CERTIFICATION DATA SHEET
Model#: 145TTFN16045 AA WINDING#: ZT4166 R1 3
CONN. DIAGRAM: A-EE7308 ASSEMBLY: F1/F2 CAPABLE
OUTLINE: A-104719-750
TYPICAL MOTOR PERFORMANCE DATA
HP KW SYNC. RPM F.L. RPM FRAME ENCLOSURE KVA CODE DESIGN
2&2 1.49&1.49 1800 1755&1450 145T TEFC N B
PH Hz VOLTS FL AMPS START TYPE DUTY INSL S.F AMB°C ELEVATION
3 60/50 230/460#190/
380
6/3&6.8/3.4 LINE OR
INVERTER
CONTINUOUSF3 1.15/1.15 40 3300
FULL LOAD EFF:
86.5&85.5
3/4 LOAD EFF: 85.5 1/2 LOAD EFF: 82.5 GTD. EFF ELEC. TYPE NO LOAD AMPS
FULL LOAD PF: 72&78 3/4 LOAD PF: 63 1/2 LOAD PF: 50 84 SQ CAGE INV RATED 3.8 / 1.9
F.L. TORQUE LOCKED ROTOR AMPS L.R. TORQUE B.D. TORQUE F.L. RISE°C
6 LB-FT 60 / 30 24.5 LB-FT 408 32.5 LB-FT 542 35
SOUND PRESSURE
@ 3 FT.
SOUND POWER ROTOR WK^2 MAX. WK^2 SAFE STALL TIME STARTS
/HOUR
APPROX. MOTOR
WGT
62 dBA 72 dBA 0.13 LB-FT^2 0 LB-FT^2 20 SEC. 2 69 LBS.
*** SUPPLEMENTAL INFORMATION ***
DE BRACKET
TYPE
ODE BRACKET
TYPE
MOUNT
TYPE
ORIENTATION SEVERE
DUTY
HAZARDOUS
LOCATION
DRIP
COVER
SCREENS PAINT
STANDARD STANDARD RIGID HORIZONTAL FALSE NONE FALSE NONE BLUE
(POWDER)
BEARINGS GREASE SHAFT TYPE SPECIAL DE SPECIAL ODE SHAFT
MATERIAL
FRAME
MATERIAL
DE OPE
BALL BALL POLYREX EM T NONE NONE 1144
STRESSPROOF
(C-223)
CAST IRON
6205 6203
THERMO-PROTECTORS THERMISTORS CONTROL SPACE /n HEATERS
THERMOSTATS PROTECTORS WDG RTDs BRG RTDs
NONE NOT NONE NONE NONE FALSE NONE VOLTS
If Inverter equals NONE, contact factory for further
information
*
N
O
T
E
S
*
INVERTER TORQUE: CONSTANT 20:1
INV. HP SPEED RANGE: NONE
ENCODER: NONE
NONE NONE
NONE NONE PPR
BRAKE: PROVISIONS FOR KIT NONE
NONE P/N NONE
NONE NONE
NONE FT-LB NONE V NONE Hz
DATE: 06/23/2017 06:58:36 AM
FORM 3531 REV.3 02/07/99
** Subject to change without notice.
Uncontrolled Copy