Cleaning
Do not clean the appl icator wi th a high-pressur e spray o r with an i ntense water jet spray.
Clean ing du ring the season: During short breaks in the work day (a few hours), the herbicide can
remain in the system as long as the metering valve is closed. After completion of work task: before
cleaning, return the chemical into its original container. Set the metering valve to maximum (water
cock symbol). Fill the chemical tank half way with water, actuate the button switch and allow the
atomiser to run for 3 minutes over a collector tank or spread the cleaning fluid over the previously
worked surface. Remove the remaining water from the tank.
Clean ing aft er the season : Rinse the unit with warm water as described above. Additionally: open
filter and clean screen if necessary. The spray hood and the atomiser housing can be cleaned with
a moist cloth, except the atomiser disc in order to avoid damage. For heavy contamination, the
atomiser housing should be unscrewed to remove contaminants and plant parts. Connect the unit
to the battery charger (see below).
Charging t he applicat or and c are of the accumulat or
The applicator is fitted with an automatic charging device. Trickle charging is possible.
In order to charge a completely empty battery back up to full capacity, ca. 16 hours charging time is required. When a battery is
empty, it should be immediately recharged. Never leave a battery discharged for long periods.
Battery charging Min imum charging time Time interval
Fully discharged 16 hrs. immediately
Short-term usage 6 hrs. immediately
Storage without usage ( 2 hrs. 1 x per month) or permanent charge
The applicator can be used for ca. 16 hours with a fully charged battery.
Fault r emedy
Faul t Cause Remed y
Atomiser disc not Atomiser contaminated Thoroughly clean atomiser, remove plant parts if needed
turning Battery empty Charge battery
Fuse blown Replace fuse on powerpack
(Replacement fuses are located in the powerpack
housing)
No electrical contact Check cable or connector contact
Battery defective Install new battery
Atomiser motor defective Install new motor
Connect the brown cable to Plus (+).
Atomiser spray Rotation disc turning in the wrong direction Connect cable correctly!
one-sided Selectively plug the brown cable onto the contact pin
on the switch/valve unit
Connect the blue cable via the round pin plug.
Check to ensure the battery connection to the
powerpack is correctly poled, blue cable to Plus (+).
Atomiser spray too wide Width adjustment improperly set Loosen the screw F (see page 4) and correct the
width setting to the left or to the right, respectively
Atomiser drips Metering valve incorrectly set Check setting, see table
Atomiser disc defective / contaminated Replace / clean disc
Atomiser spray discharge contaminated Clean
Atomiser foams Residual water in system Completely empty container, hose, segmental atomiser.
Chemical no t Filter contaminated Unscrew filter, clean screen.
flowing evenly Metering valve clogged Set scale to maximum . Take off hose of upper
side of metering valve and blow through with
compressed air or use cleaning syringe
(accessory art.-no. 100348).
Air in hose line Hose connection Slightly shorten the hose and set onto a hose nipple.
/ Filter leaking Re-tighten the screw on the filter.