Market Forge MPS-3E Installation Manual

OWNER’S MANUAL
Form Number: S-6112 12/12 Printed in USA 35 Garvey Street, Everett, MA 02149
Telephone (617) 387-4100, (866) 698-3188
Fax (617) 387-4456, (800) 227-2659
custserv@mfii.com, www.mfii.com
ELECTRIC CONVECTION STEAMER
MODEL: MPS-3E
0
IMPORTANT NOTES FOR INSTALLATION AND OPERATION
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment.
This manual should be retained for future reference.
Intended for commercial use only. Not for household use.
Adequate clearances must be maintained for safe and proper operation.
1
TABLE OF CONTENTS
1.0 SERVICE CONNECTIONS ............................ 1
Electrically Operated ..................................... 1
Pan Capacity ................................................. 1
2.0 INSTALLATION INSTRUCTIONS ................. 2
GENERAL ..................................................... 2
UNPACKING ................................................. 2
LOCATION .................................................... 2
LEVELLING................................................... 2
ANCHORING STEAMER .............................. 2
STACKING KIT ............................................. 2
FIGURE 1 / Stand Dimensions ..................... 3
PLUMBING CONNECTIONS........................ 3
ADJUSTMENT FOR HIGH ALTITUDE
LOCATIONS ................................................. 4
ADJUSTMENT FOR DRAIN WATER
TEMPERATURE ........................................... 4
DRAIN CONNECTIONS ............................... 4
FIGURE 2 / Drain Connections ..................... 4
WATER QUALITY ......................................... 5
VENT HOOD ................................................. 5
ELECTRICAL CONNECTIONS .................... 5
TESTING PROCEDURES ............................ 6
3.0 OPERATION INSTRUCTIONS ...................... 7
CONTROLS .................................................. 7
BEFORE FIRST USE ................................... 8
PREHEAT ..................................................... 8
COOK ............................................................ 8
SHUTDOWN ................................................. 8
DRAINING THE BOILER .............................. 8
STEAM COOKING ........................................ 9
PREPARATION ............................................ 9
ACCEPTABLE PAN SIZES ........................... 9
4.0 SUGGESTED COOKING GUIDELINES ......10
COOKING HINTS ........................................10
PREPARATION ...........................................10
FROZEN FOOD ITEMS ..............................10
Cooking Guide .............................................11
5.0 PREVENTIVE MAINTENANCE ...................13
INTRODUCTION .........................................13
CLEANING (DAILY) ....................................13
CLEANING (WEEKLY) ................................14
DELIMING PROCEDURE: ..........................14
REMOVAL OF SCALE DEPOSITS .............14
GENERATOR DELIMING INSTRUCTIONS15
STAINLESS STEEL ....................................16
TO REMOVE HEAT TINT ...........................16
6.0 TROUBLE-SHOOTING ................................17
GENERAL TROUBLESHOOTING GUIDE ..17 ELECTRICAL FAULT ISOLATION GUIDE .21
Timer Motor .................................................21
Door Interlock Switch ...................................22
Indicator Lights ............................................22
Buzzer ..........................................................22
Wiring ...........................................................22
7.0 ADJUSTMENTS ...........................................23
ADJUSTMENT FOR HIGH ALTITUDE
LOCATIONS ................................................23
Door Gasket Replacement ..........................23
Exterior Panel Removal ...............................23
8.0 PARTS ..........................................................24
FIGURE 3 / Exploded View .........................24
9.0 WIRING ....................................................... 30
2
1.0 SERVICE CONNECTIONS
Electrically Operated
Pan Capacity (Half Size Pans)
EC
Electrical Connection - 1-1/8” (29mm) electric connection to controls.
Size – Deep
1”
2-1/2”
4”
6”
GW
Generator Water - 3/8” (10mm) OD tubing at 25-50 PSI.
MPS-3E
6 3 2
1
CW
Cold Water - 3/8” (10mm) OD tubing at 25-50 PSI.
CAUTION:
Before connecting water to this unit, water supply should be analyzed to make sure hardness is no greater than 2.0 grains and pH level is within the range of 7.0-8.5. Water which fails to meet these standards should be treated by installation of water conditioner. EQUIPMENT FAILURE CAUSED BY
INADEQUATE WATER QUALITY IS NOT COVERED UNDER WARRANTY.
D
Drain - 1” (25mm) IPS piped to open floor drain.
NO SOLID CONNECTION TO FLOOR DRAIN. NO BENDS OR ELBOWS.
AMP/PHASE
MODEL
kW
SINGLE PHASE
THREE PHASE
208V
220V
240V
208V
240V
380V
415V
480V
MPS-3E
7.5
36
34
31.3
20.8
18.8
11.4
10.4
9
SERVICE CONNECTIONS
1
2.0 INSTALLATION INSTRUCTIONS
GENERAL
The MPS-E steamers are single compartment electric pressureless steam cookers with an internal electric steam generator that maintains standby water temperature at approximately 205oF. MPS-3E is rated 7.5 kW. MPS-6E is rated 12 kW.
At high altitude locations a lower temperature is required to achieve atmospheric steaming. Contact your authorized service office to have the thermostat adjusted if the steamer will be operated at high altitudes.
UNPACKING
This steamer was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery. Immediately after unpacking the steamer, check for possible damage. If the steamer is found to be damaged after unpacking, save the packaging material and contact the carrier within 15 days of delivery.
Prior to installation, verify that the electrical service agrees with the specifications on the machine data plate which is located on the left side panel.
LOCATION
Allow space for plumbing and electrical connections. Minimum clearances are 0" on the sides and 6" (152mm) on the back for proper air circulation. Allow adequate access for operating and servicing the steamer, 36" (915mm) at the front of the steamer and 15" (381mm) above the steamer.
LEVELLING
Using a spirit level or pan of water in the bottom of the steamer, adjust the leveling feet or the feet on the adjustable legs to level the steamer front-to-back and side-to-side. After the drain is connected, check for level by pouring water onto the floor of the compartment. All water should drain through the opening at the back of the compartment cavity.
ANCHORING STEAMER (Without Legs)
1. Place steamer in the desired location on the leveled counter top and mark four corners. Remove the steamer and drill 5/8" holes as indicated in Figure 1.
2. Apply a bead of RTV or other equivalent sealant around bottom perimeter edge of the steamer. If anchoring the steamer, this bottom seal is necessary to meet NSF requirements.
3. Set steamer on counter and bolt down securely with 1/2 - 13 bolts (not supplied).
STACKING KIT
Follow instructions in the stacking kit when installing stacked convection steamers.
2
2.0 INSTALLATION INSTRUCTIONS (Continued)
WARNING: Disconnect the power supply to the appliance before cleaning or servicing.
WARNING: Plumbing connections must comply with applicable sanitary, safety, and plumbing codes.
FIGURE 1 / Stand Dimensions
Make electrical connection through the 1-1/8" (29mm) diameter hole provided using 3/4" (19mm) trade size conduit. Refer to the wiring diagram located inside the right side panel. Use 90oC minimum insulated wire.
PLUMBING CONNECTIONS
The water supply inlets are provided with 3/8" (10mm) compression fittings for 3/8" O.D. copper tubing. The water supply line pressure should be 25 - 50 PSI (170 - 345 kPa) for each line. The water supply to the generator tank is separate from the water supply to the cooling system where steam is condensed before entering the drain line.
Install line strainers (not provided). A manual shutoff valve for each supply line must be provided convenient to the steamer.
We recommend treated water feeding the boiler inlet supply, and untreated water feeding the cooling system inlet. Hook-ups are labeled on the back of the steamer.
3
2.0 INSTALLATION INSTRUCTIONS (Continued)
CAUTION: In order to avoid any back pressure in the steamer, do not connect solidly to any drain connection.
ADJUSTMENT FOR HIGH ALTITUDE LOCATIONS
The steamer has been factory set so that when it is ON, and during the READY phase, it will maintain water temperature in the steam generator tank at approximately 205oF (96oC) (just below water boiling point). However, for high altitude locations, an authorized service agency must adjust the steamer to achieve this temperature.
ADJUSTMENT FOR DRAIN WATER TEMPERATURE
Cooling solenoid valves have been adjusted to yield drain temperatures of 140oF. This will vary depending on install location water supply temperature and pressure. A qualified service person should adjust the cooling solenoid valves should the drain temperature be other than desired. Refer to section 7.0 Adjustments on page 23 for adjustment instructions.
DRAIN CONNECTIONS (FIGURE 2)
The drain connection (Fig. 2) must be 1" IPS down, preferably with one elbow only, maximum length of 6 feet and piped to an open air gap type drain. Use copper only.
FIGURE 2 / Drain Connections
4
2.0 INSTALLATION INSTRUCTIONS (Continued)
WARNING: Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit.
WATER QUALITY
The water supply connected to this steamer should contain no more than 2.0 grains of hardness per gallon with pH from 6.5 to 8.0. This degree of hardness and pH can easily be obtained with the use of a properly maintained water softener.
Water supplies vary from one location to another. A local water treatment specialist should be consulted before installing any steam generating equipment.
Untreated water contains scale producing minerals which can precipitate onto the surfaces in the boiler. Due to the temperatures in the boiler, the minerals can bake onto the surfaces and components. This can result in early component failure and reduced product life.
Mineral scale on components causes several problems:
1. The surfaces of the heating devices become coated with scale, reducing the heat transfer efficiency. This can produce hot spots on the heating elements and result in premature failure.
2. The water level probes become coated with scale. Scale will bridge across the probe insulator from the metal extension which senses the water level in the boiler. Once this scale becomes wet, the water level control is unable to maintain the proper water level in the boiler. This situation may cause an electric heating element to fail if the element is not adequately covered by water.
Strainers and filters will NOT remove minerals from the water. Refer to REMOVAL OF LIME SCALE DEPOSITS, page 14.
VENT HOOD
Some local codes may require the steamer to be located under an exhaust hood. Information on the construction and installation of ventilating hoods may be obtained from Vapor Removal from Cooking Equipment, NFPA standard No. 96 (latest edition).
ELECTRICAL CONNECTIONS
Electrical grounding must be provided in accordance with local codes or in the absence of local codes, with the National Electrical Code, ANS/NFPA70, or the Canadian Electrical Code, CSA C22-2, as applicable.
Use copper wire suitable for at least 200oF (90oC). The steamer must be grounded. The wiring diagram is located on the right side panel as you face the steamer.
5
2.0 INSTALLATION INSTRUCTIONS (Continued)
CAUTION: Live steam and accumulated hot water in the compartment may be released when the door is opened.
TESTING PROCEDURES
Once the steamer is installed and all mechanical connections have been made, thoroughly test the steamer before operation.
1. Check that proper water, drain and electrical connections have been made.
2. Turn main power switch ON. After approximately 15 minutes, the READY light should come on, indicating that the water temperature is 205 degrees Fahrenheit.
3. When the READY light comes on, set timer to the “5 minute” position. With door open, observe that no steam is entering the compartment and that the COOKING light is OFF.
4. Close compartment door. The COOKING light should now be illuminated and steam should be heard entering the compartment after about 45 seconds.
5. Check drain line to ensure that water from cold water condenser is flowing through the drain line.
6. Open compartment door and observe that steam supply to chamber is cut off. (READY light should again come on as COOKING light goes off.)
7. Close compartment door and let cooking cycle finish. When the timer returns to “0" position, a buzzer will sound signaling the end of the cooking cycle. Buzzer must be manually turned off by setting the timer to its OFF position.
8. To shut down steamer, turn main power switch OFF and leave compartment door slightly open.
6
3.0 OPERATION INSTRUCTIONS
CAUTION: Live steam and accumulated hot water in the compartment may be released when the door is opened.
CAUTION: An obstructed drain can cause personal injury or property damage.
1
READY LIGHT
When lit, indicates steam generator has reached 200 ready for the cooking cycle.
2
COOKING PILOT LIGHT
When lit, indicates that a cooking cycle is in progress.
3
HALF CYCLE TIMER
The Half Cycle button is pre­programmed to run for 1-1/2 minutes (90 seconds).
4
4. FULL CYCLE TIMER
The Full Cycle button is pre­programmed to run for 2-1/2 minutes or (150 seconds).
5
MAIN POWER SWITCH
The steam generator will automatically fill and begin heating to the pre-set READY temperature for standby. Red light on switch will be illuminated
The steam generator will automatically drain. No indicator lights will be on.
Closes the DRAIN VALVE while
“Total Concept” is being poured into
the steam generator during the delime procedure. Amber light will illuminate
CONTROLS
F (93 C) and is
ON
OFF
DELIME
7
3.0 OPERATION INSTRUCTIONS (Continued)
BEFORE FIRST USE
Clean the protective oils from all surfaces of the steamer. Use a non-corrosive, grease
dissolving commercial cleaner, following manufacturer’s directions. Rinse thoroughly and wipe
dry with a soft clean cloth.
PREHEAT
Turn the main power switch ON. When the READY light comes on, set the timer to 1 minute to preheat the compartment. This should be done when the steamer is first used for the day or whenever the chamber is cold. The door should be closed during the preheat cycle. The COOKING light will be lit. When the buzzer sounds, set the timer to the OFF position. The steamer is now ready to cook.
COOK
With compartment preheated and READY light ON, place pans of food into the compartment and close the door.
Set timer to desired cooking time. (The cooking cycle may be interrupted at any time by opening the door. To resume operation, close the door.) Steam will flow into the compartment and the COOKING light will be lit.
At the end of the cooking cycle, the buzzer will sound, the COOKING light will go off and steam supply to the compartment will cease. Turn the timer to the OFF position to silence the buzzer.
SHUTDOWN
Turn main power switch OFF. The boiler will automatically blow down. Leave the compartment door open to allow the inside to dry out. For an extended shutdown, turn the main power switch OFF; turn power and water supply OFF.
DRAINING THE BOILER
Drain the boiler after each day’s use to flush out minerals and minimize scale build-up. The boiler drains automatically for approximately 4 - 6 minutes after the main power switch is turned off.
Each compartment is equipped with a removable drain screen. Frequently check the drain screen for accumulation of food particles. Should food particles accumulate against, or clog the drain screen, remove it, clean it thoroughly and then replace it in its original position
Frequently check that the compartment drain and plumbing is free of all obstructions. Never place food containers, food or food portion bags in the cooking compartment in such a way that the compartment drain becomes obstructed.
8
3.0 OPERATION INSTRUCTIONS (Continued)
Model
Number of Pans Accommodated
Depth of Pan
1"
2.5"
4"
6"
MPS-3E
6 3 2
1
STEAM COOKING
Your steamer efficiently cooks vegetables or other foods for immediate serving. Steam cooking should be carefully time controlled. Keep hot-food-holding-time to a minimum to produce the most appetizing results. Prepare small batches, cook only enough to start serving, then cook additional amounts to meet demand. Separate frozen foods into smaller pieces to allow more efficient cooking.
Use a pan cover for precooked frozen dishes that cannot be cooked in the covered containers in which they are packed if they require more than 15 minutes of cooking time. When a cover is used, approximately one-third additional cooking time is necessary.
Cooking time for frozen foods depends on amount of defrosting required. If time permits, allow frozen foods to partially thaw overnight in a refrigerator. This will reduce their cooking time.
PREPARATION
Prepare vegetables, fruits, meats, seafood and poultry normally by cleaning, separating, cutting, removing stems, etc. Cook root vegetables in a perforated pan unless juices are being saved. Liquids may be collected in a solid 12 inch by 10 inch pan placed under a perforated pan. Perforated pans are used for frankfurters, wieners and similar items when juices do not need to be preserved. Solid pans are good for cooking puddings, rice and hot breakfast cereals. Vegetables and fruits are cooked in solid pans to preserve their own juices. Meats and poultry are cooked in solid pans to preserve their own juices or to retain broth. Canned foods may be heated in their opened cans (cans placed in 12 inch by 10 inch solid pans) or the contents may be poured into solid pans.
ACCEPTABLE PAN SIZES
The steamer accommodates combinations of 12" x 10" pans, solid or perforated.
9
Loading...