USER’S MANUAL 700, 1000, 1500 WATT INVERTER ENGLISH
PRODUCT DESCRIPTION AND APPLICATION
The Marinco inverters convert a DC voltage to a pure AC
sine wave voltage.
SAFETY INSTRUCTIONS
WARNING!
Before using the Inverter, read and save the
safety instructions
Use the Inverter following the instructions and
specifications stated in this manual.
Connections and safety features must be executed
according to the locally applicable regulations
Operation of the Inverter without proper grounding
may lead to hazardous situations!
Use DC-cables with an appropriate size. Integrate a
fuse in the positive wiring and place it nearby the
battery. Refer to the specifications.
If the positive and negative wires on the DC-input
(battery) are exchanged, the Inverter will be damaged.
Damage of this kind is not covered by guarantee.
Check whether all connections are connected
correctly before placing the fuse.
Do not connect the AC-output of the inverter to an
incoming AC source.
Never connect the Inverter in parallel with any other
inverter.
Never open the housing as high voltages may be
present inside!
UNPACKING
The delivery consists of the following parts:
The inverter
This user’s manual
Four ring terminals
After unpacking, check the Inverter for possible damage.
Do not use the Inverter if it is damaged. If in doubt,
contact your supplier.
NEUTRAL GROUNDING
For safe installation,
The chassis ground terminal (see Figure 2, ref. 7)
must be connected to the central grounding point of
the vehicle/ ship
The neutral conductor (N) of the AC output of the
Inverter must be connected to the safety ground
(PE/GND) and a ground fault circuit-interrupter (GFCI)
must be integrated in the wiring of the AC output. See
below for model specific information.
Refer to locally applicable regulations on these issues!
120V models
With the 120V models the neutral conductor of the AC
output circuit of the Inverter is internally connected to the
safety ground during inverter operation automatically and
a ground fault circuit-interrupter (GFCI) is already
integrated in the AC output circuit of the Inverter.
230V models
With the 230V models there is no connection made inside
the inverter between either the line or neutral conductor
to the safety ground.
DIP SWITCH SETTINGS
See Figure 1, ref. 6. Under normal circumstances there is
no need to change the default settings of the DIP
switches: the inverter is immediately ready for use.
To save energy from the battery in no load operation, DIP
switches S1, S2 and S3 can be used to adjust the Power
Saving Mode. The Power Saving Mode scans the output
and when it detects a load which is higher than the
selected threshold value, the inverter is switched on
automatically.
Power Saving Mode S1 S2 S3
Model 700 1000/1500
DISABLE DISABLE 0 0 0
15W 20W 1 0 0
25W 40W 0 1 0
40W 55W 1 1 0
50W 75W 0 0 1
65W 95W 1 0 1
75W 115W 0 1 1
85W 135W 1 1 1
DIP switch S4 is used to select the output frequency
Output frequency S4
50Hz 0
60Hz 1
Figure 1: Front side
2
3
4
5
6
1
LED indicators
AC output
Main switch
DIP switches
R
AC output
120V models:
AC output
230V models: