Market Forge ETP-5G User Manual

ETP-5G ECO-TECH PLUS
G
mODEL: ● ETP-5G DESCriPTiON: The Eco-Tech Plus Atmospheric
Steamer from Market Forge Industries is a stainless steel
atmospheric steamer with an independent close-coupled
atmospheric 42,000
Benets: The Eco-Tech Plus incorporates a water man-
agement system that reduces the amount of water used
to condense generated steam, resulting in substantial savings on energy-related costs.
Industry First!: The ETP-5G is the only Atmospheric
Steamer that comes complete with a self contained water lter system. The built-in system eliminates the hassle of
where to put the lter and also provides a warning indica-
tor when it is time to change the cartridges.
ATmOSPHEriC STEAmEr
BTU gas steam generator.
JOB NAME: ________________________ ITEM NO.: _________________________ NO. REQUIRED: ____________________
SPEC SHEET: S-6502D
11/11
The Energy Star rating may qualify for rebates in your state. Consult your local utility company for details.
Construction: Eco-Tech Plus cooking compartment and cabinet are stainless steel with unitized body construc­tion. The cooking compartment has removable left, right, and rear body panels. The cooking compartment has a positive, fully insulated, slam-action door constructed of T
ype 300 stainless steel. Door gasket is a one-piece,
NSF Approved silicone rubber gasket mounted on the
inside of the door. The compartment is equipped with a door interlock switch that automatically cuts off power to the gas valve when the door is opened.
TECHN
Cooking Compartment: The compartment is provided
with stainless steel pan support racks and a stainless
steel liner. The front edge of the compartment contains a condensate drip trough that drains automatically to the
water management tempering tank.
Controls: The compartment is controlled by an on/off
power switch and 60-minute electromechanical timer. At the end of the cooking time, a continuous signal will sound which can be silenced by returning the timer to the
off position. An exclusive mode selector gives the opera­tor the option of using the cooking cavity as a holding
cabinet.
Operation: The compartment utilizes a powerful close-
coupled to the cooking compartment. The generator is held in the
iCAL SPECiFiCATiONS:
42,000 BTU steam generator that supplies steam
“ready” mode for quick response for heavy-demand situ­ations. The generator chamber is mounted at the rear of the steamer cavity and close-coupled to the steam com-
partment. The ETP-5G comes standard with a pilotless ignition system, automatic water level control, low-water
cutoff, a preheat thermostat (190°F) and high limit. The generator includes an access port for Total Concept de­limer/descaler.
D
imENSiONS AND CAPACiTY:
Internal Dimensions of cooking compartments: 14” Wide x 17.25” High x 21” Front-To-Back. (
355 mm Wide x 438 mm High x 533 mm Front-To-Back)
Allow 6” 152 mm of space on the right side if height of adjoining wall or equipment exceeds 29” 737 mm.
Capacity:
Cooking compartment will accommodate
12” x 20” x 1” deep pans
(9) (5) 12” x 20” x 21/2” deep pans (3) 12” x 20” x 4” deep pans
OPTiONAL:
12” x 20” x 1” perforated stainless steel pans.
12” x 20” x 2 1/2” perforated stainless steel pans.
12” x 20” x 2 1/2” solid stainless steel pans.
12” x 20” x 4” perforated stainless steel pans.
12” x 20” x 4” solid stainless steel pans.
Total Concept Descaler (case of 4 gallons).
Casters with Strain Relief.
Replacement lter kit (set of 2).
Atmospheric Steamer
The manufacturer reserves the right to modify materials and specications without notice.
35 Garvey Street • Everett • MA • 02149-4403
Tel: (617) 387-4100 • Toll Free: (866) 698-3188
Fax: (617) 387-4456 (MA and Overseas) • Fax: (800) 227-2659 (Ex. MA)
E-mail: custserv@mi.comwww.mi.com
ETP-5G ECO-TECH PLUS
G
G Gas Connection - 3/4” (19mm) Male NPT.
CW Cold Water - 3/8” (10mm) NPT, Maximum 50
D Drain - 1 1/2” O.D. tube to open oor drain. EC Electrical Connection - 120 Volts AC, 60 Hz,
Left Side Right Side Rear
Gas Connection: 3/4” NPT male 3 1/2” W.C. natural 10” W.C. propane
NOTES: If the equipment is to be installed where the el- evation exceeds 2,000 ft. (609.6 meters) above sea level,
specify installation altitudes so that the proper gas orices
can be provided. Rated Input: 42,000 BTU per compart­ment.
SPEC SHEET: S-6502D
11/11
All service connections are made at the bottom of the unit,
in the 6” high space between the oor and the bottom of
the cabinet.
ATmOSPHEriC STEAmEr
SErViCE CONNECTiONS
42,000 BTU’s.
PSI, Minimum 25 PSI.
single phase, comes with 6 foot cord. NEMA
5-15. Total Amps: 2
iNSTALLATiON CLEArANCE
3 6 6
DETAILS & DIMENSION
Drain:
1 1/2” O.D. pipe coupled to 1 1/2” O.D. tempering
tank drain. Do not make solid connection to oor drain.
PVC and CPVC pipe are not acceptable materials for
drains. Before connecting water to this unit, have water supply analyzed to make sure that hardness is no greater than
2.0 grains per gallon and a pH level is within the
range of 7.0–8.5. Water that fails to meet these standards
should be treated by the installation of a water condition-
er. Equipment failure caused by inadequate water quality is not covered under warranty.
Atmospheric Steamer
FOOD SErViCE EQUiPmENT
It is our policy to build equipment which is design certied by C.S.A. and N.S.F. However, a continuing program of product improvement makes it
necessary to submit new models to the agencies as they are developed and consequently not all models bear the appropriate agency labels at all times.
PRINTED IN U. S. A. 35 Garvey Street • Everett • MA • 02149-4403
Tel: (617) 387-4100 • Toll Free: (866) 698-3188
Fax: (617) 387-4456 (MA and Overseas) • Fax: (800) 227-2659 (Ex. MA)
E-mail: custserv@mi.comwww.mi.com
Loading...