MG SERIES
GAS OPERATED BOILERS
INSTALLATION - OPERATION - MAINTENANCE
MODELS
M24G
M36G
44 Lakeside Avenue, Burlington, Vermont 05401 USA
Telephone: (802) 658-6600 Fax: (802)864-0183
www.mi.com PN 14-0307 Rev D (4/16)
© 2016 - Market Forge Industries Inc.
Your Service Agency’s Address:
Model
Serial number
Boiler installed by
Installation checked by
IMPORTANT
TABLE OF CONTENTS
WARNING: Improper installation, adjustment, alternation,
service or maintenance can
cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly
before installing or servicing
this equipment.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE
USER SMELLS GAS MUST BE
POSTED IN A PROMINENT LOCATION. This information may
be obtained by contacting your
local gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or
other ammable vapors or liquids in the vicinity of this or any
other appliance.
INSTALLATION
Introduction .............................................................. 2
Service Connections ..................................................... 4
OPERATION
Control Panel ............................................................ 6
MAINTENANCE
Cleaning the Boiler ....................................................... 7
The information contained in this
manual is important for the proper installation, use, and maintenance of this boiler. Adherence
to these procedures and instructions will result in satisfactory
baking results and long, trouble free service. Please read
this manual carefully and retain
it for future reference.
ERRORS: Descriptive, typographic or pictorial errors are
subject to correction. Specications are subject to change
without notice.
Introduction
TO THE KITCHEN MANAGER:
1. Read this manual carefully and in its entirety. Contact
Market Forge Ind., Inc. for clarication if necessary.
2. Protect your kitchen personnel from scalding and
other serious injury by providing training programs to
acquaint all equipment operators with the correct and
safe methods of operation.
3. Operators must be made aware of the consequences
of misuse. Steam producing equipment, no matter
who the manufacturer, is inherently dangerous when
misused. The possibility of serious scalding always
exists; the careless and/or untrained operator will be
injured.
4. This equipment must be maintained according to the
guidelines in this manual (see “maintenance”). Lack
of maintenance will lead to a potentially hazardous
condition and possible liability. Operators should re-
port any equipment malfunction immediately and
steps must be taken to correct the problem before
further use of the equipment is allowed.
5. Keep this manual for daily reference.
Market Forge, in the interest of both cost and efciency
has designed these steam boilers with the latest automatic controls in order to make it easier for the operator
to use and maintain this equipment. Standard components are utilized on all models unless variances in size
or capacity dictate a divergence from this policy for more
efciency of operation. This parts and service manual is
written and illustrated to cover all steam boiler equipment
that uses gas as a source of fuel other than those which
have been custom designed under special order.
THEORY OF OPERATION FOR GAS BOILER
An explanation of how the control system operates on automatic gas boilers follows:
After the boiler is lled with water to the proper level and
the fuel switch is turned ON, the main gas valve will be
activated allowing gas to ow to the main burners that will
be ignited by the Spark Pilot. When the boiler builds to its
set pressure, the pressure switch opens. This will open
the circuit to the gas valve that will stop the ow of gas
to the main burners. As the pressure in the boiler drops
the pressure control switch will again complete the circuit
and build the boiler back to its set pressure. To stop all
steam generation place the FILL/ON-OFF switch to the
OFF position.
CAUTION
Be sure to read.
• Keep this appliance area free and clear from combustibles.
• Do not obstruct the ow of combustion and ventilation air.
• Keep this manual for future reference.
• This installation must conform with local codes, or in
the absence of local codes, with the National Fuel
Gas code, ANSI Z223.1-Latest Edition. For installation in Canada, this appliance is to be in accordance
with the current CAN/CGA-B149 (.1 or .2) Installation Code for Gas Burning Appliances and Equipment and/or Local Codes.
• This appliance, when installed, must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electric
Code, ANSI/NFPA70-Latest Edition. For installation
in Canada, All electrical connections are to be made
in accordance with CSA C22.1 Canadian Electrical
Code Part 1 and/or Local Codes.
INSTALLATION
• The boiler and its individual shut off valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressure in excess of 1/2 PSI (0.03 kg/cm2).
• The boiler must be isolated from the gas supply
system by closing its individual manual shut off valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2
PSI (0.03 kg/cm2).
• The wiring diagram label is located on the inside of
the Lift-Off Front Panel.
2