Mark BEAM 201 User Manual

Rev. 13.03.01
BEAM 201
User Manual / Instrucciones de Usuario
STATEMENT
The product is good packing when ship out the factory. All users should strictly abide by the warnings and nstructions stated in this manual, any damage and results due to misuse and the neglect of this operating manual will be excluded from the deal responsibility this manual will not informed in additionally if have technical changes.
DISPLAY PRODUCTION DESCRIPTION
Thank you for choose this B200 products, this model is the moving head light which is the latest development of the smart, efficient products, beautiful shape, smooth R & D, combined with the advanced technology of today's stage lighting products with international advanced electronic control technology and excellent user-friendly industrial design , fully comply with CE standard, accepted international standard DMX512 signal mode. This moving head lights, use ceramic luminescent film reflector as a condenser system, coupled with the high-quality optical lens components, broadband voltage, a clear pattern, sharp and uniform output light efficiency. Intelligent LED display module, the English language selection mode, intuitive operating menu, shortcut. B200, have 16/20 international standard DMX512 channels optional Horizontal scan: 540 ° vertical scanning 270 ° (16bit precision scanning) electronic correction, dot-matrix display, four touch switch LCD + single-Key flying shuttle can spin. The can be inverted 180 °, the color wheel is combined with white and 14 colors. Gobo wheel: 7 patterns + white effect round by eight prism and atomization function. 0-100% mechanical dimmer, support mechanical strobe and variable strobe effect, strobe macro function. The optical system of the lens group electric focusing, the beam angle of 0 to 4 ° with overheating protection function. Moving head lights are widely used in television, disco, dance halls, nightclubs, large-scale performances and other professional venues
1. PRODUCT INTRODUCTION
Size395L)×287W)×495Hmm Net Weight17.5KG
2. SAFETY INFORMATION
Safety warning message This product is only suitable for professional use, and does not apply to security for other purposes. After you got the lights, please check the package whether have any damage caused by transportation. If there is any damage, do not use this fixture, and please contact the dealer or
1.1 BEAM SIZE
BEAM 201 User Manual/Manual de uso Page 1
EN
Ta =40
manufacturer as soon as possible. This product is only suitable for indoor, IP20 protection class. Lamps should be kept dry to avoid Moisture, overheating or dusty environment. Prevent lamps come into contact with water or any other liquid. The use of this product should pay attention to: fire, heat, electric shock, ultraviolet radiation, the lamp to explode or Shedding caused serious or fatal injury. Need to read the instructions before use energized or installing. Follow through the operation of security methods and pay attention to the warning signs on the specification and equipment. If you have any problem for how to safely operate the equipment. Please contact your dealer.
Please don't use the equipment if the temperature above 40º C
The lens should be changed if had damaged or any problems. Don't change the non-original manufacturer lens. Len size:¢1136×60 mm
Please don't move the package by one person only. When Hang the fixture, please must verify that the facilities to be able to withstand the weight of the lamps at least 10 times more. Please make sure the Mounting hardware is strong enough no any damage, and insurance for the safety rope as auxiliary security fixed in other facilities will need to verify before installation. Installing or removing the equipment, to make the pulley below the work location.
Prohibit straight viewpoint with exposed bulbs to avoid UV damage to the eyes; Do not use the equipment without the lens screen and the lid;
2.1 ANTI-HIGH TEMPERATURE
2.2 BURST PREVENTION
2.3 TO PREVENT FALLING WOUNDING
2.4 UA PROTECTION AND THE BULB EXPLOSION
BEAM 201 User Manual/Manual de uso Page 2
EN
3. PACKAGE
ACCESSORY
CONTENT QUANTITY
1
1 HANG FIXTURE 2 SIGNAL CABLE 1
The lens and the light head covers should be timely replaced if any damage to rupture The Fixture should be used with the protection screen together.
The electrical connection must only be carried out with corresponding qualifications; Before installing, make sure you use the power voltage lamps must comply with the identified power, voltage and have an overload or leakage protection;
Each lamp must be properly grounded, installed in accordance with the relevant standards;
Cut off the power when stall or replace the lamp and the fuse; Prohibit the use of a lightning storm or wet environment.
1. Do not short-circuit temperature protection switch or fuse, use the specified type of fuse.
2. The equipment must be installed away from inflammable and explosive materials.
3. The equipment should be projected range of 3 meters away objects and projectiles temperature less than 60 ° C; ---- 3.0m.
4. Fan or ventilation, at least in the range of 0.5 meters can not be an obstacle.
5. Do not place any object on the lens.
6. Handling at least allow the device to cool for 20 minutes.
7. Do not replace the non-original parts.
2.5 PREVENTION OF ELECTRIC SHOCK
2.6 TO PREVENT BURNING OR FIRE
3.1 ATTACHMENT
USER MANUAL
SAFETY ROPE
BEAM 201 User Manual/Manual de uso Page 3
EN
PACAKGE SIZE
FLY-CASE 2 IN 1 985*450*735
1. Before packed, make sure power is off, and wait for at least 20mins for cooling down.
2. Before clean the fixture, make sure X, Y axis protect lock closed.
3. After packed by plastic bag, high-lift the fixture with two handles besides the product. put the product into the fly-case up-side-down.
4. After packed the product, put the accessory into the accessory case, then closed and lock the fly-case.
5. Fly-case only up stacked two layers. Prohibited upside down
In order to protect the light, there is a protect lock; During the transport , the lock will closed keeping the item in safety state.
Note: Before unpacking check the damage is whether due to the transportation or not, if you find any such damage, please do not use this item, and contact with the dealer or manufacturer as soon as possible.
1. Open the fly-case, and discover the inside plastic bag.
2. High-lift the product by two handles beside the bottom base and move it out.
3. Before power on, make sure you have opened the X, Y axis lock!
BEAM 201 can be placed on the stage, or mounted in an arbitrary direction of the truss. Two fast locks system could fix the item easily
1. Before installation must verify the fast lock is keep in good state, and can withstand at least 10 times the weight of product. Verify that the truss can withstand at least 10 times of the total weight of the product and accessory equipments.
2. Fix the hang fixture into the hole, which located on the base of the price. Seize handle of fasteners, clockwise rotate 1/4 turn and lock. Installed other one fastener in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. INSTALL STANDARD
3.2 TRANSPORT PROTECT LOCK
3.3 ABOUT PACK STAGE
3.4 UNPACKING
4.1 INSTALL LOCK
4.2 EQUIPMENT FIXED
BEAM 201 User Manual/Manual de uso Page 4
EN
5. ALTERNATING CURRENT POWER SUPPLY
Input Voltage
Total Power Frequency
110~240V 230W 50/60Hz
Fuse voltage
Electronic current Specification
250V 6A 5×20
in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. Make sure the X,Y protect locks are opened, Verify that within 3 meters there is no combustibles .
WARNING
Fixture must use two fixing devices, and make sure the fixing device have locked! And only fully clockwise rotate 90 ° can lock the hang fixture! Do remember plus a safety rope, and do not connect the safety rope to plastic handle. It should be connect to the hole on the base!
Attention! One product only can accept one input one output. BEAM 201 DMX cable include 3 contact pins: Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin 3 connected to the positive polarity signal.
DMX512 cable must use the professional shielded twisted pair cable; standard loudspeaker cable is not reliable to control the long-range data.
Attention! Do not overload the connection. One continuous connection can only connect up to 32 devices.
If use the DMX512 splitter. At first connect DMX512 Splitter input terminal to controller. And then connected from the splitter output terminal to next device. Do as above guide to connect other device, and finally coupled with terminal insertion
4.3 FIXTURE CONNECT
5.1 VOLTAGE, POWER, FUSE SPECIFICATION
BEAM 201 User Manual/Manual de uso Page 5
EN
The equipment must be operated by professionals; Make sure that the voltage of power supply must be comply with the voltage identified on the lamp, and must have an overload or leakage electrical protection.
ATTENTION!
Factory has equipped the standard 3 pin plug socket. Connect the power supply as below table. If lamp cable is damaged, replacement should be operate by factory or qualified staff. Any question, please contact professionals or talk to a qualified electrician.
Live wire(L) Null(N) Ground wire
RED BLUE Yellow +Green
6. LAMP
LAMP MODEL POWER OF LAMP LIFE/HOUR COLOR TEMPERATURE
Philips UHP 189 W 2200 HOURS 8000K YODN 5R 200 W 2200 HOURS 8000K YODN 7R 230W 2200 HOURS 8000K
WARNING! There is a safety hazard or damage if install similar bulb To reduce the risk of damage to light ,do change the lamp before using time over 125% of lamp life .
Attention! When replace the lamp is forbidden to touch lamp with bare hand, to avoid the greasy dirt stains filament. filament must be kept clean
1. Disconnect the power. Before replace lamp, fixture need 20 minutes for lamp cooling. Fasten the head with Y axis protect lock in 60 ° position.
2. Use cross screwdriver to open the light body cover, remove the fan bracket, pull out the bulb cable
3. Open stainless steel tablet holder with one hand and the use other hand to pull out the bulb at oblique 15 °
4. Install the lamp
6.2 LAMP REPLACE
6.1 LAMP DESCRIPTION
5.2 POWER PROTECT
BEAM 201 User Manual/Manual de uso Page 6
EN
7. CONTROL PANEL
A001
Rpan: X axis reverse
ON X axis reverse on
OFF X axis reverse off
Rtil: Y axis reverse
ON Y axis reverse on
OFF Y axis reverse off
POWER SIGNAL LIGHT
DMX SIGNAL LIGHT
DISPLAY SCREEN
BUTTON
DMX address: 001
Press E button to enter the DMX address set. Click "up" and "down" button to adjust 0-255 address. Press "E" saved.
Click "up" button to enter this model, "E" button confirm. Click "up" & "down" button to adjust state. Press "E" for confirm
Click "up" button to enter this model, "E" button confirm. Click "up" & "down" button to adjust state. Press "E" for confirm
7.1 CONTROL PANEL INTRODUCTION
8.1. DMX ADDRESS AND X, Y AXIS CONTROL
8. BEAM 201 CONTROL
BEAM 201 User Manual/Manual de uso Page 7
EN
Loading...
+ 16 hidden pages