Maretron SIM100 User Manual

®®
Switch Indicator Module
User’s Manual
Revision 1.0
Copyright © 2008 Maretron, LLP All Rights Reserved
Maretron, LLP
9014 N. 23rd Ave #10
Phoenix, AZ 85021-7850
http://www.maretron.com
Maretron Manual Part #: M001801
Revision 1.0 Page i
SIM100 User's Manual
Revision History
Revision Description
1.0 Original document
Page ii Revision 1.0
®®
Table of Contents
1Introduction ........................................................................................................................... 1
1.1Firmware Revision .................................................................................................... 1
1.2SIM100 Features ...................................................................................................... 1
1.3Quick Install .............................................................................................................. 2
2Installation ............................................................................................................................. 2
2.1Unpacking the Box ................................................................................................... 2
2.2Choosing a Mounting Location ................................................................................. 2
2.3Mounting the SIM100 ............................................................................................... 3
2.4Connecting the SIM100 ............................................................................................ 3
2.4.1NMEA 2000® Connection............................................................................... 3
2.4.2Switch Connections ....................................................................................... 4
2.4.2.1Switch With End of Line Resistor ..................................................... 5
2.4.2.2Switch Without End of Line Resistor ................................................ 5
2.4.3Checking Connections ................................................................................... 6
2.5Configuring the SIM100 ............................................................................................ 6
2.5.1Device Instance ............................................................................................. 6
2.5.2Channel #1 Mode .......................................................................................... 6
2.5.3Channel #2 Mode .......................................................................................... 6
2.5.4Channel #3 Mode .......................................................................................... 6
2.5.5Channel #4 Mode .......................................................................................... 6
2.5.6Channel #5 Mode .......................................................................................... 6
2.5.7Channel #6 Mode .......................................................................................... 6
2.5.8Advanced Configuration… ............................................................................. 7
2.5.9NMEA 2000® PGN Enable/Disable ................................................................ 7
2.5.10Restore Factory Defaults ............................................................................... 7
3Maintenance .......................................................................................................................... 7
4Troubleshooting .................................................................................................................... 7
5Technical Specifications ........................................................................................................ 9
6Technical Support ............................................................................................................... 10
7Installation Template ........................................................................................................... 11
8Maretron (2 Year) Limited Warranty .................................................................................... 12
Table of Figures
Figure 1 – Mounting the SIM100 ............................................................................................... 3
Figure 2 – NMEA 2000® Connector Face Views ....................................................................... 4
Figure 3 – Switch With End of Line Resistor Connection Diagram ............................................ 5
Figure 4 – Switch Without End of Line Resistor Connection Diagram ....................................... 5
Figure 6 – Mounting Surface Template ................................................................................... 11
Table of Appendices
Appendix A – NMEA 2000
Revision 1.0 Page iii
®
Interfacing .................................................................................... A1
®®

1 Introduction

Congratulations on your purchase of the Maretron Switch Indicator Module. Maretron has designed and built your SIM100 to the highest standards for years of dependable and accurate service.
Maretron’s Switch Indicator Module monitors switch closure devices including, but not limited to, safety equipment (e.g., heat, smoke, carbon monoxide, explosive vapor detectors), security systems (e.g., motion, vibration, glass break, door and port hole magnetic switches), and vessel monitoring equipment (e.g., valve closed/open, high water bilge). The SIM100 continually monitors these switch closure devices and broadcasts information over the NMEA 2000 network about the switch state so the crew can be alerted to potential conditions or problems that warrant further investigation. Advanced features of the SIM100 include the ability to detect whether or not power has been disconnected from the monitored device or if the signal wires have been disconnected due to either corrosion, tampering, or for any other reason (if the monitored device is so equipped). With the SIM100, you can rest assured that critical sensors are receiving power, signal wires are connected, and all the safety, security and vessel functions are under constant supervision.
The Maretron SIM100 is designed to operate within the harsh demands of the marine environment. However, no piece of marine electronic equipment can function properly unless installed, configured, and maintained in the correct manner. Please read carefully and follow these instructions for installation, configuration, and usage of the Maretron SIM100 in order to ensure optimal performance.

1.1 Firmware Revision

This manual corresponds to SIM100 firmware revision 1.0.0.

1.2 SIM100 Features

The Maretron SIM100 has the following features.
NMEA 2000® Interface
Waterproof Connectors
Sealed Waterproof Enclosure
Opto-Isolated from NMEA 2000
Monitors and reports switch status
Can detect and report problems like opens and shorts in switch circuits
Compatible with Maretron-Supplied
o Heat Detectors o Smoke Detectors o Carbon Monoxide Detectors o Bilge Water Detectors
Also Compatible With
o Magnetic Switches o Glass Break Detectors o Door, Hatch, and Porthole Magnetic Switches
®
Eliminating Potential Ground Loops
Revision 1.0 Page 1
SIM100 User's Manual

1.3 SIM100 Accessories

Maretron offers the following accessories for the SIM100:
SH-499CSTE Smoke/Heat Detector
CO1000-S-W Carbon Monoxide (CO) Detector (Surface Mount White)
LP1000-S-W Liquid Petroleum (LP) Detector (Surface Mount White)
BHW100 Bilge High Water Detector
MD-6157-N Motion Detector
MS-1035 Magnetic Switch Rectangular (Indoor)
MS-1085-N Magnetic Switch Rectangular (Outdoor)
MS-1055-N Magnetic Switch Cylinder (Indoor/Outdoor)
MS-1075 Magnetic Switch Recessed (Indoor/Outdoor)

1.4 Quick Install

Installing the Maretron SIM100 involves the following five steps. Please refer to the individual sections for additional details.
1. Unpack the box (Section 2.1)
2. Choose a mounting location (Section 2.2)
3. Mount the SIM100 (Section 2.3)
4. Connect the SIM100 (Section 0)
5. Configure the SIM100 (Section 2.5)

2 Installation

2.1 Unpacking the Box

When unpacking the box containing the Maretron SIM100, you should find the following items:
1 – SIM100 – Switch Indicator Module 1 – Parts Bag containing 4 Stainless Steel Mounting Screws 1 – SIM100 User’s Manual 1 – Warranty Registration Card
If any of these items are missing or damaged, please contact Maretron.

2.2 Choosing a Mounting Location

Please consider the following when choosing a mounting location.
1. The SIM100 is waterproof, so it can be mounted in a damp or dry location.
2. The orientation is not important, so the SIM100 can be mounted on a horizontal deck, vertical bulkhead, or upside down if desired.
3. The SIM100 is temperature-rated to 55°C (130°F), so it should be mounted away from engines or engine rooms where the operating temperature exceeds the specified limit.
Page 2 Revision 1.0