Date: 15-May.-2003 Model: SR110
Page: 1 / 1 REF.NBR: MZ02-038
SERVICE BULLETIN
Circulation: Application:
Subject:
The problem that the character of the FL indication
changes
x for information customer
complaint in case of service
mandatory
...................
See Below
Int.ref:
[PHENOMENON]
The character of the FL indication changes when the power is turned on.
[SOLUTION]
Replace
C317
(0.1uF/50V) to
100pF/50V
on the
Front Circuit Board
[NECESSARY PART]
POS.NO.
C317 DD95103300 (CER.CHIP)
[REMARKS]
The countermeasure apply to this claim only.
This solution has already been applied in the production after the serial numbers below.
SR110/N1S : MZ000119000131 and after
SR110/U1S : MZ000119000013 and after
Approved by S.NAGAO Written by
WQ-19 2 817