Marantz SR-110 Sevice Bulletin

0 (0)
Marantz SR-110 Sevice Bulletin

SERVICE BULLETIN

Circulation: Application:

xfor information customer complaint in case of service

mandatory

See Below

...................

 

Date: 15-May.-2003

Model: SR110

 

 

 

Page:

1 / 1

REF.NBR: MZ02-038

 

 

 

Subject:

The problem that the character of the FL indication changes

Int.ref:

[PHENOMENON]

The character of the FL indication changes when the power is turned on.

[SOLUTION]

Replace C317(0.1uF/50V) to 100pF/50V on the Front Circuit Board

[NECESSARY PART]

POS.NO. C317 DD95103300 (CER.CHIP)

[REMARKS]

The countermeasure apply to this claim only.

This solution has already been applied in the production after the serial numbers below.

SR110/N1S : MZ000119000131 and after

SR110/U1S : MZ000119000013 and after

Approved by S.NAGAO Written by

WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19)