GAS INFRARED HEATERS
MARK EIRE bv
Coolea Macroom
Co. CORK - IRELAND
Phone : +353 (0)26 453 34
Fax : +353 (0)26 453 83
1
USER INSTRUCTIONS
N° 05000221/4
1.
PRODUCT SPECIFICATION
2. SAFETY RECOMMENDATIONS
3. IGNITION
4. SHUT-OFF
5. MAINTENANCE
6. CHANGING THE GAS USED

GAS INFRARED HEATERS
2
1. PRODUCT SPECIFICATION :
Refer to the heater rating plate on the gas supply cover panel (see example
below).
MODEL
MARK
Certificate Number
1312
AP 230
Class NOx 4
Weight
(kg)
2,5 2,9 3,1 3,4 4,1 5,0 5,0 5,5 5,5 6,7 6,7 12,2
Net calorific value
Qn (kW) Hi
2,50 3,30 3,80 5,10 6,75 7,60 7,60 10,20 10,20 13,50 13,50 27,00
G20 consumption
(Natural gas) (m
3
/h)
0.265 0.350 0.400 0.540 0.715 0.805 0.805 1.080 1.080 1.430 1.430 2.860
0.195 0.260 0.300 0.400 0.530 0.595 0.595 0.800 0.800 1.055 1.055 2.110
2.60 3.40 3.90 5.30 7.00 7.90 7.90 10.50 10.50 13.90 13.90 27.80
2.30 3.10 3.60 4.80 6.30 7.10 7.10 9.60 9.60 12.60 12.60 25.20
Required air
renewal rate (m3/h)
25 33 38 51 67.5 76 76 102 102 135 135 270

GAS INFRARED HEATERS
3
2. SAFETY RECOMMENDATIONS :
THESE HEATERS MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED INSTALLER
IN ACCORDANCE WITH THE CURRENTLY APPLICABLE SAFETY REGULATIONS AND
WITH THE INSTALLER INSTRUCTIONS.
TO AVOID ABNORMAL MECHANICAL CONSTRAINTS ON THE RADIANT, IT IS
RECOMMENDED THAT IT BE CONNECTED TO THE GAS MAINS BY A FLEXIBLE TUBE.
TO BE INSTALLED IN WELL-VENTILATED PREMISES. NOT FOR DOMESTIC USE.
2.1 HEATER INCLINATION
2.2 MINIMUM SAFETY CLEARANCES (INFLAMMABLE MATERIALS:
max
=70°C)
(*) For an minimum inclination of 20°
GAS SUPPLY
5 to 35°
5 to 35°
WRONG INCLINATION
CORRECT INCLINATION
1m