Manitowoc Ice Q130 User Manual

Q130/Q210/Q270
UnderCounter Model
Ice Machines
Installation, Use & Care Manual
This manual is updated as new information and models are released.
Visit our website for the latest manual. www.manitowocfsg.com
America’s #1 Selling Ice Machine
Part Number 000001130 1/09
Safety Notices
! Warning
!
Caution
Important
!
Caution
Important
! Warning
!
Warning
As you work on Manitowoc equipment, be sure to pay close attention to the safety notices in this manual. Disregarding the notices may lead to serious injury and/ or damage to the equipment.
Throughout this manual, you will see the following types of safety notices:
Text in a Warning box alerts you to a potential personal injury situation. Be sure to read the Warning statement before proceeding, and work carefully.
Text in a Caution box alerts you to a situation in which you could damage the equipment. Be sure to read the Caution statement before proc eeding, and work carefully.
Procedural Notices
As you work on Manitowoc equipment, be sure to read the procedural notices in this manual. These notices supply helpful information which may assist you as you work.
Throughout this manual, you will see the following types of procedural notices:
Read These Before Proceeding:
Proper installation, care and maintenance are essential for maximum performance and trouble­free operation of your Manitow oc equipment. Read and understand this manual. It contains valuable care and maintenance information. If you encounter problems not covered by this manual, do not proceed, contact Manitowoc Foodservice Group. We will be happy to provide assistance.
Routine adjustments and maintenance procedures outlined in this manual are not covered by the warranty.
PERSONAL INJURY POTENTIAL
Do not operate equipment that has been misused, abused, neglected, damaged, or altered/modified from that of original manufactured specifications.
PERSONAL INJURY POTENTIAL
Children must be supervised to insure they do not play with this appliance..
Text in an Important box provides you with information that may help you perform a procedure more efficiently. Disregarding this information will not cause damage or injury, but it may slow you down as you work.
NOTE: Text set off as a Note provides you with simple, but useful, extra information about th e pr oce dur e yo u are performing.
Specifications and design are subject to change without notice.
NOTE: SAVE THESE INSTRUCTIONS.
Section 1 General Information
Model Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Model/Serial Number Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Owner Warranty Registration Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Section 2 Installation Instructions
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Ice Machine Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Location of Ice Machine. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Ice Machine Heat of Rejection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Leveling the Ice Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Electrical Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Water Service/Drains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Water Supply and Drain Line Sizing/Connections. . . . . . . . . . . . . . . . . . . . . . . 2-6
Before Starting the Ice Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Table of Contents
Bin Caster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Tri-liminator Water Filter System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Manitowoc Cleaner and Sanitizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Q130/Q210 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Commercial Warranty Coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Residential Warranty Coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Q130/Q210 Ice Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Q270 Ice Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Fuse/circuit breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Total Circuit ampacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Ground Fault Circuit Interupter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Q130/Q210/Q270 Ice machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Water Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Water Inlet Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Drain Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Cooling Tower Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Part Number 000001130 12/08 i
Section 3 Operation
Section 4 Maintenance
Table of Contents (continued)
Component Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Ice Making Sequence of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Initial Start-up Or Start-up After Automatic Shut-off . . . . . . . . . . . . . . . . . . 3-2
Freeze Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Harvest Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Automatic Shut-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Energized Parts Chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Operational Checks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Siphon System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
water Float Valve Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Water Level Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Ice Bridge Thickness Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Interior Cleaning and Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Cleaning And Sanitizing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Ice Machine Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Exterior Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Cleaning the Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Removal From Service Winterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Self-contained Air-Cooled Ice Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Water-Cooled Ice Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Section 5 Before Calling for Service
Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Safety Limit Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Safety Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
ii Part Number 000001130 12/08
Section 1
!
Warning
General Information
Model Numbers
This manual covers the following models:
Self-Contained
Air-Cooled
QR0130A QR0131W QD0132A QD0133W QY0134A QY0135W QR0210A QR0211W QD0212A QD0213W QY0214A QY0215W QR0270A QR0271W QD0272A QD0273W QY0274A QY0275W
PERSONAL INJURY POTENTIAL
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision concerning use of the appliance by a person responsible for their safety.
Self-Contained
Water-Cooled
Accessories
Contact your Manitowoc distributor for these optional accessories:
BIN CASTER
Replaces standard legs.
ARCTIC PURE WATER FILTER SYSTEM
Engineered specifically for Manitowoc ice machines, Arctic Pure water filters are an efficient, dependable, and affordable method of inhibiting scale formation, filtering sediment, and removing chlorine taste and odor.
MANITOWOC CLEANER AND SANITIZER
Manitowoc Ice Machine Cleaner and Sanitizer are available in convenient 16 oz. (473 ml) and 1 g al (3.7 8 l) bottles. These are the only cleaner and sanitizer approved for use with Manitowoc products.
Cleaner Part Number Sanitizer Part number
16oz 94-0456-3 16oz 94-0565-3 1 Gallon 94-0580-3 1 Gallon 94-0581-3
NOTE: The Manitowoc Automatic Cleaning System (AUCS®) accessory can not be used with models Q130, Q210 or Q270 ice machines.
Q130, Q210 and Q270 model ice machines do not have a water curtain covering the evapor ator. The ice damper performs the functions of the water curtain see Sectio n 4 for details.
Part Number 000001130 1/09 1-1
General Information Section 1
MODEL/SERIAL PLATE
LOCATION
MODEL/SERIAL PLATE
LOCATION
Model/Serial Number Location
Record the model and serial number of your ice machine in the space provided below. These numbers are required
when requesting information from your local
Manitowoc distributor, service represen tative, or
The model and serial number are listed on the OWNER WARRANTY REGISTRATION CARD. They are also listed on the MODEL/SERIAL NUMBER DECAL affixed to the ice machine.
Manitowoc Ice, Inc.
Q130/Q210 MODELS Q270 MODELS
1-2
Ice Machine
Model Number
Serial Number
Model/Serial Number Location
Part Number 000001130 1/09
Section 1 General Information
Important
Owner Warranty Registration Card
General
The packet containing this manual also includes warranty information. Warranty coverage beg ins the day your new ice machine is installed.
Complete and mail the OWNER WARRANTY REGISTRATION CARD as soon as possible to validate the installation date.
If you do not return your OWNER WARRANTY REGISTRATION CARD, Manitowoc will use the date of sale to the Manitowoc Distributor as the first day of warranty coverage for your new ice machine.
COMMERCIAL WARRANTY COVERAGE General
The following Warranty outline is provided for your convenience. For a detailed explanation , re ad the warranty bond shipped with each product.
Contact your local Manitowoc representative or Manitowoc Ice, Inc. if you need further warranty information.
Parts
1. Manitowoc warrants the ice machine against defects in materials and workmanship, under normal use and service for three (3) years from the date of original installation.
2. The evaporator and compressor are covered by an additional two (2) year (five years total) warranty beginning on the date of the original installation.
Labor
1. Labor required to repair or replace defective components is covered for three (3) years from the date of original installation.
2. The evaporator is covered by an additional two (2) year (five years total) labor warranty beginning on the date of the original installation.
Exclusions
The following items are not included in the ice machine’s warranty coverage:
1. Normal maintenance, adjustments and cleaning as outlined in this manual.
2. Repairs due to unauthorized modifications to the ice machine or use of non-standard parts without prior written approval from Manitowoc Ice, Inc.
3. Damage caused by improper installation of the ice machine, electrical supply , water supp ly or drainage, or damage caused by floods, storms, or other acts of God.
4. Premium labor rates due to holidays, overtime, etc.; travel time; flat rate service call charges; mileag e and miscellaneous tools and material charges not listed on the payment schedule. Additional labor charges resulting from the inaccessibility of equipment are also excluded.
5. Parts or assemblies subjected to misuse, abuse, neglect or accidents.
6. Damage or problems caused by installation, cleaning and/or maintenance procedures inconsistent with the technical instructions provided in this manual.
Authorized Warranty Service
To comply with the provisions of the warranty, a refrigeration service company, qualified and authorized by your Manitowoc distributor, or a Contracted Service Representative must perform the warranty repair.
NOTE: If the dealer you purchased the ice machine from is not authorized to perform warranty service, contact your Manitowoc distributor or Manitowoc Ice, Inc. for the name of the nearest authorized service representative.
Service Calls
Normal maintenance, adjustments and cleaning as outlined in this manual are not covered by the warranty. If you have followed the procedures listed in this manual, and the ice machine still does not perform properly, call your authorized service company.
Part Number 000001130 1/09 1-3
General Information Section 1
RESIDENTIAL WARRANTY COVERAGE WHAT DOES THIS LIMITED WARRANTY COVER?
Subject to the exclusions and limitations below, Manitowoc Ice, Inc. (“Manitowoc”) warrants to the original consumer that any new ice machine manufactured by Manitowoc (the “Product” ) shall be free of defects in material or workmanship for the warranty period outlined below under normal use and maintenance, and upon proper installation and start-up in accordance with the instruction manual supplied with the Product.
HOW LONG DOES THIS LIMITED WARRANTY LAST?
Ice Machine - Twelve (12) months from the sale date
WHO IS COVERED BY THIS LIMITED WARRANTY?
This limited warranty only applies to the original consumer of the Product and is not transferable.
WHAT ARE MANITOWOC ICE’S OBLIGATIONS UNDER THIS LIMITED WARRANTY?
If a defect arises and Manitowoc receives a valid warranty claim prior to the expiration of the warranty period, Manitowoc shall, at its option: (1) repair the Product at Manitowoc’s cost, including standard straight time labor charges, (2) replace the Product with one that is new or at least as functionally equivalent as the original, or (3) refund the purchase price for the Pr oduct. Replacement parts are warranted for 90 days or the balance of the original warranty period, whiche ve r is longer. The foregoing constitutes Manitowoc’s sole obligation and the consumer’s exclusive remedy for any breach of this limited warranty. Manitowoc’s liability under this limited warranty is limited to the purchase price of Product. Additional expenses including, without limitation, service travel time, overtime or premium labor charges, accessing or removing the Product, or shipping are the responsibility of the consumer.
HOW TO OBTAIN WARRANTY SERVICE
To obtain warranty service or information rega rding yo ur Product, please contact us at:
MANITOWOC FOODSERVICE
2110 So. 26
P.O. Box 1720,
Manitowoc, WI 54221-1720
Telephone: 920-682-0161 Fax: 920-683-7585
www.manitowocice.com
th
St.,
WHAT IS NOT COVERED?
This limited warranty does not cover, and you are solely responsible for the costs of: (1) periodic or routine maintenance, (2) repair or replacement of the Product or parts due to normal wear and tear, (3) defects or damage to the Product or parts resulting from misuse, abuse, neglect, or accidents, (4) defects or damage to the Product or parts resulting from improper or unauthorized alterations, modifications, or changes; and (5) defects or damage to any Product that has not been installed and/or maintained in accordance with the instruction manual or technical instructions provided by Manitowoc. To the extent that warranty exclusions are not permitted under some state laws, these exclusions may not apply to you.
EXCEPT AS STATED IN THE FOLLOWING SENTENCE, THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY OF MANITOWOC WITH REGARD TO THE PRODUCT. ALL IMPLIED WARRANTIES ARE STRICTLY LIMITED TO THE DURATION OF THE LIMITED WARRANTY APPLICABLE TO THE PRODUCTS AS STATED ABOVE, INCLUDING BUT NOT LIMITED TO, ANY WARRANTY OF MERCHANT ABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
IN NO EVENT SHALL MANITOWOC OR ANY OF ITS AFFILIATES BE LIABLE TO THE CONSUMER OR ANY OTHER PERSON FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY KIND (INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS, REVENUE OR BUSINESS) ARISING FROM OR IN ANY MANNER CONNECTED WITH THE PRODUCT, ANY BREACH OF THIS LIMITED WARRANTY, OR ANY OTHER CAUSE WHA TSOEVER, WHETHER BASED ON CONTRACT, TORT OR ANY OTHER THEORY OF LIABILITY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
HOW STATE LAW APPLIES
This limited warranty gives you specific legal rights, and you may also have rights that vary from state to state or from one jurisdiction to another.
REGISTRATION CARD
To secure prompt and continuing warranty service, this warranty registration card must be completed and sent to Manitowoc within thirty (30) days from the sale date. Complete the following registration card and send it to Manitowoc at the address shown.
1-4
Part Number 000001130 1/09
General
Important
Electrical Entrance
3/8” (0.95 cm) FPT Ice Making Water Inlet
1/2” (1.27 cm) Minimum FPT Water Condenser Outlet (water-cooled units)
3/8” (0.95 cm) FPT Water Condenser Inlet
1/2” (1.27 cm) FPT Bin Drain
26.0” (66 cm)
19.0” (48.3 cm)
32.5”
(82.6 cm)
3.3”
(8.3 cm)
6.0”
(15.25 cm)
10.25”
(26 cm)
15.25”
(38.7 cm)
12.3”
(31.2 cm)
6.5”
(16.5 cm)
26.5” (67.3 cm)
1.25” (3.2 cm)
2.1” (5.4 cm)
28.2" (71.5 cm)
30.0" (76.2 cm)
20.7" (52.6 cm)
6.0"
(15.25 cm)
32.5"
(82.6 cm)
1/2" (1.27 cm) Bin Drain
Electrical Entrance 3/8" (0.95 cm) F.P.T.
Ice Making Water Inlet
1/2" (1.27 cm) F.P.T. Water Condenser Outlet (water-cooled units)
1/2" (1.27 cm) F.P.T. Water Condenser Inlet
1.25"
(3.2 cm)
6.8"
(17.4 cm)
11.2"
(28.4 cm)
8.8"
(22.4 cm)
13.5"
(34.2 cm)
12.4"
(31.4 cm)
2.125"
(5.4 cm)
Section 2
Installation Instructions
These instructions are provided to assist the qualified installer.
Failure to follow these installation guidelines may affect warranty coverage.
Ice Machine Dimensions
Q130/Q210 ICE MACHINES Q270 ICE MACHINES
Part Number 000001130 12/08 2-1
Installation Instructions Section 2
!
Caution
Location of Ice Machine
The location selected for the ice machine must meet the following criteria. If any of these criteria are not met, select another location.
The location must be indoors.
The location must be free of airborne and other contaminants.
The air temperature must be at least 40°F (4.4°C), but must not exceed 110°F (43.4°C).
The location must not be near heat-generating equipment or in direct sunlight.
The location must be capable of supporting the weight of the ice machine and a full bin of ice.
The location must allow enough clearance for water, drain and electrical connections in the rear of the ic e
machine.
The location must not obstruct airflow through or around the ice machine (condenser airflow is in and out the front). Refer to the chart below for clearance requirements.
Ice Machine Heat of Rejection
Series
Ice Machine
Q130 2400 2900 Q210 2400 3400 Q270 3800 6000
* B.T.U./Hour ** Because the heat of rejection varies during the ice making cycle, the
figure shown is an average.
Air Conditioning** Peak
Ice machines, like other refrigeration equipment, reject heat through the condenser. It is helpful to know the amount of heat rejected by the ice machine when sizing air conditioning equipment where self-contained air­cooled ice machines are installed.
Heat of Rejection*
Self-Contained
Air-Cooled
Top/Sides 5” (203 mm)* 5” (127 mm)*
Back 5” (127 mm)* 5” (127 mm)*
Self-Contained
Water-Cooled
NOTE: The ice machine may be built into a cabinet. There is no minimum clearance requirement for the top
or left and right sides of the ice machine. The listed values are recommended for efficient operation and servicing only.
The ice machine must be protected if it will be subjected to temperatures below 32°F (0°C). Failure caused by exposure to freezing temperatures is not covered by the warranty. See “Removal from Service/Winterization” Section 4.
2-2
Part Number 000001130 12/08
Section 2 Installation Instructions
!
Caution
THREAD LEVELING LEG INTO BASE OF
CABINET
Leveling the Ice Machine
1. Screw the lev elin g leg s on to the bott om of th e ice machine.
2. Screw the foot of each leg in as far as possible.
The legs must be screwed in tightly to prevent them from bending.
3. Move the ice machine into its final position.
4. Level the ice machine to assure that the siphon system functions correctly. Use a level on top of the ice machine. Turn each foot as necessary to level the ice machine from front to back and side to side.
NOTE: An optional 2 ½" caster assembly is available for use in place of the legs on the Q130, Q210 and Q270. Installation instructions are supplied with the casters.
Checking Ice Machine Level
Part Number 000001130 12/08 2-3
Installation Instructions Section 2
!
Warning
!
Warning
!
Warning
Electrical Service
GENERAL
All wiring must conform to local, state and national codes.
VOLTAGE
The maximum allowable voltage variation is ± 10% of the rated voltage on the ice machine model/serial number plate at start-up (when the electrical load is highest).
The 115/1/60 ice machines are factory pre-wired with a 8’ power cord, and NEMA 5-15P-plug configuration.
The 208-230/1/60 and 230/50/1 ice machines are factory pre-wired with a 8’ power cord only, no plug is supplied.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for each ice machine. Circuit breakers must be H.A.C.R. rated (does not apply in Canada).
The ice machine must be grounded in accordance with national and local electrical codes.
TOTAL CIRCUIT AMPACITY
The total circuit ampacity is used to help select the wire size of the electrical supply.
The wire size (or gauge) is also dependent upon location, materials used, length of run, etc., so it must be determined by a qualified electrician.
GROUND FAULT CIRCUIT INTERUPTER
Ground Fault Circuit Interrupter (GFCI/GFI) protection is a system that shuts down the electric circuit (opens it) when it senses an unexpected loss of power, presumably to ground. Manitowoc Ice, Inc. does not recommend the use of a GFCI/GFI circuit protection with our equipment. If code requires the us e of a GF CI /G FI then you must follow the local code. The circuit must be dedicated, sized properly and there must be a panel GFCI/GFI breaker. We do not recommend GFCI/GFI outlets as they are known for more intermittent n uisance trips than panel breakers.
PERSONAL INJURY POTENTIAL
If the supply cord is damaged, do not operate the equipment until the cord is replaced by a service agent or similarly qualified person..
Q130/Q210/Q270 ICE MACHINE
Voltage
Ice Machine
Q130
Q210
Q270
Danfoss
Compressor
Q270
Tecumseh
Compressor
Phase
Cycle
115/1/60 15 7.0 15 6.3
208-230/1/60 15 3.1 15 2.6
230/1/50 15 3.0 15 2.5 115/1/60 15 6.5 15 6.1
208-230/1/60 15 3.6 15 3.1
230/1/50 15 3.6 15 3.1 1 15/1/60 15 10.7 15 9.9
208-230/1/60 15 5.2 15 4.7
230/1/50 15 5.2 15 4.7 115/1/60 15 8.5 15 7.7
208-230/1/60 15 4.5 15 4.0
230/1/50 15 4.5 15 4.0
Air-Cooled Water Cooled
Maximum Fuse/
Circuit Breaker
Total Amps
Maximum Fuse/
Circuit Breaker
Total Amps