K00177
IB-0620/0820/1020
ON A CORNELIUS ABS OR ED150 ICE DISPENSER
Installation Instructions
1. Set adapter on top of the dispenser. Be sure to position the adapter with the backside flange tight to the dispenser.
2. Using the slotted holes in the adapter as a template, drill four (4) 9/64” diameter holes at the bottom of the slots.
NOTE: Do not drill deeper than 1/4” past the sheet metal. Use a drill stop!
3. Fasten adapter to dispenser using the four (4) #8 screws supplied with the adapter kit.
4. Set the ice machine on top of the adapter. Align holes in ice machine front angle with the rivnuts on the adapter.
5. Secure the ice machine to the adapter with two (2) #8-32 thumbscrews supplied with the ice machine.
6. Set the front bin cover onto the dispenser. The back flange of the bin cover will latch onto the adapter.
7. Rotate retaining arms into position, as shown for normal ice machine operation.
#8-32 Thumbscrew
2 Places
Adapter
LH Retaining Arm
#8 Screw
4 Places
Dispenser
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 8005843
Web Site - www.manitowocice.com Rev. 04/12/02