Manrose QF100S, QF100P, QF100T, QF100H, QF100TP Installation Manual

...
q u i e t
QF100S QF100P QF100T QF100H QF100TP QF100TH
MANROSE
u
i
e t
INSTALLATION:
IMPORTANT NOTES:
(i) When installing a fan through an external wall, an external wall grille must be fitted at all times. (ii) This fan must be installed by fixed wiring only. A flexible cord should not be used. (iii) A double pole fused spur having a contact separation of at least 3mm in all poles MUST be used and fitted with a 3A fuse. (iv) For best results this extractor fan should be fitted at least 1.8 metres from the floor or if prefered in the ceiling. Pullcord models are not suitable for installation in ceilings. (v) Do not install the unit within a shower cubicle or anywhere else where there is a risk of being sprayed with water (see our range of shower fans). Fan must be installed in the zone appropriate to its IP rating (stated on the rating label) and level of circuit protection present. For further guidance please refer to the zone diagram. (vi) Switch off mains supply before making electrical connections. All installations must be in accordance with building and wiring regulations, if in any doubt contact a qualified electrician. (vii) This fan is double insulated and does not require an earth.
Please read these instructions before installation.
Switch off mains supply before making any electrical connections, if you are in any doubt about the installation consult a qualified electrician. This appliance may be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other open-fire appliances when mounted in outside walls or windows.
Fan must be disconnected from electrical power before any maintenance or adjustment is carried out.
Zone diagram for locations with a bath or shower
1. Cut a 112mm (4
1/2
”) hole in the wall. If the fan is to be fixed in the ceiling ensure that the hole is
between the joists. Fit ducting flush to the plaster.
2. Remove the cover from the fan by removing the two small screw caps on the front cover and remove the two retaining Philips screws.
3. Hold the body of the fan against the wall or ceiling and mark the four screw holes and cable entry. IMPORTANT: Ensure the fan is square on the wall or ceiling.
4. Bring
power cable into position. Leave 230mm (9”) protruding to facilitate connection.
WINDOW
RECESS ZONE0
~
'-
--
0-U_TS_ID_E_Z_O_N_
ES
___
CEILING
,-
OUTSIDE
ZONES
2.25M