Market Forge M24E Installation Manual

ME SERIES
ELECTRICALLY OPERATED BOILERS
INSTALLATION - OPERATION - MAINTENANCE
MODELS
44 Lakeside Avenue, Burlington, Vermont 05401 USA
Telephone: (802) 658-6600 Fax: (802)864-0183
www.mi.com PN 14-0309 Rev E (10/16)
© 2016 - Market Forge Industries Inc.
Your Service Agency’s Address:
Model
Serial number
Boiler installed by
Installation checked by
IMPORTANT
TABLE OF CONTENTS
WARNING: Improper installa­tion, adjustment, alternation, service or maintenance can cause property damage, in­jury or death. Read the instal­lation, operation and mainte­nance instructions thoroughly before installing or servicing this equipment.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors or liq­uids in the vicinity of this or any other appliance.
The information contained in this manual is important for the prop­er installation, use, and mainte­nance of this boiler. Adherence to these procedures and instruc­tions will result in satisfactory baking results and long, trou­ble free service. Please read this manual carefully and retain it for future reference.
INSTALLATION
Introduction .............................................................. 2
Assembly ............................................................... 3
Service Connections ..................................................... 4
OPERATION
Operating Instructions .................................................... 5
MAINTENANCE
Cleaning the Boiler ....................................................... 6
ERRORS: Descriptive, typo­graphic or pictorial errors are subject to correction. Speci­cations are subject to change without notice.
Introduction
To the Kitchen Manager:
1. Read this manual carefully and in its entirety. Contact
Market Forge Ind., Inc. for clarication if necessary.
2. Protect your kitchen personnel from scalding and other serious injury by providing training programs to
acquaint all equipment operators with the correct and
safe methods of operation.
3. Operators must be made aware of the consequences
of misuse. Steam producing equipment, no matter
who the manufacturer, is inherently dangerous when misused. The possibility of serious scalding always exists, the careless and/or untrained operator will be injured.
4. This equipment must be maintained according to the guidelines in this manual (see “maintenance”). Lack of maintenance will lead to a potentially hazardous condition and possible liability. Operators should re-
port any equipment malfunction immediately and
steps must be taken to correct the problem before
further use of the equipment is allowed.
5. Keep this manual for daily reference.
THEORY OF OPERATION FOR ELECTRIC BOILER:
An explanation of how the control system operates on au­tomatic electric boilers follows:
With the boiler lled with water to the proper level and the
heat switch is turned ON, the contactors will pull in and permit the completion of the electric circuit to the heating elements. When the boiler builds to its set pressure, the pressure switch opens. This will open the circuit to the coil in the contactor, which in turn will drop the contacts in the contactor and shut off the electricity. As the pressure in the boiler drops the pressure control switch will again complete the circuit and build the boiler back to its set pressure. To stop all steam generation place the ON/OFF switch to the OFF position.