Mannix IRT6 Operation Manual

Congratulations on your purchase of the Mannix Infrared Thermometer,model IRT6. The compact size lets you get into tight places while its convenient laser targeting and high distance-to-spot ratio give you accurate read­ings on distant targets .
• Precise non-contact Measurements
• Laser Target Pointer
• The meter provides simple one hand opera­tion and time saving temperature measure­ment. Be sure the measured object fills the “spot” seen by the aperture.
• There will be a delay of approximately one second between the time you initially press the button and the time the display comes on.
• Not recommended for measuring on shiny surfaces. The smaller the target, the closer the unit should be to it. To avoid thermal shock, do not store the meter below freez­ing.
• The meter is pre-set to measure objects with an emissivity of 0.95. This will accom­modate the majority of items measured without compensating for higher or lower value. In most cases there will be little dif­ference in measurements, even if an object’s emissivity is higher or lower than this pre-set value. Compare and confirm with known values if in doubt.
CAUTION
FRONT PANEL DESCRIPTION
1. IR Sensor
2. Laser Pointer Beam
3. LCD Display
4. Backlight Select Key
5. Laser Key
6. Measure Key
! Use extreme caution when the laser beam is
turned on.
! Do not point the laser toward the eyes or face
of a person or animal. Laser’s potential to cause damage is retained for hundreds of feet.
! Be careful not to let the beam on a reflective
surface strike your eye.
! Do not use near any flammable items or
gases.
Measuring Range: -4 to 788˚F (-20 to 420˚C) Resolution: 1˚F (1˚C) Accuracy: ±3˚C or ±3%
(whichever is greater)
Accuracy Notes:
1) Accuracy stated is for ambient temperature
2) Accuracy stated is for emissivity of 0.95
Emissivity: 0.95 fixed Distance Factor: D:S = Approx. 8:1 Sampling Rate: 500 m/sec. Display: LCD display with backlight Power Off: Automatic shut off after 8 seconds Operating Temp.: 32 to 122˚F (0 to 50˚C) Operating Humidity: Maximum of 80% RH Power Supply: 9-Volt Battery Power Current: Approx. 12mA DC Display Size: 0.75” x 1.375” Weight: 6.3 oz. (178g) Dimensions: 6.14” x 2.1” x 1.3”
INDICATORSPECIFICATIONS
1. Laser Icon
2. Digital Readout
3. ˚C (Celsius)
4. ˚F (Fahrenheit)
5. BAT (battery indicator)
8.8.8
˚F BAT
1 2
3 4
MEASUREMENT OPERATION
A. Power ON/OFF
The meter automatically powers up when the MEASURE key is pressed. Press the MEASURE key to read the measured temperature on the LCD. The meter powers off automatically approximately 8 seconds after the MEASURE key is released.
B.
Backlight LCD
Select backlight by first pressing the MEA­SURE key and then pressing the BACKLIGHT key. Repeat the procedure to turn the back­light off.
C.
Laser Pointer
To turn the laser pointer on, press the LASER key while pressing the MEASURE key. Repeat the procedure to turn the laser OFF
D. Measurement Considerations
While holding the meter, point the IR Sensor toward the object whose temperature is to be measured. The meter automatically compen­sates for temperature deviations from ambient temperature.
Keep in mind that it will take up to 30 minutes to adjust to wide ambient temperature changes. When low temperatures are to be measured followed by high temperature meas­urements, some time (several minutes) is required after the low (and before the high) temperature measurements are made. This is a result of the cooling process which must take place for the IR sensor.
BATTERY REPLACEMENT
A flashing display is the indication that the bat­tery voltage has fallen into the critical region (6.5 to 7.5 V). Reliable readings can be obtained for several hours after the first appearance of the low battery indication.
Open the Battery Compartment and remove the battery, then install a new battery and replace the cover.
TROUBLESHOOTING
? Meter does not turn on - Check voltage and
relace low battery. Or check time delay which is allowed 1 second for data to appear on­screen.
? Data flashing or laser comes on but no
data appears - Check battery voltage and
then replace low battery.
? Dashes appear on-screen
- Check extreme temperature, measure surrounding area to see if the target exceeds the limit.
MAINTENANCE
Case cleaning:
Clean the exterior housing of the unit with a damp cloth (use caution). Ensure no water or soap is allowed inside the meter or on the infrared lens.
Lens c
leaning:
WARNING: We recommend cleaning the lens periodically to ensure the reading accuracy.To remove any particles on the lens use low pres­sure compressed. If the contamination cannot be removed with air, use a soft cotton swab. The swab should be slightly damp and very light pressure should be applied. Do not use solvents to clean the lens.
1 2 3 4 5 6
Mannix Testing & Measurement is a leader in the field of temperature, humidity, air flow and digital technology. We offer a wide vari­ety of instruments including:
• Digital Thermometers
• Analog Thermometers
• Temperature & Humidity Monitors
• Digital Anemometers
• Digital Timers
• Stopwatch
• Weather Stations
• Rain Gauges
Please visit our website for additional infor­mation or to request a product catalog.
www.mannix-inst.com
OPERATION MANUAL
MODEL IRT6
Infrared Thermometer
Mannix Testing & Measurement
PO Box 866, Lynbrook NY11563
www.mannix-inst.com
This standard package contains:
• IRT6 infrared thermometer
• Battery (9.0 volt)
• Operation manual
• Carry pouch
• Wrist strap
MATERIALS SUPPLIED CE CERTIFICATION
WARRANTY
RETURN AUTHORIZATION
The meter is warranted to be free from defects in material and workmanship for a period of one year from the date of purchase. This war­ranty covers normal operation and does not cover battery, misuse, abuse,altera tion,tam­pering, neglect, improper maintenance, or damage resulting from leaking batteries. Proof of purchase is required for warranty repairs . Warranty is void if the meter has been opened.
Verbal or written authorization must be obtained from the supplier before returning items for any reason. When requesting an RA (Return Authorization) number,please include data regarding the reason for return. The meter must be returned along with original packing (including all accessories). To prevent any damage in shipment, one should insure the parcel against possible damage or loss.
The meter conforms to the following standards:
* EN 50081-1/1992: EN 55022 * EN 50082-1/1997: EN 55024
(EN 61000-4-2/-3/-8,ENV 50204)
The meter complies with the essential protec­tion requirements of Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromag­netic compatibility.
7 8