ME SERIES
ELECTRICALLY OPERATED BOILERS
INSTALLATION - OPERATION - MAINTENANCE
MODELS
M24E
M36E
44 Lakeside Avenue, Burlington, Vermont 05401 USA
Telephone: (802) 658-6600 Fax: (802)864-0183
www.mi.com PN 14-0309 Rev E (10/16)
© 2016 - Market Forge Industries Inc.
Your Service Agency’s Address:
Model
Serial number
Boiler installed by
Installation checked by
IMPORTANT
TABLE OF CONTENTS
WARNING: Improper installation, adjustment, alternation,
service or maintenance can
cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly
before installing or servicing
this equipment.
FOR YOUR SAFETY
Do not store or use gasoline or
other ammable vapors or liquids in the vicinity of this or any
other appliance.
The information contained in this
manual is important for the proper installation, use, and maintenance of this boiler. Adherence
to these procedures and instructions will result in satisfactory
baking results and long, trouble free service. Please read
this manual carefully and retain
it for future reference.
INSTALLATION
Introduction .............................................................. 2
Assembly ............................................................... 3
Service Connections ..................................................... 4
OPERATION
Operating Instructions .................................................... 5
MAINTENANCE
Cleaning the Boiler ....................................................... 6
ERRORS: Descriptive, typographic or pictorial errors are
subject to correction. Specications are subject to change
without notice.
Introduction
To the Kitchen Manager:
1. Read this manual carefully and in its entirety. Contact
Market Forge Ind., Inc. for clarication if necessary.
2. Protect your kitchen personnel from scalding and
other serious injury by providing training programs to
acquaint all equipment operators with the correct and
safe methods of operation.
3. Operators must be made aware of the consequences
of misuse. Steam producing equipment, no matter
who the manufacturer, is inherently dangerous when
misused. The possibility of serious scalding always
exists, the careless and/or untrained operator will be
injured.
4. This equipment must be maintained according to the
guidelines in this manual (see “maintenance”). Lack
of maintenance will lead to a potentially hazardous
condition and possible liability. Operators should re-
port any equipment malfunction immediately and
steps must be taken to correct the problem before
further use of the equipment is allowed.
5. Keep this manual for daily reference.
THEORY OF OPERATION FOR ELECTRIC BOILER:
An explanation of how the control system operates on automatic electric boilers follows:
With the boiler lled with water to the proper level and the
heat switch is turned ON, the contactors will pull in and
permit the completion of the electric circuit to the heating
elements. When the boiler builds to its set pressure, the
pressure switch opens. This will open the circuit to the
coil in the contactor, which in turn will drop the contacts in
the contactor and shut off the electricity. As the pressure
in the boiler drops the pressure control switch will again
complete the circuit and build the boiler back to its set
pressure. To stop all steam generation place the ON/OFF
switch to the OFF position.
INSTALLATION