Market Forge R-R4 Installation Manual

R SERIES
HEAVY DUTY RANGES
INSTALLATION - OPERATION - MAINTENANCE
24” MODELS
36” MODELS
48” MODELS
60” MODELS
 R-R10  R-RG12-8  R-RG24-6  R-RG36-4  R-RG48-2  R-RG60  R-RRG24-6
44 Lakeside Avenue, Burlington, Vermont 05401 USA
Telephone: (802) 658-6600 Fax: (802) 864-0183
www.mi.com PN 14-0400 Rev A (9/14)
© 2014 - Market Forge Industries Inc.
Your Service Agency’s Address:
Model
Serial number
Oven installed by
Installation checked by
IMPORTANT
TABLE OF CONTENTS
WARNING: Improper installa­tion, adjustment, alternation, service or maintenance can cause property damage, in­jury or death. Read the instal­lation, operation and mainte­nance instructions thoroughly before installing or servicing this equipment.
INSTRUCTIONS TO BE FOL­LOWED IN THE EVENT THE USER SMELLS GAS MUST BE POSTED IN A PROMINENT LO­CATION. This information may be obtained by contacting your local gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors or liq­uids in the vicinity of this or any other appliance.
INSTALLATION
Introduction .............................................................. 2
Location ................................................................. 3
Dimensions and Burner Options ........................................... 4
Utility Connections ....................................................... 5
High Shelf Assembly ..................................................... 7
OPERATION
Operating Instructions .................................................... 8
MAINTENANCE
Cleaning & Periodic Maintenance .......................................... 9
The information contained in this manual is important for the prop­er installation, use, and mainte­nance of this oven. Adherence to these procedures and instruc­tions will result in satisfactory baking results and long, trou­ble free service. Please read this manual carefully and retain it for future reference.
ERRORS: Descriptive, typo­graphic or pictorial errors are subject to correction. Speci­cations are subject to change without notice.
Introduction
IMPORTANT INFORMATION
Safe and satisfactory operation of your equipment de­pends on proper installation. Installation must conform with local codes, or in the absence of local codes, the Na­tional Fuel Gas Code, (ANSI Z-223.1 Latest Edition). In Canada installation should conform to installation codes
for gas burning appliances and equipment standard
(CAN1-B149.1 Natural Gas) or (CAN1-B149.2 Propane Gas).
The installation must conform with local codes, or in the absence of local codes, to the national fuel gas code, ANSI Z223.1 (or latest addenda). The Appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system in excess of 1/2 PSI (3.45Kpa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve dur­ing any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 PSI (3.45Kpa).
The gas supply line must be at least the same size as the gas inlet of the appliance.
Electrical wiring from the Electric Meter, main control box or service outlet to appliance must be electrically ground­ed in accordance with local codes or, in the absence of local codes, the National Electric Code (ANSI/NFPA 70 Current). In Canada wiring should conform with Canadian Electrical Code (CSA-C22.1).
SERVICE
Installation of the equipment should be performed by qualied, certied, licensed and/or authorized personnel
who are familiar with and experienced in state/local instal­lation codes.
Operation of the equipment should be performed by quali­ed and authorized personnel who have read this manual and are familiar with the functions of the equipment.
Service of the equipment should be performed by quali­ed personnel who are knowledgeable with Market Forge cooking equipment.
SHIPPING DAMAGE CLAIM PROCEDURE
The equipment is crafted and inspected carefully by
skilled personnel before leaving the factory. The trans­portation company assumes full responsibility for safe
delivery upon acceptance of this equipment. If shipment
arrives damaged:
Visible loss or damage:
Note the damage or loss on freight bill or express delivery and signed by the person making the delivery.
File claim for damages immediately:
Regardless of the extent of damages.
Concealed loss or damage:
If damage is noticed after unpacking, notify the transpor-
tation company immediately and le a “Concealed Dam­age” claim with them. This should be done within fteen
(15) days from the date delivered. Retain container for inspection.