RIM100
Run Indicator Module
User’s Manual
Revision 1.0
Copyright © 2008 Maretron, LLP All Rights Reserved
Maretron, LLP
9014 N. 23rd Ave #10
Phoenix, AZ 85021-7850
http://www.maretron.com
Maretron Manual Part #: M002001
Revision 1.0 Page i
Table of Contents
1 Introduction ........................................................................................................................... 1
1.1 Firmware Revision .................................................................................................... 1
1.2 RIM100 Features ...................................................................................................... 1
1.3 Quick Install .............................................................................................................. 1
2 Installation ............................................................................................................................. 2
2.1 Unpacking the Box ................................................................................................... 2
2.2 Choosing a Mounting Location ................................................................................. 2
2.3 Mounting the RIM100 ............................................................................................... 3
2.4 Connecting the RIM100 ............................................................................................ 3
2.4.1 NMEA 2000® Connection............................................................................... 3
2.4.2 Monitored Load Connections ......................................................................... 4
2.4.2.1 AC Load ........................................................................................... 5
2.4.2.2 DC Load ........................................................................................... 5
2.4.3 Checking Connections ................................................................................... 6
2.5 Configuring the RIM100 ............................................................................................ 6
2.5.1 Device Instance ............................................................................................. 6
2.5.2 Channel #1 - #6 Mode ................................................................................... 7
2.5.3 Channel #1 - #6 Label ................................................................................... 7
2.5.4 Advanced Configuration… ............................................................................. 7
2.5.5 NMEA 2000® PGN Enable/Disable ................................................................ 7
2.5.6 Restore Factory Defaults ............................................................................... 7
2.5.7 Installation Description… ............................................................................... 7
3 Maintenance .......................................................................................................................... 7
4 Troubleshooting .................................................................................................................... 8
5 Technical Specifications ........................................................................................................ 9
6 Technical Support ............................................................................................................... 10
7 Installation Template ........................................................................................................... 11
8 Maretron (2 Year) Limited Warranty .................................................................................... 12
Table of Figures
Figure 1 – Mounting the RIM100 ............................................................................................... 3
Figure 2 – NMEA 2000® Connector Face Views ....................................................................... 4
Figure 3 – AC Load Connection Diagram .................................................................................. 5
Figure 4 – DC Load Connection Diagram .................................................................................. 6
Figure 5 – Mounting Surface Template ................................................................................... 11
Table of Appendices
Appendix A – NMEA 2000
Revision 1.0 Page iii
®
Interfacing .................................................................................... A1
1 Introduction
Congratulations on your purchase of the Maretron Run Indicator Module (RIM100). Maretron
has designed and built your RIM100 to the highest standards for years of dependable and
accurate service.
Maretron’s RIM100 monitors both AC and DC electrical circuits and reports, over an NMEA
2000® network, whether or not the electrical circuit is energized and running. The RIM100
works equally as well for monitoring manually switched loads (e.g., running lights, anchor
lights, or deck lights) as it does for automatically switched loads. Monitoring automatically
switched loads (e.g., bilge pumps, engine exhaust/intake fans, and transfer pumps) via the
RIM100 is especially useful because you know exactly when equipment is, or isn't running.
The Maretron RIM100 is designed to operate within the harsh demands of the marine
environment. However, no piece of marine electronic equipment can function properly unless
installed, configured, and maintained in the correct manner. Please read carefully and follow
these instructions for installation, configuration, and usage of the Maretron RIM100 in order to
ensure optimal performance.
1.1 Firmware Revision
This manual corresponds to RIM100 firmware revision 1.0.2.
1.2 RIM100 Features
The Maretron RIM100 has the following features.
• NMEA 2000® Interface
• Waterproof Connectors
• Sealed Waterproof Enclosure
• Opto-Isolated from NMEA 2000® Eliminating Potential Ground Loops
• Monitors and reports the running status of connected devices
• Works with both AC and DC loads
• Works with both automatically and manually switched loads
• Can indicate the status of a wide variety of loads
o Bilge Pumps
o Winches
o Running Lights
o Transfer Pumps
o Exhaust/Intake Fans
1.3 Quick Install
Installing the Maretron RIM100 involves the following five steps. Please refer to the individual
sections for additional details.
1. Unpack the box (Section 2.1)
2. Choose a mounting location (Section 2.2)
Revision 1.0 Page 1
RIM100 User's Manual
3. Mount the RIM100 (Section 2.3)
4. Connect the RIM100 (Section 2.4)
5. Configure the RIM100 (Section 2.5)
2 Installation
2.1 Unpacking the Box
When unpacking the box containing the Maretron RIM100, you should find the following items:
1 – RIM100 – Run Indicator Module
1 – Parts Bag containing 4 Stainless Steel Mounting Screws
1 – RIM100 User’s Manual
1 – Warranty Registration Card
If any of these items are missing or damaged, please contact Maretron.
2.2 Choosing a Mounting Location
Please consider the following when choosing a mounting location.
1. The RIM100 is waterproof, so it can be mounted in a damp or dry location.
2. The orientation is not important, so the RIM100 can be mounted on a horizontal deck,
vertical bulkhead, or upside down if desired.
3. The RIM100 is temperature-rated to 55°C (130°F), so it should be mounted away from
engines or engine rooms where the operating temperature exceeds the specified limit.
Page 2 Revision 1.0