GAS INFRARED HEATERS
MARK EIRE bv
Coolea Macroom
Co. CORK - IRELAND
Phone : +353 (0)26 453 34
Fax : +353 (0)26 453 83
1
USER INSTRUCTIONS
N° 05000221/4
1.
PRODUCT SPECIFICATION
2. SAFETY RECOMMENDATIONS
3. IGNITION
4. SHUT-OFF
5. MAINTENANCE
6. CHANGING THE GAS USED

GAS INFRARED HEATERS
2
1. PRODUCT SPECIFICATION :
Refer to the heater rating plate on the gas supply cover panel (see example
below).
MODEL
MARK
Certificate Number
1312
AP 230
Class NOx 4
Weight
(kg)
2,5 2,9 3,1 3,4 4,1 5,0 5,0 5,5 5,5 6,7 6,7 12,2
Net calorific value
Qn (kW) Hi
2,50 3,30 3,80 5,10 6,75 7,60 7,60 10,20 10,20 13,50 13,50 27,00
G20 consumption
(Natural gas) (m
3
/h)
0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.860
0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 2.110
2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 27.80
2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 25.20
Required air
renewal rate (m3/h)
25 33 38 51 67.5 76 76 102 102 135 135 270

GAS INFRARED HEATERS
3
2. SAFETY RECOMMENDATIONS :
THESE HEATERS MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED INSTALLER
IN ACCORDANCE WITH THE CURRENTLY APPLICABLE SAFETY REGULATIONS AND
WITH THE INSTALLER INSTRUCTIONS.
TO AVOID ABNORMAL MECHANICAL CONSTRAINTS ON THE RADIANT, IT IS
RECOMMENDED THAT IT BE CONNECTED TO THE GAS MAINS BY A FLEXIBLE TUBE.
TO BE INSTALLED IN WELL-VENTILATED PREMISES. NOT FOR DOMESTIC USE.
2.1 HEATER INCLINATION
2.2 MINIMUM SAFETY CLEARANCES (INFLAMMABLE MATERIALS:
max
=70°C)
(*) For an minimum inclination of 20°
GAS SUPPLY
5 to 35°
5 to 35°
WRONG INCLINATION
CORRECT INCLINATION
1m

GAS INFRARED HEATERS
4
3. START-UP :
Manual operation
Open the main gas valve.
Switch the power on.
Start the heater ignition cycle.
If the flame is not lit after 45 seconds, start a second ignition cycle.
If the flame is still not lit or goes out, close the main gas valve, switch
the power off and call your installer.
Automatic control
(MT100, MT150, MTH100 or MTH150 control module)
Open the main gas valve.
Switch the power on.
Check the settings (temperature, time).
Change module programming if necessary.
4. SHUT OFF :
Close the main gas valve.
Switch the power off.
5. MAINTENANCE :
To be performed once a year by your installer, according to the
INSTALLER INSTRUCTIONS.
6. CHANGING THE GAS USED :
For any change in the type of gas used, please contact your installer.

GAS INFRARED HEATERS
MARK EIRE bv
Coolea Macroom
Co. CORK - IRELAND
Phone : +353 (0)26 453 34
Fax : +353 (0)26 453 83
Installer’s Stamp :
1312
USER GUIDE
N° 05000221/4
(TO BE DISPLAYED NEXT TO THE CONTROL UNIT)
M A N U A L O P E R A T I O N
IGNITION :
Open the main gas valve.
Switch the power on.
Start the heater ignition cycle.
If the flame is not lit after 45 seconds, start a second ignition cycle.
If the flame is still not lit or goes out, close the main gas valve, switch
the power off and call your installer.
SHUT-OFF :
Close the main gas valve.
Switch the power off.
MAINTENANCE:
To be performed once a year by your installer, according to the
INSTALLER INSTRUCTIONS.
.

GAS INFRARED HEATERS
MARK EIRE bv
Coolea Macroom
Co. CORK - IRELAND
Phone : +353 (0)26 453 34
Fax : +353 (0)26 453 83
Installer’s Stamp :
1312
USER GUIDE
No. 05000221/4
(TO BE DISPLAYED NEXT TO THE CONTROL UNIT)
A U T O M A T I C C O N T R O L
MT100, MT150, MTH100 or MTH150 modules
IGNITION :
Open the main gas valve.
Switch the power on.
Check the settings (temperature, time).
Change module programming if necessary.
SHUT-OFF :
Close the main gas valve.
Switch the power off.
MAINTENANCE :
To be performed once a year by your installer, according to the
INSTALLER INSTRUCTIONS.