![](/html/95/958b/958bdb77603eebd4963970b327cde15928deff560fb9d6f2e4ca2a3a42fc95f5/bg1.png)
Product Data Sheet
3XX Series Modified
Replace “XX” with 01 through 24 for number of poles
Terminal Block– Closed Back
Modified Construction
30 Amps, 600 Volts (AC/DC)
(Variety of hardware shown)
Copper Wire Only
Wire Range with Wire Binding Screw: #10 - #14 AWG
9/16” Centers
Electrical Ratings:
• 30A with unprepared wire, (Based on NEC Table 310-16, 75°C columns)
• 30A with Listed ring lug, (Based on NEC Table 310-16, 75°C columns)
• 600 Volts AC/DC (UL 1059 Class C, User Group – General Industrial)
• Short Circuit Current Rating: 10,000A (Default)
• Approved for Factory Wiring.
NOTE: Use outside these ratings must be judged in end-use application
Mechanical Ratings:
• Insulator base temperature rating: -40° C/F to 150°C (302°F)* UL RTI
• Flammability rating of insulator base: UL 94V-0
Materials:
• Connector (Contact): Brass, tin plated.
• Insulator base: Phenolic
• Drive screw (Rivet): Stainless steel
• Screw, #8-32 Binder head, Phil-Slot: Steel, nickel plated
Agency Approvals:
• UL Recognized, UL 1059 Terminal Block Standard, File No. XCFR2.E62806
• CSA Certified, CSA C22.2 No. 158, File No. LR19766
• CE compliant, IEC 60947-7-1
• RoHS Compliant
![](/html/95/958b/958bdb77603eebd4963970b327cde15928deff560fb9d6f2e4ca2a3a42fc95f5/bg2.png)
Wire Range:
Copper Wire Stranding Classes - Number of Conductors
Wire Size Torque Solid Class B Class C
Tab width: 0.250
Tab thickness: 0.032
Mounting:
Suggested product mounting hardware: #8 fastener, torque to 15-20 in. lbs.
Accessories:
• Line to Line Jumper (LL300)
• Quick Connects or Fastons
• Half Quick Connects or Half Fastons
• Solder Terminal (S)
• Half Solder Terminal (HS)
• Feed Thru Solder (L)
• Feed Thru Solder (LSL)
• Sems Pressure Saddle Screw (SP)
• Sems Pressure Saddle Screw with External Lock Washer (SPSE)
• Phil-Slot Brass Screw (PSB)