Market Forge MT10T10G300A User Manual

TWO GAS 10 GALLON
G
MODELS: MT10T10G200A
MT10T10G300A
SIZE: 36” x Wide x 33” Front-to-Back
(914mm Wide x 838mm Front-to-Back) Height without Handle: 47.5” (1200mm) Height with Handle: 58.5” (1500mm)
DESCRIPTION:
Market Forge Model ________ Steam Jacketed Tilting Kettles. Kettles will be mounted on a 28” (711mm) high cabinet base. Hot and cold water  ll faucet, depressed area and drains, and steam control valve will be located on
stainless steel marine-edged counter-top. A 4” (120mm) deep clean-up pan 12” x 10” (305mm x 254mm) with re-
movable splash guard will be standard. Splash guard will be removable so that it may also be attached to a food
receiving pan. Kettle made from #316 stainless steel will A.S.M.E approved and National Board Registered.
TILTING KETTLES
JOB NAME: ________________________ ITEM NO.: _________________________ NO. REQUIRED: ____________________
SPEC SHEET: S-2159A
10/12
Cabinet base, constructed of a stainless steel frame, which houses the gas  red boiler, will be of modular de­sign to match other Market Forged cooking equipment. Base will be equipped with 6” (125mm) stainless steel
marine-edged countertop and hinged doors with magnet-
ic latches. Units will be polished stainless steel.
CAPACITY:
MT10T10G - Two 10 Gallon (38 liters)
OPERATION SHALL BE BY:
Gas  red, 15 PSI (1kg/cm2), A.S.M.E constructed and National Board Registered steam boiler rated at:
200,000 BTU (Standard) 300,000 BTU (Optional at Extra Cost)
Boiler will be equipped for:
Natural Gas LP Gas
Manifold and pilot gas pressure will be 3 1/2” (89mm) for
Natural Gas and 10” (254mm) for LP Gas. Incoming gas pressure must not exceed 14” (357mm) W.C.
Boiler will be automatically  lled with hot water and brought to 15 PSI (1kg/cm2) pressure when heat and
water switches are turned on and automatically drained under pressure when switches are turned off. Automatic cold water condenser will condense exhausted steam
into water before releasing it to drain. Unit also includes safety valve, low water cut-off, water strainer, and des-
caler.
OPTIONAL AT EXTRA COST:
One-piece lift-off stainless steel cover Stainless steel wire basket Clean-up brush Steam Take-Off kit Total Concept Boiler Descaling Chemical
FOOD SERVICE EQUIPMENT
Two 10 Gallon Tilting Kettles
Tel: (617) 387-4100 • Fax: 1-800-227-2659 (Ex. MA) • (617) 387-4456 (MA and Overseas)
E-Mail: CUSTSERV@m i.com • Website: www.m i.com
35 Garvey Street • Everett • MA • 02149
SPEC SHEET: S-2159A
28"
ST
43mm
HW
CW
5"
ST
G1
76mm
3"
400mm
15 3/4"
1 3/4"
D
102mm
4"
152mm
D
G1
G
6"
8"
205mm
EC
ST
471mm
18 1/2"
33"
G
51mm
610mm
(100 or 200K)
445mm
17 1/2"
24"
(300K)
5"
127mm
2"
2 3/4"
70mm
(100 or 200K)
EC
5 1/2"
369mm
838mm
ST
280mm
10 1/2"
36"
64mm
FLUE
914mm
2 1/2"
127mm
CW
HW
58"
1473mm
711mm
22"
559mm
10/12
Two 10 Gallon Tilting Kettles
FOOD SERVICE EQUIPMENT
G
TWO GAS 10 GALLON
TILTING KETTLES
DETAILS & DIMENSIONS
SERVICE CONNECTIONS
Gas Fired
G Gas Connection - 3/4 (19mm) NPT 200,000 BTU
G1 Gas Connection - 1 (25mm) NPT 300,000 BTU
HW
Hot Water - 3/8” (9.5mm) O.D. tubing for hot water to
generator. Hot water lines will have a maximum of 50 PSI (3.5kg/cm2) and a minimum of 25 PSI (1.8kg/
cm2) water pressure.
CW
Cold Water - 3/8” (9.5mm) O.D. tubing for cold water
to condenser. Cold water lines will have a maximum
HWK
of 50 PSI (3.5kg/cm2) and a minimum of 25 PSI (1.8kg/cm
1/2” (13mm) O.D. tubing for hot water to kettle ll
2
) water pressure.
faucet.
CWK
1/2” (13mm) O.D. tubing for cold water to kettle ll faucet.
D
Drain - Pipe full 2” (50mm) I.P.S. to ush oor drain
capable of receiving water owing at a maximum rate
of 5 gallons (19 liters) per minute. DO NOT MAKE SOLID CONNECTION TO FLOOR DRAIN.
EC
Electrical Connection - 115 VAC, 60 Hz, 2 amps, 1/2” (13mm) conduit connection or equivalent. Use wire suitable for at least 90°C.
ST*
Steam Take-Off - Connection for operation of adja­cent steam-powered equipment
* Steam supply connection available on either side of cabinet base.
NOTES: Allow 3” (76mm) space from side wall and 6” (152mm) from rear wall if adjoining wall is combustible.
If unit is to be installed where elevation exceeds 2,000’ (609.6 meters) above sea level, specify installation altitude
so that proper gas orices can be provided.
PVC & CPVC pipe are not acceptable materials for drains.
CAUTION:
Before connecting water to this unit, water supply should be analyzed to make sure hardness is no greater than 2.0
grains per gallon and pH level is within the range of 7.0-
8.5. Water that fails to meet these standards should be treated by installation of water conditioner. EQUIPMENT
FAILURE CAUSED BY INADEQUATE WATER QUAL­ITY IS NOT COVERED UNDER WARRANTY.
It is our policy to build equipment which is design certied by U.L., A.S.M.E., N.S.F. and C.S.A. However, a continuing program of product improvement makes
it necessary to submit new models to the agencies as they are developed and consequently not all models bear the appropriate agency labels at all times.
PRINTED IN U.S.A.
Tel: (617) 387-4100 • Fax: 1-800-227-2659 (Ex. MA) • (617) 387-4456 (MA and Overseas)
E-Mail: CUSTSERV@mi.com • Website: www.mi.com
35 Garvey Street • Everett • MA • 02149