1. Before you initially start-up, please make sure that there is no damage caused by transportation. Should there be any, consult your dealer and do not use the device.
2. CAUTION! Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric shock when touching the wires! Keep away from heaters and other heating sources!
3. Do not mount the device on or near combustible sufaces. Do not operate the device without a lens installed.
4. Always hang the device with the color frame retaining clip in the locked position.
5. This device falls under protection-class I, therefore it is essential that the yellow/green conductor gets connected to
earth. The electric connection must be carried out by a qualified employee.
6. Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the power-cord from time to time.
8. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or
his service agent or a similar qualified person in order to avoid a hazard.
9. Shields, lenses or ultraviolet screens shall be changed if they have become visibly damaged to such an extent that their effectiveness is impaired, for example by cracks or deep scratches.
10. Never let the power-cord come into contact with other cables! Handle the power-cord and all connections with the
mains with particular caution!
11. Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power-cord by the plug. Never pull out the plug by tugging the power-cord.
12. During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective.
13. DANGER OF BURNING! Never touch the device during the operation! The housing heats up to the housing temperature TSURFACE.
14. Don't switch the device on and off in short intervals as this would reduce the lamp's life.
15. HEALTH HAZARD! Never look directly into the light source, as sensitive persons may suffer an epileptic shock
(especially meant for epileptics)!
16. Keep away children and amateurs from the device!
17. There are no serviceable parts inside the device. Maintenance and service operations are only to be carried out by
authorized dealers.
IMPORT
ANT SAFETY
INSTRUCTIONS
Spring clip
Colour frame holder
Tabs
Lens rotation ring
Lamp housing
Yoke
Accessories
Color frame 407CF
Wide Flood lens 400-WFL
Very Narrow Spot lens
400-VNSP Narrow Spot lens 400-NSP Medium Flood lens 400-MFL
MULTIPAR 575/2
- 1 -
MULTIPAR 575/2
Lenses for the MULTI PAR come in four versions. The type or beam spread can be identified by the lens texture.
2.Loosen the knurled bolt on the back of the lamp housing and pull the housing straight out from the back of the fixture.
3.Remove the GKV lamp from its box, holding it by the base. Note: To avoid premature lamp failure , do not touch the lamp glass with your fingers. If you touch the lamp during installation, clean it carefully with rubbing alcohol and a clean, lint -free cloth before operation .
4.Line up the flat sides of the lamp base with the brackets on either side of the socket (Figure 2).
5.Push down on the lamp base until the lamp is firmly seated. Make sure that the lamp is fully seated, with the bottom of the lamp heat sink flush to the lamp housing casting. Caution! lmproperly installed lamps cause premature lamp failure and socket problems .
6.To reinstall the lamp housing, center it on the reflector and the bolt hole, then tighten the knurled bolt to secure the lamp housing in place.
WARNING! Let lamp cool before changing .
Always replace the lamp if it becomes damaged or deformed. Verify that the GKV lamp you use is suitable for the voltage at your facility. 115,
120, 230, and 240 volt GKV lamps are available.
Caution! Operating lamps above their rated voltage reduces lamp life and can cause premature lamp failure .
1.Disconnect the unit from power before installing the lamp.
1.Release the retaining clip by pushing it sideways. The retaining clip opens.
2.lnsert the color frame.
3.Press the retaining clip down until it locks. Note: Use only color frames or top hats with 6.7-inch inside diameter.
Cleaning the reflector
1.Remove the lens so you can access the reflector from the front of the fixture. See Removing a lens on page 2
2.Remove dust with a blast of oil free air, or wipe with a clean, soft, lint-free cotton cloth. lf this is sufficient to remove
dust, go to step 5. Otherwise, continue to step 3.
3.Dampen a clean, soft, lint-free cotton cloth with a mild, soapy water solution and gently wipe the reflector.
4.Remove any soapy water residue with a clean, soft, lint-free cotton cloth dampened with water.
5.Reinstall a lens before using the fixture.
The following recommendations are offered when cleaning and inspecting lenses and reflectors: Do not use glass and window cleaners on the reflector. Chemicals in these cleaners will harm the reflective coating. Do not use paper towels or harsh materials to wipe the reflector. These materials can scratch the surface of the reflector.
WARNING! Unplug the fixture before attempting to clean reflector .
Figure 1
Color frame retaining clip
WARNING! Hang the MUL
TI PAR
with the color frame retaining clip in the locked position
.
The color frame holder is equipped with a spring-loaded retaining clip that prevents color
frames and accessories from falling out.
Lens identification
Retaining clip in the locked position
Very narrow spot Clear glass
15º Round beam shape
VNSP
Installing the GKV Iamp
Lamp housing
Figure 2
Wide flood Many facets,sized 6x12mm 30º x51º
Oblong beam shape
Medium flood Fewer facets,sized 6x22mm 21º x34º
Oblong beam shape
Narrow spot Stipple glass 19º Round beam shape
NSP
MFL WFL
Knurled bolt
Lamp brackets