Manrose FAN5379, FAN5382 Instructions Manual

Fixing clip
Ceiling board
Screw
Fan chassis
When screw is tightened fixing clip fingers secure the fan
IMPORTANT
Isolate the mains supply before making any electrical connections. This system should be
installed by a qualified electrician.
When fitting through an external wall, an external grille must be fitted at all times.
Fan should only be installed by fixed wiring, a flexible cord should not be used.
The appliance is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
Precautions must be taken to avoid the back-flow of gases into the room from the open flue of
gas or other open-fire appliances when mounted in outside windows or walls.
INSTALLATION INSTRUCTIONS
PRO-SERIES
MANROSE PRO SERIES 125mm EXTRACT-A-LITE FAN RANGE
Thank you for selecting our Manrose Pro Series 125mm Extract-a-Lite Fan Kit.
Please read all instructions before commencing installation.
Please ensure the corrrect LED lamp and driver OR Halogen lamp and transformer are used for replacements. The LED model MUST be replaced with an LED lamp and the Halogen model MUST be replaced with a Halogen lamp. They are not interchangeable.
Flexible ducting
Internal Extract-a-Lite
We reserve the right to change specification without prior warning
The Shower Fan screwed to the joist
Manrose is proudly distributed by Simx Limited PO Box 14 347, Panmure, Auckland, NZ. Technical Support (09) 259 1662 e: sales@simx.co.nz | www.simx.co.nz | www.manrose.com.au
External Grille
Fan Specifications:
Electrical: 220-240V ~50Hz Airflow: 39l/s (140m³/hr) Wattage: 49W Max Temp: 50°C IP Rating: IPX4
PUB1099 iss03 10/13
Light Specifications: LED models: FAN5379- FAN5382
Driver Input: 220-240 VAC
Driver Output: 12VDC
Lamp MR16: 12V / 3W high power LED, 250 beam angle
Halogen models: FAN2029-FAN2032
Transformer Input: 220-240 VAC
Transformer Output: 12VAC
Lamp MR16: 12V / 50W Halogen, 600 beam angle
Installation Instructions
Important: The Halogen Extract-a-lite must not work independently of the fan.
1. Cut a 140mm diameter hole in ceiling, (always ensure the hole is cut between ceiling rafters and away from any wiring or plumbing). Fix the Extract-a-lite chassis using the 4 screws provided. Use the fixing clips to secure the fan in panel walls & ceilings.
2. For the LED models: Connect a suitable driver to the Extract-a-Lite and to a suitable power supply, ideally to the switched live of the extractor fan installed.
Recommended driver: FAN5342. Replacement lamp: LHT0221.
For the Halogen models: Connect a suitable transformer to the Extract-a-Lite and to a suitable power supply, ideally to the switched live of the extractor fan installed. Recommended transformer: FAN2101. Recommended lamp: FAN0431.
3. Place the white ceiling cover onto the Extract-a-lite chassis by positioning over the 3 lugs, and twisting clockwise.
4. Never connect mains direct to the lamp.
5. The transformer/driver must be suitable for 230V AC input. .
CAUTION: Disconnect the power supply, and be sure that the lamp has fully cooled before removing or replacing.
INSTALLATION
DIMENSIONS
165mm
115mm
80mm
Diagram 1 (ELLP125S) Standard Model This diagram is for a lighting circuit only
230VAC
Existing Switch
Existing
Light
FAN
230/12V AC SELV transformer OR LED Driver
12VAC
Diagram 2 (ELLP125T) Timer Model. This diagram is for a lighting circuit only
Switch
230VAC
Permanent Live
Switched Live
230/12V AC SELV transformer OR LED Driver
12VAC
Extract-a-Lite
Diagram 3
Live
Neutral
1 LIVE 2 NEUTRAL
Diagram 4
PLEASE NOTE:
This fan is double insulated and therefore does not require an earth. The time delay is preset for approximately one minute and can be adjusted as described.
3
2
1
Live
Live
Neutral
Recommended mounting
position for the timer model
Extract-a-Lite
12VAC light
12VAC light
FITTING THE INDUCT FAN
1. Select a suitable place for the centrifugal fan to be screwed to a joist and secure using two screws
through the fixing bracket. NB: The discharge end of the Fan unit is the end where you can see
the back draught shutter. There is also an arrow on the unit showing airflow direction.
2. For the exterior grille there is a choice of options, either a weatherproof cowl or a fixed grille. Select
a suitable position either in the soffit or on an outside wall for your chosen grille. Carefully remove the grille insert/cowl from its housing by levering gently at the sides with a small screwdriver. Cut a 140mm hole ensuring first that the area above is free from obstruction.
3. Attach one end of the flexible duct to the spigot with the duct tape provided and from the outside feed
the duct through the hole until the grille is flush with the soffit/wall. Mark the position of the fixing holes on the soffit/wall. Drill the holes and screw the grille to the soffit/wall then refit the chosen grille to the chassis. NB: It is best not to cut the flexible ducting until the grille has been screwed to the outside surface to avoid the possibility of cutting the duct too short.
4. Pull the flexible ducting gently to the discharge spigot of the fan and cut it to length and connect to the
fan. NB: The discharge end of the fan unit is the end where you can see the fan blade clearly.
5. Connect the other piece of duct to the Extract-a-lite and onto the fan. Cut off and discard any excess
ducting. NB. Make sure wherever possible to keep the ducting running in a straight line as this will improve the performance of the fan.
6. Remove the cover on the Fan Bracket and make the electrical connection as follows:
7. Wiring of Standard Model ELLP125S. Diagram 1 & 3
The fan can be connected to the light switch so that the fan will start when the light is switched on. The fan should not be accessible to a person using either the shower or the bath.
NB: All wiring must be fixed securely and the cable to the fan should be a minimum of 1mm² in section. All wiring must comply with current Regulations. This system should be installed by a qualified
electrician.
8. Wiring of Timer Model ELLP125T Diagram 2 & 4.
The fan can be connected to the light switch so that the fan will start when the light is switched on. When switched off the fan and Extraxt-a-Lite will continue to run on for between 20 seconds & 20 minutes (pre-set to 1 minute). The fan should not be accessible to a person using either the shower or the bath.
NB: All wiring must be fixed securely and the cable to the fan should be a minimum of 1mm² in section. All wiring must comply with Current Regulations. This system should be installed by a qualified electrician.
Timer Adjustment EL125T This time delay can be adjusted by firstly switching off the power to the fan and removing the fascia. Locate the rotary adjuster as shown in Diagram 4. The serrated adjuster wheel can be rotated using a thumbnail to adjust the timer setting.
+ = Rotate to the left to increase the time (indicated by + on the diagram)
- = Rotate to the right to decrease the time (indicated by - on the diagram)
Only adjust with power switched off.
DETAILED VIEW