149-4403
Tel: (617) 387-4100 • Toll Free: (866) 698-3188
Fax: (617) 387-4456 (MA and Overseas) • Fax: (800) 227-2659 (Ex. MA)
E-mail: custserv@mi.comwww.mi.com
24” (610)
36” (914) STHE-16-TGG Only
28”
(711)
6” (152)
29.5” (749)
32.13” (816)
41”
(1041)
STHE-12-TGG
76.88” (1953)
STHE-16-TGG
70-375” (1788)
SAFETY RELIEF
VALVES
18” (457)
STHE-16-TGG
DRAIN
3.5” (89) DRAIN
1.25” (32)
1.5” (38)
2.5” (64)
15.75” (400)
1” (25)
33.13” (841)
49.25” (1251)
REAR FLANGED FOOT DETAIL 2 EQUALLY SPACED o7/16” (11mm) HOLES ON 2-1/2” (63mm) B.C.
EC
GW
CW
G
D
CW
GW
EC
LEFT0RIGHT0BACK
6” (152)
CLEARANCE:
SPEC SHEET: S-6038A
04/12
G
GAS TWO COMPARTMENT
CONVECTION STEAMER
DETAILS & DIMENSION
SERVICE CONNECTIONS
Gas Powered
EC Electrical Connection - 120V, 60 Hz, 1 pH with
ground. Unless otherwise specied. Furnished
with a 6 foot cord with 3 prong plug. Max 4.0 AMPS.
G Gas Connection - 3/4” (19mm) IPS Supply line
required.
CW Condensing Cold Water - 3/8” (10mm) OD
Tubing at 25-50 PSI (1.8-3.5 kg/cm2)
GW Generator Water - 3/8” (10mm) OD Tubing at
25-50 PSI (1.8-3.5 kg/cm2)
D Drain - 2” (51mm) IPS pipe to open oor drain.
DO NOT MAKE SOLID CONNECTION TO FLOOR DRAIN. Max Length before open air gap opening: 24” (610mm) NO BENDS OR ELBOWS.
Drain: 1 1/2” O.D. pipe coupled to 1 1/2” O.D. tempering
tank drain. Do not make solid connection to oor drain.
PVC and CPVC pipe are not acceptable materials for drains
MODEL BTU/HR. kW/HR.
STHE-12-TGG 190,000 56
STHE-16-TGG 190,000 56
Two Compartment Steamer
FOOD SERVICE EQUIPMENT
PRINTED IN U. S. A. 35 Garvey Street • Everett • MA • 02149-4403
GAS SUPPLY PRESSURE (W.C.)
NATURAL PROPANE
6” (152mm) - 14” (354mm) 12” (305mm) - 14” (354mm)
It is our policy to build equipment which is design certied by C.S.A. and N.S.F. However, a continuing program of product improvement makes it necessary
to submit new models to the agencies as they are developed and consequently not all models bear the appropriate agency labels at all times.
IMPORTANT: Before connecting water to this unit, have water supply analyzed to make sure that hardness is no greater than 2.0 grains per gallon and a pH level is within the range of 7.0–8.5. Water that fails to meet these stan­dards should be treated by the installation of a water con­ditioner. Equipment failure caused by inadequate water quality is not covered under warranty.
MODEL SHIP WEIGHT
STHE-12-TGG 700 lbs.
STHE-16-TGG 900 lbs.
Tel: (617) 387-4100 • Toll Free: (866) 698-3188
Fax: (617) 387-4456 (MA and Overseas) • Fax: (800) 227-2659 (Ex. MA)
E-mail: custserv@mi.comwww.mi.com
Loading...