Marantz SR-4500-2 Sevice Bulletin

SERVICE BULLETIN
See below
Date: 27-Sep-2004 Model: SR4500
Page: 1 / 1 REF.NBR: MZ04-065
Subject:
The reading accuracy improvement of the
continuation code of the Remote Controller.
[PHENOMENON]
A reading leak occurs in the continuation code of the Remote Controller. (It is especially UP / DOWN of the Volume.)
[REASONS]
The protection circuit operates by Impulse Noise.
[SOLUTION]
1. POS.NO R564 RESISTOR (47K OHM) is changed to RESISTOR 15K OHM +-5% 1/6W (Part no.
00MGD05153160 ) on the VIDEO PCB.
[NECESSARY PART]
POS.NO R564 00MGD05153160 This is “nsp” part, MARANTZ will not supply this part.
[REMARKS]
1. This problem apply to the following serial number.
SR4500/N1S MZ000426000001 to MZ000426000520 SR4500/N1G MZ000426000001 to MZ000426000628
2. This improvement has been done in the production serial number MZ000430xxxxxx and after.
3. The following model has improved from the top of mass production. SR4500/A1B/A1S, SR4500/N1B, SR4500/U1B/U1S, SR4500/K1G and SR4500/L1G.
(15K OHM +-5% 1/6W)
Int.ref:
R564
Approved by S.NAGAO Written by
WQ-19 2 817
/additional rule 3 (1st Issue 2003-03-19)
Loading...