LVDT/A & LVDT/D Manual
Contents 
Chapter 1 The LVDT Conditioner ..................................................................................................... 1 
Chapter 2 Installing the LVDT/A & LVDT/D ......................................................................................... 2 
Terminal Connection ..................................................................................................................... 3 
Dimensions of the Enclosure and Mounting Holes ................................................................................... 3 
Output Connections ...................................................................................................................... 4 
Output Current Mode Settings – Jumpers JP1 & JP2 ................................................................................ 5 
Chapter 4 Input Calibration ........................................................................................................... 6 
Span (gain) - SW1 (0 = OFF  1 = ON) .................................................................................................. 6 
Zero (offset) - SW2 ....................................................................................................................... 7 
Excitation Amplitude - SW2/8 .......................................................................................................... 7 
The LVDT/A & LVDT/D Filter ........................................................................................................... 7 
Filter Cut off - SW3 (0 = OFF  1 = ON) ............................................................................................... 7 
Chapter 5 Specification for LVDT/A & LVDT/D .................................................................................... 8 
W A R R A N T Y .......................................................................................................................... 10 
Chapter 1 The LVDT Conditioner 
The LVDT provides a wide range of signal conditioning for LVDT transducers. 
Offered in two versions, the LVDT/A for 110/240 V AC or 18-24 V DC operation and the LVDT/D which is DC powered 
only. 
Transducer sensitivities between 20 mV and 10 V are accommodated by a combination of DIL switch settings and a 
fine trim potentiometer. 
Similar arrangements are provided for any ‘zero’ errors in the transducers and can be used to offset the readings by 
up to ±35% of full scale. 
A wide frequency response is offered, of typically DC to 200 Hz. There is an on-board low pass filter, which can be 
switched in to reduce high frequency fluctuations or induced electrical noise, to give stable readings under adverse 
conditions. 
A wide range of output options for current, and uni-polar or bi-polar voltage can be configured by DIL switch 
settings. 
Both the AC and DC versions are based on a common board and are mounted in a light grey ABS case sealed to IP65 
standard.