Marathon Special Products 699 GP XX PSB Data Sheet

Product Data Sheet

699 GP XX PSB
Replace “XX” with 01 through 23 for number of poles
Terminal Block– Open Back 20 Amps, 150 Volts (AC/DC)
Insulator Strip Required for Voltage Rating Copper Wire Only
Wire Range with Wire Binding Screw: #14 - #16 AWG 7/16” Centers
(6 Pole shown)
Application torque: 9 in. lbs
Electrical Ratings:
20A with Listed ring lug or unprepared wire, (Based on NEC Table 310-16, 75°C columns)
150 Volts AC/DC (UL 1059 Class B, User Group – Commercial Appliances)
Short Circuit Current Rating: 10,000A (Default)
Approved for Factory Wiring.
Mechanical Ratings:
Maximum insulator base temperature: 150°C (302°F)* UL RTI
Flammability rating of insulator base: UL 94V-1
* Use outside these ratings needs to be judged in the end-use application.
Materials:
Connector (Eyelet): Brass, tin plated.
Insulator base: Phenolic
Screw, #6-32 Binder head, Phil-Slot: Brass, nickel plated
Agency Approvals:
UL Recognized, UL 1059 Terminal Block Standard, File No. XCFR2.47811
CSA Certified, CSA C22.2 No. 158, File No. LR19766
CE compliant, IEC 60947-7-1
RoHS Compliant
Wire Range:
Copper Wire Stranding Classes - Number of Strands
Wire Size Torque Solid Class B Class C
14 9 in. Lbs 1 7 19 16 9 in. Lbs 1 7 19
Suggested product mounting hardware: #6 fastener, torque to 10-15 in. lbs.
ACCESSORIES:
Insulator Strip

Accessory options may affect ratings – consult factory

Loading...
+ 1 hidden pages