- 2 - FLOODLIGHT SYM/ASYM
Lamp:
♦ Should the fixture you have purchased have been delivered without lamp, please refer to the
“compatible lamps” box on the spec sheet relevant to the product you are installing to choose a
proper lamp.
♦ During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp
manufacturer’s notes!
♦ Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the
device was not designed for.
♦ For the installation, you need one lineal R7s Halogen lamp.
Procedure:
Step 1: Move the filter frame from the front of fixture.
Step 2: Unscrew the screw on the front panel, and open the front panel.
Step 3: If replacing the lamp, remove the old lamp from the lamp socket.
Step 3: Place the new lineal R7s Halogen lamp into the device.
Step 4: Close the device, replace the filter frame.
♦ Do not operate this device with opened housing cover!
OPERATION:
♦ After you connected the fixture to the mains, you can control the fixture via your lighting controller.
Maintenance:
To ensure maximum performance of the product, a regular maintenance service should be carried
out. Please make sure the product is cold and disconnected from power supply when doing this.
♦ Clean all reflective parts such as reflectors, mirrors and lenses (if fitted), opening the product, if
necessary.
♦ Check the lamp. The protection shields and the lenses (if fitted) and replace any visibly damaged
component.
♦ Clean air ducts and fans (if fitted) in order to allow proper ventilation activity on the product.
♦ Check internal and external wiring and replace any cable which should be damaged by heat or
mechanical agents.
Connection with the mains:
♦ DANGER TO LIFE! The electric connection must only be carried out by a qualified electrician!
♦ In order to connect the product to the mains, you have to install a power-plug.
♦ The occupation of the connection-cables is as follows:
♦ The earth has to be connected!
♦ Connect the product to the mains with the power-plug.
♦ If the product will be directly connected with the local power supply network, a disconnection switch
with a minimum opening of 3 mm at every pole has to be included in the permanent electrical
installation.
♦ In general, lighting effects should not be connected to dimming-packs.
♦ DANGER TO LIFE! Before taking into operation for the first time, the installation has to be
approved by an expert!
Cable Pin International
Brown Live L
Blue Neutral N
Yellow/Green Earth
TECHNICAL SPECIFICATIONS:
Power supply: Max.230V/AC, 50Hz Max.230V/AC, 50Hz
Power consumption,
Max.500W
Max.1000W
Dimensions (L x W x H);
290x290x210mm
360x290x210mm
Weight:
3.85 kg 4.4 kg
Fitting lamp
K1 R7s 230V 500W K4 R7s 230V 1000W
Maximum ambient temperature Ta:
25°C
25°C
Maximum housing temperature TS:
160°C 210°C
Minimum distance:
1.0m 1.0m