Date: 27-Sep-2004 |
Model: SR4500 |
|
|
|
|
|
|
|
SERVICE |
BULLETIN |
Page: |
1 / 1 |
REF.NBR: MZ04-065 |
|
|
|
|
|||
Subject: |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
Level |
|
Application: |
The reading accuracy improvement of the |
||
|
|
|
|||
|
|
|
|||
|
|
See below |
continuation code of the Remote Controller. |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Int.ref: |
|
|
|
|
|
|
|
|
[PHENOMENON] |
|
|
|
|
|
A reading leak occurs in the continuation code of the Remote Controller. (It is especially UP / DOWN of the Volume.)
[REASONS]
The protection circuit operates by Impulse Noise.
[SOLUTION]
1.POS.NO R564 RESISTOR (47K OHM) is changed to RESISTOR 15K OHM +-5% 1/6W (Part no. 00MGD05153160 ) on the VIDEO PCB.
R564
[NECESSARY PART]
POS.NO R564 00MGD05153160 (15K OHM +-5% 1/6W)
This is “nsp” part, MARANTZ will not supply this part.
[REMARKS]
1. This problem apply to the following serial number.
SR4500/N1S |
MZ000426000001 to MZ000426000520 |
SR4500/N1G |
MZ000426000001 to MZ000426000628 |
2.This improvement has been done in the production serial number MZ000430xxxxxx and after.
3.The following model has improved from the top of mass production. SR4500/A1B/A1S, SR4500/N1B, SR4500/U1B/U1S, SR4500/K1G and SR4500/L1G.
Approved by S.NAGAO Written by
WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19)