Manning VL
SECONDARY HEADLINE
Continuously monitor for potential leaks
in the vent lines of refrigeration systems
Manning VL
Vent Line Leak Detector
Beneficial Features
• Improves personnel, product and
equipment safety
• Extremely reliable sensor assembly
• Easy to calibrate and adjust
• Simple to install
• Continuous monitoring
• Can potentially lower insurance rates
• Input directly to central alarm systems
• Linear 4/20 mA output
The Manning Vent Line sensor continuously
monitors vent line headers for ammonia
and fluorocarbons.
The Manning Vent Line (VL) is designed to
continuously monitor for high concentrations
of ammonia or fluorocarbons in vent lines of
refrigeration systems.
High concentrations of refrigerant gases in vent
lines are warnings of system overpressure or
leaking relief valves. Either can pose danger to
employees and equipment. Wasted refrigerants
are costly and can mean overtime labor and
plant downtime.
Designed to be installed in refrigeration vent
lines, the VL sensor is supplied with a 2” cast
steel “T”, plug and nipple.
The sensor is embedded in a 2” forged steel
bull plug and houses a four-point terminal strip
for electrically connecting the sensor and preamp. The linear 4/20 mA output pre-amp is
housed in a separate enclosure.
The Manning Vent Line leak detector is
designed to be electrically connected to and
monitored by all Honeywell Analytics readouts
or can send a signal directly to a PLC.
Find out more
www.honeywellanalytics.com
Contact Honeywell Analytics:
USA, Central, and South America
Honeywell Analytics, Inc.
405 Barclay Boulevard
Lincolnshire, Illinois 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com
Please Note:
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions.
Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations,
standards, and guidelines. This publication is not intended to form the basis of a contract.
Technical Services
ha.service@honeywell.com
www.honeywell.com
Canada
Honeywell Analytics
3580 Rue Isabelle Unit 100
Brossard, Quebec
Canada
J4Y 2R3
Main Phone: +1.800.563.2967
Main Email: hasales.canada@honeywell.com
Main Fax: +1.450.619.2525
detectgas@honeywell.com
Applications
• Ammonia or Fluorocarbon Monitoring
of Refrigeration System Vent Lines
• Equipment Rooms
• Refrigeration Systems
Europe, Middle East, and Africa
Life Safety Distribution GmbH
Javastrasse 2, 8604 Hegnau
Switzerland
Main Phone: +41 (0)44 943 4300
Main Email: gasdetection@honeywell.com
Main Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
DS01015_V5 6/16
© 2016 Honeywell Analytics