SERVICE BULLETIN
Circulation: Application:
xfor information customer complaint in case of service
mandatory |
See Below |
|
................... |
||
|
Date: 15-May.-2003 |
Model: SR110 |
|
|
|
|
Page: |
1 / 1 |
REF.NBR: MZ02-038 |
|
|
|
Subject:
The problem that the character of the FL indication changes
Int.ref:
[PHENOMENON]
The character of the FL indication changes when the power is turned on.
[SOLUTION]
Replace C317(0.1uF/50V) to 100pF/50V on the Front Circuit Board
[NECESSARY PART]
POS.NO. C317 DD95103300 (CER.CHIP)
[REMARKS]
The countermeasure apply to this claim only.
This solution has already been applied in the production after the serial numbers below.
SR110/N1S : MZ000119000131 and after
SR110/U1S : MZ000119000013 and after
Approved by S.NAGAO Written by
WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19)