Market Forge R-1600G Service Manual

R-1600G
ROUND COUNTERTOP GAS TILTING SKILLET
PARTS AND SERVICE MANUAL
EFFECTIVE NOVEMBER 24, 2015
The Company reserves the right to make substitution in the event that items specied are not available.
ERRORS: Descriptive and/or typographic errors are subject to correction.
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 658-6600 Fax: (802) 860-3732
MARKET FORGE INDUSTRIES
www.mi.com
P/N 14-0390 Rev C
TABLE OF CONTENTS
TROUBLESHOOTING ..................................................................3
ILLUSTRATED PART LIST
NEW EXPLODED VIEW ................................................................4
OLD EXPLODED VIEW .................................................................7
NOVEMBER 24, 2015 2 R-1600G COUNTERTOP GAS TILTING SKILLET
TROUBLESHOOTING
BURNER DOES NOT COME ON:
1. Gas supply to unit is “OFF”.
2. Manual shut off valve is “OFF.”
3. Thermostat is not turned “ON.”
4. Pan not in lowest position.
5. Glow coil not functioning.
BURNER PRODUCES CARBON DEPOSITS:
1. Wrong orice size.
2. Increase primary air. Clean air opening.
3. Wrong gas supply.
4. Incorrect pressure at supply.
NOVEMBER 24, 2015 3 R-1600G COUNTERTOP GAS TILTING SKILLET