Manitowoc Ice AuCS-SI User Manual

AuCS® Automatic Cleaning System
Model
AuCS – SI (Internal Mounting) AuCS – SO (External M ounting)
Standard Features
AuCS – SI
• Internally mounted on S-Series Manitowoc
ice machines.
• Electricity drawn directly from ice machine.
• Can be ordered separately or installed at
the factory for no additional cost.
AuCS – SO
• Electricity drawn from ice machine directly.
• Exterior finish is stainless steel.
• Only 12" (30.48 cm) wide, 3.43" (8.7 cm)
deep, 12.12" (30.78 cm) high.
AuCS® Automatic Cleaning System
Warranty
AuCS – SI (Internal Mounting)
An efficient, dependable, and affordable accessory that schedules and performs routine ice machine cleaning automatically.
The innovative AuCS® accessory virtually eliminates the need to have a service technician perform manual cleaning procedures on
the water distribution system of your Manitowoc ice machine.
It is a known fact that regularly scheduled preventative maintenance (cleaning) reduces the total operating cost of any ice
machine. With AuCS, you simply select the cleaning frequency (2, 4, or 12 weeks); AuCS does the rest...automatically. AuCS is also
affordable, as the entire system costs less than the expense of 3 manual cleanings. AuCS-SI and AuCS-SO are designed for use with
only Manitowoc S-Series ice machines.
Cleaning or Sanitizing:
• The AuCS accessory can dispense either cleaner or
sanitizer. It can not dispense both at the same time. Refer
to the Installation Use and Care Manual supplied with the
AuCS accessory to determine the type of solution needed
and proper procedure for changing solutions. Use only
Manitowoc ice machine cleaner or sanitizer.
• Cleaner is used to remove and control build up of lime
scale or other mineral deposits.
• Sanitizer is used to control algae (slime) and other air
borne bacteria (yeast).
AuCS – SO (External Mounting)
Electric
• 115/60/1. 208-230/50/60/1 also available for both
SI and SO models.
• Total Amps: 0.3
• Max Fuse Size: 15 amps
Replenishment
• AuCS cleaning or sanitizing fluid is provided in either 16 oz.
replacement bottles or 1 gallon containers for refilling.
• 3-year warranty covering all parts and labor
from the date of original installation.
2110 South 26th Street
PO Box 1720
Manitowoc, WI 54221-1720 USA
Tel: 1.920.682.0161
www.manitowocice.com
AuCS® Automatic Cleaning System
AuCS – SI (Internal Mounting)
AuCS – SO (External Mounting)
4.75"
(12.06 cm)
10.00" (25.4 cm)
5.00" (12.7 cm)
Compatibility: The S-Model AuCS (AuCS – SI and AuCS – SO) accessory
can be used only on S-Series ice machines.
AuCS-SO
S-300
S-322
S-422
S-1470C
S-1870C
S-2070C
AuCS-SI
S-450 through
S-1800
3.43"
(8.71 cm)
12.00" (30.48 cm)
12.12"
(30.78 cm)
2.00" (5 cm)
Box Base Or Box Top Must Be Within 2" Of Ice Machine Base
NOTE: Box must also mount within reach of 9 foot (274 cm) tubing and low voltage modular wire.
9' (2.73 m)
Base Of Ice Machine
(Too High)
2.00" (5. cm)
NO!
NO!
(Too Low)
AuCS-SI Installation: The AuCS-SI mounts internally in S-Series ice
machines. S-Series ice machines can be ordered direct from the factory
with the AuCS-SI installed. If the AuCS-SI is not factory installed, a trained
and qualified technician must perform installation. Note: Line voltage is
obtained from the ice machine. Refer to the Model/Serial Plate on the ice
machine and the AuCS-SI to verify both voltages are the same.
AuCS-SO Installation: The AuCS-SO is mounted on the wall near the ice
machine or on the bin with the included bracket and hardware. Note:
Line voltage is obtained from the ice machine. Refer to the Model/Serial
Plate on the ice machine and the AuCS-SO to verify both voltages are
the same.
Setting Run Frequency: AuCS is set to run once approximately every
2 weeks. For less frequent cleanings, set selector switch as needed:
WEEKS CYCLES
2 1,120 4 2,240
12 6,720
Automatic Operation: Automatic cleaning initiated by the AuCS system
takes approximately 30 minutes to complete. The cleaning procedure
includes a 1-minute cleaning cycle followed by 6 rinse cycles.
Sequence of Operation:
Cleaning or Sanitizing Cycle
The cleaner or sanitizer is dispensed from
the AuCS accessory for 10-20 seconds
during the beginning of the cycle. The
water pump circulates water over the
evaporator for 10 minutes. After 10
minutes of cleaning, the water dump
valve energizes for 45 seconds to dump
the wash water down the drain.
Rinse Cycles
The entire rinse cycle is repeated 6 times.
The water pump circulates water over
the evaporator for 90 seconds. The water
dump valve energizes to dump the rinse
water down the drain for 45 seconds.
2379E ©2010 Ma nitowoc 1 /10 Con tinuing product i mprovement may ne cessitate change of speci fications without notice.
2110 South 26th Street
PO Box 1720
Manitowoc, WI 54221-1720 USA
Tel: 1.920.682.0161
www.manitowocice.com
Loading...