Market Forge M-10 User Manual

D
DIRECT CONNECTED
10 GALLON STATIONARY STEAM
JACKETED KETTLE
JOB NAME: __________________________ ITEM NO.: ___________________________ NO. REQUIRED: ______________________
Spec No. S-1628 I
07/04
MODEL: M-10
SIZE: 24" 610mm Wide x 33" 838mm Front-to-Back
DESCRIPTION:
Shall be a Market Forge M-10, 10 gallon (38 liter) stainless steel stationary steam jacketed kettle mounted on a cabinet base. Hot and cold water fill faucet and steam control valve shall be mounted on a stainless steel counter-top. Kettle shall be equipped with a 1 1/2" (38mm) sanitary draw-off valve, which shall be enclosed for sanitary purposes. Swing drain for draw-off shall be removable strainer. Kettle shall be equipped with a stainless steel one­piece hinged cover and a removable strainer. ASME code constructed.
Modular cabinet base equipped with 6" (152mm) stainless steel legs, reinforced die-formed stainless steel marine edged counter-top and hinged doors with magnetic latches.
The manufacturer reserves the right to modify materials and specifica ions without notice
OPERATlON SHALL BE BY:
Direct Steam at _______ PSI (3/4 BHP required)
OPTlONAL AT NO EXTRA COST:
Steam pressure relief valve (Not required if kettle connection to gas or electric steam generator)
OPTlONAL AT EXTRA COST:
26" (660mm) kettle draw-off brush. Clean-up brush. Condensate return kit.
FOOD SERVICE EQUIPMENT
Stationary Steam Jacketed Kettle
An Employee Owned Company
35 Garvey Street  Everett  MA  02149
Tel: (617) 387-4100  Fax: 1-800-227-2659 (Ex. MA)  (617) 387-4456 (MA and Overseas)
E-Mail: CUSTSERV@mfii.com  Website: www.mfii.com
D
DIRECT CONNECTED
10 GALLON STATIONARY STEAM
JACKETED KETTLE
Direct Connected
S
HWK
CWK
D
CR
DETAILS & DIMENSION
SERVICE CONNECTIONS
Steam Supply - 3/4" (19mm) IPS 15 PSI (1.0kg/cm
Hot Water - 1/2" (13mm) OD tubing for hot water kettle fill faucet.
Cold Water - 1/2" (13mm) OD tubing for hot water kettle fill faucet.
Drain - Pipe full 2" (51mm) IPS to flush floor drain.
DO NOT MAKE SOLID CONNECTION TO FLOOR DRAIN.
Condensate Return - 1/2" (13mm) IPS connection for condensate return from kettle when specified.
2
) min 30 PSI (2.1kg/cm2) max.
Spec No. S-1628 I
07/04
NOTES:
Pressure reducing valve is required if incoming pressure exceeds 30 PSI (2.1kg/cm
Pressure relief valve must be installed in incoming steam line if not connected to gas or electric steam generator. Supplied on request at no extra cost.
PVC & CPVC pipe are not acceptable materials for drains.
2
).
*It is our policy to build equipment which is design certified by U.L., A.S.M.E., N.S.F. and C.S.A. However, a continuing program of product improvement makes it
Stationary Steam Jacketed Kettle
FOOD SERVICE EQUIPMENT
necessary to submit new models to the agencies as they are developed and consequently not all models bear the appropriate agency labels at all imes.
An Employee Owned Company
Printed in U.S.A.
35 Garvey Street  Everett  MA  02149
Tel: (617) 387-4100  Fax: 1-800-227-2659 (Ex. MA)  (617) 387-4456 (MA and Overseas)
E-Mail: CUSTSERV@mfii.com  Website: www.mfii.com