CERTIFICATION DATA SHEET
Model#: 56C17D2100 M WINDING#: CE48456 NONE 3
CONN. DIAGRAM: A-EE9002M ASSEMBLY: F1 ONLY
OUTLINE: A-SS79799-625
TYPICAL MOTOR PERFORMANCE DATA
HP KW SYNC. RPM F.L. RPM FRAME ENCLOSURE KVA CODE DESIGN
1/3 0.25 1800 1725 56 DP J NO DESIGN
CODE
PH Hz VOLTS FL AMPS START TYPE DUTY INSL S.F AMB°C ELEVATION
1 60 115/208-230 5.8/3.1-2.9 ACROSS THE
LINE
CONTINUOUSB3 1.25 40 3300
FULL LOAD EFF: 64 3/4 LOAD EFF: 61.4 1/2 LOAD EFF: 54.7 GTD. EFF ELEC. TYPE NO LOAD AMPS
FULL LOAD PF: 60 3/4 LOAD PF: 54.5 1/2 LOAD PF: 43.9 0 CAP START IND RUN 4.2 / 2.1
F.L. TORQUE LOCKED ROTOR AMPS L.R. TORQUE B.D. TORQUE F.L. RISE°C
16 LB-FT 21.4 / 10.7 28.9 LB-FT 181 38 LB-FT 238 30
SOUND PRESSURE
@ 3 FT.
SOUND POWER ROTOR WK^2 MAX. WK^2 SAFE STALL TIME STARTS
/HOUR
APPROX. MOTOR
WGT
- dBA - dBA - LB-FT^2 - LB-FT^2 - SEC. - - LBS.
*** SUPPLEMENTAL INFORMATION ***
DE BRACKET
TYPE
ODE BRACKET
TYPE
MOUNT
TYPE
ORIENTATION SEVERE
DUTY
HAZARDOUS
LOCATION
DRIP
COVER
SCREENS PAINT
STANDARD STANDARD RESILIENT
BASE-
EXTENDED
STUDS
HORIZONTAL FALSE NONE FALSE NONE GRAY
(POWDER)
BEARINGS GREASE SHAFT TYPE SPECIAL DE SPECIAL ODE SHAFT
MATERIAL
FRAME
MATERIAL
DE OPE
BALL BALL MULTEMP SRL T NONE NONE 1144
STRESSPROOF
(C-223)
ROLLED STEEL
6203 6203
THERMO-PROTECTORS THERMISTORS CONTROL SPACE /n HEATERS
THERMOSTATS PROTECTORS WDG RTDs BRG RTDs
NONE AUTOMATIC NONE NONE NONE FALSE NONE VOLTS
If Inverter equals NONE, contact factory for further
information
*
N
O
T
E
S
*
INVERTER TORQUE: NONE
INV. HP SPEED RANGE: NONE
ENCODER: NONE
NONE NONE
NONE NONE PPR
BRAKE: NONE NONE
NONE P/N NONE
NONE NONE
NONE FT-LB NONE V NONE Hz
DATE: 06/27/2017 06:40:21 AM
FORM 3531 REV.3 02/07/99
Uncontrolled Copy