Manrose SF100T Instructions

Diagram D Professional Showerlite luminaire
Showerlite
luminaire
Grille installation
in soffit
installed in
shower
Ceiling
installation
Transformer (cut away)
DIAGRAM X1A
SIDE VIEW
Fan chassis
Screw
When screw is tightened fixing clip fingers secure the fan
Connections from the Showerlite to transformer can be
connected to either of the SEC 12V terminals
numbered 1 and 2 (polarity is not critical)
Connections from the Fan unit to the transformer must
be connected to PRI 230V terminals 3: Live and 4: Neutral
SHOWERFAN DIMENSIONS
Table 1
100mm/4" 100mm
120mm/5" 135mm
150mm/6" 155mm
Table 2
Fixing clip
SHOWERLITE DIMENSIONS
Recommended minimum Hole 0
TYPE/SIZE
Using Screws
100mm
Ceiling board
Typical Panel Fixing
120mm 150mm
102mm 115mm 120mm 135mm
150mm 165mm
Using Clips
5. Fitting the induct professional fan
Select a suitable place for the fan to be screwed to a joist and secure using two screws through the fixing bracket. A minimum of 500mm of ducting should be used either side of the fan, on the discharge of the luminaire and on the discharge of the outlet grill. Using the external grille select a suitable position either in the soffit or on an outside wall and cut a 4.5"/115mm hole. Attach one end of the flexible duct to the grille with one of the straps provided and from the outside feed the ducting through the hole until the grille is flush with the soffit/wall. Secure the grille to the wall. N.B. It is best not to cut the flexible ducting until the grille with the flexible ducting attached has been screwed to the outside surface so as to avoid the possibility of cutting the duct too short. Pull the flexible ducting gently to the discharge spigot of the fan and cut it to length and connect to the fan with another of the straps provided. NB: The discharge end of the fan is marked by an arrow showing the airflow
direction.
Connect the other piece of duct to the Showerlite and onto the fan as before using the other straps provided. Cut off and discard any excess ducting. N.B. Make sure wherever possible to keep the ducting running in a straight line as this will improve the performance of the fan. PLEASE NOTE: When installing the Professional Showerlite luminaire an
additional ceiling grille can be installed using the T-connector.
IMPORTANT: The Professional Showerlite luminaire is type 120mm.Lamp Type MR16 12V MAX 35W
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum
2
of 1mm
in section. All wiring must comply with current IEE Regulations. If in any doubt contact a qualified electrician. Fit the Blind Cable grommet in the cable entry hole and pierce with a 4mm diameter bradle or screw driver. Push the supply cable through the grommet leave enough cable to make the electrical connections always secure the supply cable with the cable grip. This unit is double insulated.
WARNING: Switch off mains supply before making any electrical connections. Installation must be supervised by a qualified electrician.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other open-fire appliances when mounted in outside windows or walls.
MAINTENANCE: Fan and luminaire must be disconnected from power supply and luminaire allowed to cool before any maintenance is carried out.
To change faulty lamps see page 4 – Installation of Showerlite luminaire & Professional Showerlite luminaire.
The Showerlite bezel can be removed and cleaned with a cloth
The Showerlite housing and fan can be cleaned with a cloth It is recommended to check the electrical connections annually
100mm 4
/120mm 5
/150mm 6
RANGE OF SHOWERFAN,
SLIMLINE FAN, CENTRIFUGAL SHOWERFAN, SHOWERLITE
LUMINAIRE AND PROFESSIONAL SHOWERLITE LUMINAIRE
Installation of Showerfan & Centrifugal Showerfan
1. The slimline fan can be fitted in a shower cubicle,next to baths and above taps
where regulations prevent installation of conventional fans.
Cut a hole in the ceiling (see table 1 for dimensions ) directly over the shower head
ensuring first that the area above is free from obstruction and between two joists. A minimum of 500mm of ducting should be used either side of the fan, on the discharge of the luminaire and on the discharge of the outlet grille.
Using the internal circular grille, carefully remove the grille from its housing by levering gently at the sides with a small screwdriver. Push the grille into the hole in
the ceiling and make sure it is square to the walls and then mark the position of the
fixing holes on the ceiling. Drill and plug the holes and screw the grille to the ceiling
then refit the grille to the chassis fitted to the ceiling.
Select a suitable place for the Fan to be screwed to a joist and secure using two
screws through the fixing bracket .
Using the external square grille select a suitable position either in the soffit or on an
outside wall and cut a 4.5"/115mm hole. Attach one end of the flexible duct to the
grille with one of the straps provided and from the outside feed the ducting through
the hole until the grille is flush with the soffit/wall. Secure the grille to the wall as
before.
Pull the flexible ducting gently to the discharge spigot of the fan and cut it to length
and connect to the fan with another of the straps provided.
NB: The discharge end of the Fan Unit is the end where you can see the fan
blade clearly. There is also an arrow on the unit showing airflow direction.
Connect the other piece of duct to the ceiling grille and onto the fan as before using
the other straps provided.
NB: Make sure wherever possible to keep the ducting running in a straight line as
this will improve the performance of the fan.
Remove the cover on the Fan Bracket and make the electrical connection as follows:
IMPORTANT: Fit the Blind Cable grommet in the cable entry hole and pierce with a
4mm diameter bradle or screw driver. Push the supply cable through the grommet
leave enough cable to make the electrical connections, secure the cable with the
cable grip.
Wiring of Standard Model.
The fan can either be operated from a separate pullcord switch fitted to the ceiling of
the shower room or can be connected to the light switch so that the fan will start
when the light is switched on. A double pole fused spur having a contact separation
of at least 3mm in all poles must be used and fitted with a 3amp fuse, and should be
sited outside any room containing a shower or fixed bath. The fan should not be
accessible to a person using either the shower or the bath.
2.
Wiring of Timer Model Diagram A
The fan can either be operated from a separate pullcord switch fitted to the ceiling of the shower room or can be connected to the light switch so that the fan will start when the light is switched on. A double pole fused spur having a contact separation of at least 3mm in all poles must be used and fitted with a 3amp fuse, and should be sited outside any room containing a shower or fixed bath. The fan should not be accessible to a person using either the shower or the bath. Note: All wiring must be fixed securely and the cable to the fan should be a mini­mum of 1mm any doubt contact a qualified electrician.
2
in section. All wiring must comply with current IEE Regulations. If in
Thumb Wheel
Diagram A
PULLCORD SWITCH
OR LIGHT SWITCH
3 AMP DOUBLE POLE FUSE
+ LIVE
- NEUTRAL
Diagram 1
This diagram is for a lighting circuit timer model
Important
Timer fans require 3 fixed wires to be connected
1. The neutral N (typical connection see diagram A)
2. The switched live (only live when the operating switch is in the on position) = S/L
3.The permanent live (always live) =L
3.
Installation of Slimline model Diagram B
Select suitable position for fan and cut a suitable diameter hole (see dimension below)
in the wall. Bring power cable into position as indicated in diagram B. Allow a minimum of 250mm (10) extra length. When cutting slot in ducting ensure it is correctly positioned for cable entry as diagram B. N.B. WARNING: Aluminium ducting has sharp edges. After passing cable through hole, extend flexible duct to width required (maximum 350mm long). Insert into hole and make good with duct flush either side. Do not build in cable at this stage see item B. Fix outer grey grille (fixed) into position. Insert backdraught shutter until it touches external grille. Wire up fan see internal label. Fan can either be operated from a separate pullcord switch fitted to the ceiling of the room or can be connected to the light switch so that the fan will start when the light is switched on. A double pole fused spur having a contact separation of at least 3mm in all poles must be used and fitted with a 3 amp fuse and should be sited outside any room containing a shower or fixed bath. Insert fan into duct as diagram A and sure a minimum of 175mm from face of wall to rear of fan chassis. Clip cable into self adhesive clips and place in position as indicated. (Ensure you apply foam tape around fan body). Make good around cable at edge of duct and fit internal fixed grille
Diagram B
Plaster 25-30mm
TYPICAL INSTALLATION
Breeze Block
100mm
Cavity Wall Insulation
100mm
Brick
100mm
SLIMLINE DIMENSIONS
100mm/4" 110mm
120mm/5" 140mm
Cable built into plaster/brickwork
Interior White Grille
INTERIOR
SHOWER/
BATHROOM
50mm x 10mm cut slot for cable entry
Self-adhesive Clips
Entry at bottom
Min 175mm from face of wall to rear of fan chassis
Induct Fan
90mm
Fan Casing
Extendable to 400mm
Backdraught Shutter
Fan Blade
Min 100mm
150mm/6" 173mm
Exterior Grey Grille
OUTSIDE AIR
077125 REV 2 03/10
4. Installation of Showerlite Luminaire& Professional Showerlite Luminaire
Diagram C / D
Hold the body of the Showerlite luminaire against the wall or ceiling and mark the four screw holes and the cable entry on the side. (Use the fixing clips to secure the fan in panel walls & ceilings). See diagram X1A. Connect the Transformer to the Showerlite luminaire and to a suitable power supply, ideally switched live of the Extractor Fan or Bathroom lighting circuit.
See diagram 1.
IMPORTANT: The Showerlite luminaire must not work independently of the fan. Immediate 12V power source to the down lighter must be short-circuit proof.
Where the installation does not permit connecting the LV leads from the lamp housing directly into the remote transformer an extended lead can be used
using wiring a minimum of 1mm sq in section, the terminal block included and a standard BS6220 5 amp junction box . Terminal block not included. Installation may require advice from a qualified person.
Place the ceiling cover onto the Showerlite luminaire Chassis by locating onto the 3 lugs, and twisting anti-clockwise. Never connect mains supply direct to the class III Showerlite luminaire. Power input - 12 volts AC 50VA
WARNING Disconnect the power supply, and be sure that the Lamp has fully cooled before removing or replacing. (Max Lamp Wattage 35 Watts)
When installed not suitable for covering with thermally insulated material. MAINTENANCE
Replace faulty dicrohic lamps with self-shielded type: MR16 12V MAX 35W
Luminaire can be cleaned with a damp cloth To change the Professional Showerlite lamp follow steps 1 - 5 below
1. Twist the lamp housing anticlockwise and lower from the Showerlite body.
2. Remove the lamp holder from the lamp pins
3. Remove old lamp and clip new lamp into lamp housing
4. Connect the lamp holder to lamp pins
5. Offer up the lamp housing and twist clockwise until
holding lugs engage and secure housing
(Do not over tighten)
To change the showerlite lamp
follow step 1-2 below
1. Remove faulty lamp by pulling out of lamp housing.
2. Replace new lamp by aligning the 2 lamp pins with the lamp holder in the lamp housing and pushing into position.
Diagram C - Showerlite Luminaire Model
the shower fan screwed to the joist
Flexible ducting
Showerlite
External grille