Mark BEAM 190 User Manual

v. 14.02.01
User Manual / Instrucciones de Usuario
BEAM 190
Item ............................................................................................................................................. 2
1.Product introduce ................................................................................................................ 3
1.1 Fixture Size ........................................................................................................................4
2.Safety information ......................................................................................................... …..5
2.1 Anti-high temperature .................................................................................................... ...6
2.2 Burst Prevention .................................................................................................................6
.
2.3 To prevent falling wounding ...............................................................................................6
2.4 UV protection and the bulb explosion ..............................................................................6
2.5 Prevention of electric shock ................................................................................................ 6
2.6 to prevent burning or fire ......................................................................................................6
3.Packing and shipping .............................................................................................................7
3.1 packaging randomized accessories project .............................................................................7
3.2 transport the protection locks. ................................................................................................ 7
3.3 device packaging ................................................................................................................. ...7
3.4 Unpacking. ............................................................................................................................. 7
4.Installation standards ................................................................................................. …...8
4.1 device fixed to the bracket ......................................................................................................8
4.2 rigging installation ................................................................................................................. 8
4.3 connected devices .................................................................................................................. 8
5.AC power........................................................................................................................... ……9
5.1 Fuse......................................................................................................................................8
5.2 Power connection ................................................................................................................8
6.Lamp......................................... ....................................................................................………10
6.1Bulb Description ....................................................................................................................10
6.2 changing a light bulb .......................................................................................................... ..10
7.Channels................................................................................................................. ..........……12
8. Clear and Maintenance…………................................……...........................…..………..15
9. PCB Board….......................………................................……...........................…..………..16
BEAM 190 User Manual/Manual de uso Pag 2
EN
STATEMENT
The product is good packing when ship out the factory. All users should strictly
abide by the warnings and instructions stated in this manual, any damage and results due to misuse and the neglect of this operating manual will be excluded from the deal responsibility this manual will not informed in additionally if have technical changes.
PRODUCT DESCRIPTION
Thank you for choose this BEAM 190 products, this model is the moving head light which is the latest development of the smart, efficient products, beautiful shape, smooth R & D, combined with the advanced technology of today's stage
lighting products with international advanced electronic
control technology and excellent user
-
friendly industrial design , fully comply with CE standard,
accepted international standard DMX512 signal mode.
This moving head lights, use ceramic luminescent
film reflector as a condenser system, coupled with the high-quality optical lens components, broadband voltage, a clear pattern, sharp and uniform output light efficiency. Intelligent LED display module, the English language selection mode, intuitive oper
ating menu,
shortcut.
This Beam spot
, have 16/
20 international standard DMX512 channels optional Horizontal scan:
540 ° vertical scanning 270 ° (16bit precision scanning) electronic correction,
LCD display, can be
inverted 180 °, the color wheel is combined with white and 1
4
colors. Gobo wheel:
17
patterns +
white effect round by 8 facet prism and atomization function. 0
-
100% mechanical dimmer, support mechanical strobe and variable strobe effect, strobe macro function. The optical system of the lens group electric focusing, the beam angle of 0 to 4° with overheating protection function.
This Moving head lights are widely used in television, disco, dance halls, nightclubs, performances and other professional venues
BEAM 190 User Manual/Manual de uso Pag 3
EN
1. PRODUCT INTRODUCE
1.1 FIXTURE DIMENSIONS
Size::302×346×502mm
Gross Weight:18.2KG
Net weight:15KG
BEAM 190 User Manual/Manual de uso Pag 4
EN
2. SAFETY INFORMATION
Safety warning: This product is only suitable for professional use, and does not apply to security for other purposes. After you got the lights, please check the package whether have an
y damage caused by
transportation. If there is any damage, do not use this fixture, and please contact the dealer or manufacturer as soon as possible. This product is only suitable for indoor, IP20 protection class. Lamps should be kept dry to avoid Moisture, overheating or dusty environment. Prevent lamps come into contact with water or any other liquid. The use of this product should pay attention to: fire, heat, electric shock, ultraviolet radiation, the lamp to explode or Shedding caused serious or fata
l injury. Need to read the instructions before use energized or installing. Follow through the operation of security methods and pay attention to the warning signs on the specification and equipment. If you have any problem for how to safely operate the
equipment.
Please contact your dealer.
BEAM 190 User Manual/Manual de uso Pag 5
EN
2.1 ANTI -HIGH TEMPERATURE
ta =40°C
Please don’t use the equipment if the temperature above 40
2.2 BURST PREVENTION
The lens should be changed if had damaged or any problems. Don’t change the non-original manufacturer lens. Len size: 119mm×23mm
2.3 TO PREVENT FALLING WOUNDING
Please don’t move the package by one person only. When Hang the fixture, please must verify that the facilities to be able to withstand the weight of the lamps at least 10 times more. Please make sure the Mounting hardware is strong enough no any damage, and insurance for the safety rope as auxiliary security fixed in other facilities will need to verify before installation. Installing or removing the equipmen
t, to make the pulley
below the work location
2.4 UV PROTECTION AND THE BULB EXPLOSION
Prohibit straight viewpoint with exposed bulbs to avoid UV damage to the eyes; Do not use the equipment without the lens screen and the lid; The lens and the light head covers should be timely replaced if any damage to rupture The Fixture should be used with the protection screen together.
2.5 PREVENTION OF ELECTIC SHOCK
The electrical connection must only be carried out with corresponding qualifications; Before inst
alling, make sure you use the power voltage lamps must comply with the identified power, voltage and have an overload or leakage protection; Each lamp must be properly grounded, installed in accordance with the relevant standards; Cut off the power when stall or replace the lamp and the fuse; Prohibit the use of a lightning storm or wet environment.
2.6 TO PREVENT BURNING OR FIRE
1,The fixture can be
mounted directly on the surface of ordinary combustible material.
2. Do not short
-
circuit temperature
protection switch or fuse, use the specified type of fuse
.
3. The equipment must be installed away from inflammable and explosive materials.
4. The equipment should be projected range of 3 meters away objects and projectiles temperature
less than 60 ° C; .
BEAM 190 User Manual/Manual de uso Pag 6
EN
5. Fan or ventilation, at least in the range of 0.5 meters can not be an obstacle.
6. Do not place any object on the lens.
7. Handling at least allow the device to cool for 20 minutes.
8. Do not replace the non
-
original parts.
3. PACKAGE
3.1 ATTACHMEN T
BEAM 190
packed with fly
-case of one in one ,two in one ,or carton box.
Attach follow accessory.
ACCESSORY
CONTENT QUANTITY USER MANUL 1 piece HANG FIXTURE 2 pcs SIGNAL CABLE 1 piece
PACAKGE SIZE
CARTON BOX
37×42×56cm
FLY-CASE 1 IN 1
44×47×72cm
FLY-CASE 2 IN 1
82×47×72cm
3.2 TRANSPORT PROTECT LOCK
In order to protect the light, there is a protect lock; During the transport , the lock will closed keeping the item in safety state.
3.3 ABOUT PACK STAGE
1. Before packe
d, make sure power is off, and wait for at least 20mins for cooling down.
2. Before clean the fixture, make sure X, Y axis protect lock closed.
3. After packed by
plastic
bag, highlift the fixture with two handles besides the product. put
the product int
o the fly-case up-side-down.
4. After packed the product, put the accessory into the accessory case, then closed and lock the fly-case.
5. Fly-case only up stacked two layers. Prohibited upside down
6. When packed with carton box, equipment should be put
into the foam first, then set into a
carton, pay attention to the vertical position.
3.4 UNPACKING
Note: Before unpacking check the damage is whether due to the transportation or not, if you find any such damage, please do not use this
item, and cont
act with the dealer or manufacturer
as
soon as possible.
1. Open the flycase, and discover the inside plastic bag.
2. High-lift the product by two handles beside the bottom base and move it out.
BEAM 190 User Manual/Manual de uso Pag 7
EN
3. Before power on, make sure you have opened the X, Y axis
lock!
4、INSTALL STRANDARD
4.1 INSTALL LOCK
BEAM 190 can be placed on the stage, or mounted in an arbitrary direction of the
truss. Two fast
locks system could fix the item easily .
4.2 EQUIPMENT FIXED
1. Before installation must verify the fast lock is keep in good state, and can withstand at least 10 times the weight
of product. Verify that the building can withstand at least
10
times of the total weight of the
product and
accessory equipment
s.
2. Fix the hang fixture into the hole, which located on the base of the price. Seize handle
of fasteners, clockwise rotat
e 1/4 turn and lock. Installed other one fastener
in the same method.
3. Using the safety cable
which can withstand 10 times the weight of the equipment.
4. Make sure the X,Y prote
ct locks are opened,
Verify that within 3 meters there is no
combustibles .
WARNING
Fixture must use two fixing devices, and make sure the fixing device have locked!
And only
fully clockwise rotat
e 90 ° can lock the hang fixture!
Do remember plus a safet
y rope, and
do not connect the safety
rope to plastic handle. It should be connect to the hole on the base!
4.3 FIXTURE CONNECT
Attention! One product only can accept one input one output.
BEAM 190 DMX cable include 3 contact pins:
Pin 1, FOR GROUND
; Pin 2 connected to the negative polarity signal
; The pin 3
connected to the positive polarity signal.
DMX512 cable must use the professional
shielded twisted pair
cable
; standard
loudspeaker cable is not
reliable
to control the long
-range data. 24AWG ca
ble is
suitable for more than 300 meters long-distance signal
t
ransmission
and
must add
\ DMX 512 signal amplifier. Do not use two outputs to separate the connection, if separa
te a continuous connection
to branch, DMX512 splitter is necessary.
If use the DMX512 splitter. At first connect
DMX512 Splitter input terminal
to
controller .And then connected
from the splitter output
terminal to next device.
BEAM 190 User Manual/Manual de uso Pag 8
EN
Do as above guide to connect other device,
and finally coupled with terminal insertion
as following:
5、 ALTERNATING CURRENT POWER SUPPLY
5.1 VOLTAGE, POWER, FUSE SPECIFICATION
Input Voltage
Total Power Frequency
110~240V 350W 50/60Hz
Fuse voltage
Electronic current Specification
250V 6A 5×20
5.2 POWER PROTECT
The equipment must be operated by professionals;
Make sure that
the voltage of
power supply must be comply with the voltage identified
on the lamp, and
must
have
an overload or leakage
e
lectrical protection.
ATTENTION!
Factory has equip
ped the standard 3 pin plug socket.
Connect the power supply as below table. If lamp cable
is damaged, replacement should be operate by factory or
qualified staff.
Any question, please contact professionals
or talk to a qualified electrician.
Live wire(L) Null(N) Ground wire
RED BLUE Yellow +Green
BEAM 190 User Manual/Manual de uso Pag 9
EN
6、LAMP
6.1 LAMP DESCRIPTION
LAMP MODEL
POWER OF LAMP
LIFE/HOUR
COLOR TEMPERATURE
PHILIPS MSD
132W
6000 HOURS
9300K
OSRAM HRI
132W
6000 HOURS
9300K
YODN MSD
132W
6000 HOURS
9300K
WARNING! There is a safety hazard or damage
if install similar bulb To reduce the risk
of damage to light
,do change the lamp before using time over 90% of lamp
life .
6.2 LAMP REPLACE
Attention! When replace the lamp
is forbidden
to touch lamp with bare hand, to
avoid the greasy dirt stains filament
. filament must be kept clean
1. Disconnect the power. Before replace lamp, fixture need
20 minutes
for lamp
cooling. Fasten the head with Y axis protect lock in
60 ° positio
n.
2, Use cross
screwdriver to
open
the light body cover, remove the fan bracket,
pull out the bulb cable
as this picture show: