Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications.
AuCS®-SI
The AuCS®-SI mounts internally in S Model ice
machines. S Model Ice Machines can be ordered direct
from the factory with the AuCS®-SI installed (refer to
chart for available models). If your ice machine has a
factory installed AuCS®-SI, proceed to Section 3
Operation.
If the AuCS®-SI was not factory installed a trained and
qualified technician must perform the installation.
AuCS®-SO
The AuCS®-SO is mounted on the wall near the ice
machine, or on the bin with the included bracket and
hardware.
The AuCS®-SO must be installed by a trained and
qualified technician.
NOTE: Automatic Cleaning Systems are not compatib le
with S Model 3000 Series, S Model Flake/Nugget or
SM50 model ice machines.
Part Number 000007647 06/113
Section 2
Important
!
Warning
!
Warning
Water Inlet
Tubing
Plug Location
Press up on
bottom of plug
to pop out
Installation Instructions
General
These instructions are provided to assist the qualified
installer. Check your local Yellow Pages for the name of
the nearest Manitowoc distributor, or call Manitowoc
Foodservice for information regarding start-up service s.
Please contact you local Manitowoc Distributor or call
Manitowoc Foodservice for assistance if you encounter
a problem that is not covered by this manual.
Failure to follow these installation guidelines may
affect warranty coverage. Improper installation will
affect dispensing rate. Install only within the
parameters outlined in this installation manual.
Electrical Service
GENERAL
A trained and qualified technician must install the
AuCS®-SI or AuCS®-SO.
AuCS®-SI Installation
1. Disconnect power to ice machine at the electrical
disconnect.
Disconnect power to ice machine at the electrical
disconnect. Moving the ice machine toggle switch to
the off position does not disconnect line voltage.
2. Remove right front door.
3. Remove the water trough.
4. Locate the water inlet tube on the right hand side
(see below) of the ice machine base. Directly to the
left of the tube there is a small plug that must be
removed. Press up on the plug until it is out.
AuCS®-SI
Line voltage is obtained from the ice machine. Refer to
the Model/Serial plate on the ice machin e an d
AuCS®-SI to verify both voltages are the same.
AuCS®-SO
Line voltage is obtained from the ice machine or an
electrical outlet. Verify the ice machine voltage matches
the AuCS®-SO or a receptacle with the correct voltage
is available at the AuCS®-SO mounting location.
Voltage Phase CycleAmperage
1 15/1/600.3
208-230/1/50/600.1
5. Locate the plug and remove it from the ice machine.
6. Install Y connector through the hole in the ice
machine base. Connect the clear vinyl tubing to one
side of the Y branch, the other side is for the plug
removed in step 5.
4 Part Number 000007647 06/11
Section 2Installation Instructions
Route tubing
to this area
Insert Y
connector
with tubing
Connect
tubing
Install plug
removed in
Step 5
Into Base of
Ice Machine
Line Voltage
Heyco
Fittings
Connect to
incoming power
supply of contactor
observing proper
polarity for 115V
Connect
ground wire
to ground
screw
Low Voltage
Heyco Fitting
Control Board
Connection
SCREW
LOCATION
12
11B
11A
8. Route modular wire through control box low voltage
heyco fitting. Do not route with line voltage wiring,
erratic operation could result. Connect modular wire
to control board.
9. Remove screw from ice machine base.
Top View
10. Remove cover from AuCS®-SI.
Y-Connector
7. Route line voltage wires through control box line
voltage heyco fitting. Connect line voltage wires to
incoming power supply of contactor and ground
screw.
NOTE: On S QuietQube Ice Machines the power
connection is made at the incoming power supply
11. Slide the AuCS®-SI partially into ice machine below
control box.
A. Connect vinyl tubing to AuCS®-SI pump outlet.
B. Route communication wire (4 prong plug)
through left heyco fitting and attach to
AuCS®-SI control board.
(L1 and L2). Cut-off yellow terminal (L2) and purple
terminal (L1) on AuCS harness. S trip insulation back
1/2" (13 mm) and connect.
Part Number 000007647 06/115
12. Use screw removed in step 6 to secure AuCS®-SI to
the ice machine.
Installation InstructionsSection 2
!
Warning
!
Warning
Important
!
Caution
!
Caution
!
Caution
BASE OF ICE
MACHINE
2"
(5 cm)
BOX BASE OR BOX TOP
MUST BE WITHIN 2"
(5 cm) OF ICE MACHINE
BASE
AuCS®-SO Installation
LOCATION / MOUNTING
All wiring must conform to local, state and national
codes.
The ice machine and AuCS®-SO must be grou nded
in accordance with national and local electrical
codes.
Observe correct polarity of incoming line voltage.
The location selected for the AuCS®-SO accessory
must meet the following criteria. If any of these criteria
are not met, select another location.
•The location must be free of airborne and other
contaminants.
•The air temperature must be at least 40°F (4°C), but
must not exceed 110°F (43°C).
•The location must not be near heat-generating
equipment or in direct sunlight.
HEIGHT REQUIREMENT
Either the base or the top of the AuCS®-SO accessory
must be within 2" (5 cm) of the base of the ice machine.
Do not mount the AuCS®-SO too high or too low.
The cleaner or sanitizer may siphon (or dispense
improperly) into the ice machine water trough if the
AuCS®-SO is mounted too high or too low.
DISTANCE REQUIREMENT
The AuCS®-SO must be mounted within 9 feet (2.7 m)
of the ice machine to accommodate the low voltage
communication wire and tubing. The tubing may be
shortened to accommodate a run of less than 9 feet
(2.7 m).
Do not extend the length of the 9-foot (2.7 m) low
voltage communication wire or tubing. The correct
amount of solution will not dispense.
The AuCS® accessory must be protected if it will be
subjected to temperatures below 32°F (0°C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty. See
“Removal from Service/Winterization”.
6
Part Number 000007647 06/11
Section 2Installation Instructions
!
Caution
1/2" PVC CONDUIT
FITTING
HOSE CLAMPS
LOCKNUT
BUMPER
FOAM TAPE
BRACKET
AuCS
T
M
Mounting
Bracket
Gasket
Bumper
6.56 in.
(16.6 cm)
MOUNTING
Parts
4. Remove the backing from the adhesive bumpers.
Attach bumpers to the mounting bracket directly
above the AuCS®-SO control box. This eliminates
upward movement and stops the tabs from
disengaging the key slots.
M
T
AuCS
Mounting to Ice Machine
Mounting to Wall
The AuCS®-SO is mounted to the wall using the two key
slots in the back wall of the accessory. Screw fasteners
(not supplied) must hold the entire weight of the
AuCS®-SO (approximately 10 lbs. [4.5 kg]).
The AuCS®-SO may be mounted to the bin or
dispenser only when permitted by local electrical
codes.
Mounting to Bin or Dispenser
NOTE: The ice machine’s serviceability may be reduced
when the AuCS®-SO is mounted to the bin or dispenser.
Wall mounting is recommended.
1. Set the mounting bracket over the bin top rail at
Key Slot Dimensions
desired location.
2. Remove the backing from the foam adhesive tape.
Apply tape to mounting bracket, and along the en tire
bin rail.
3. Align the AuCS®-SO key slots with the mounting
bracket tabs. V eri fy the t abs are at the top of the key
slots and that the AuCS®-SO is level.
Part Number 000007647 06/117
Installation InstructionsSection 2
!
Warning
Line Voltage
Heyco
Fittings
Connect to
incoming power
supply of contactor
observing proper
polarity for 115V
Connect
ground wire
to ground
screw
Low Voltage
Heyco Fitting
Control Board
Connection
AuCS
Communication
Plug Connection
CONNECTION TO ICE MACHINE
Electrical Connections
1. Check electrical code for your area.
•When local code allows, the included wire and strain
relief can be used for line voltage wiring. Remove
knockout from ice machine and install strain relief
and wire.
•When conduit is required remove strain relief and ice
machine electrical knockout. Install conduit as
required by your electrical code.
Disconnect the electrical power supply to the ice
machine at the electrical disconnect before
proceeding.
•Connections on ice machines vary. Refer to the
diagram for the ice machine you are working on. If
the model you are working on is not shown, refer th e
model’s Installation, Use and Care Manual.
2. Remove the front, top, and right side panels from the
ice machine.
Communication Wire and Vinyl Tubing
The communication wire and vinyl tubing must be
installed in conduit to protect them from damage.
1. Remove the 7/8" access hole plug located on the
back of the ice machine.
2. Install conduit from the AuCS to the ice machine. A
pulling elbow is recommended for easier routing of
the vinyl tubing and modular wire.
3. Route low voltage communication wire and vinyl
tubing together through the conduit.
4. Route modular wire through control box low voltage
heyco fitting. Do not route with line voltage wiring,
erratic operation could result. Connect modular wire
to control board.
3. Route line voltage wires through control box line
voltage heyco fitting. Connect line voltage wires to
incoming power supply of contactor and ground
screw.
NOTE: On S QuietQube Ice Machines the power
connection is made at the incoming power supply (L1
and L2). Cut-off yellow terminal (L2) an d purp le ter minal
(L1) on AuCS harness. Stri p insulation back 1/2" and
connect.
8
5. Connect the communication wire to the AuCS
control board.
Part Number 000007647 06/11
Section 2Installation Instructions
Water Inlet
Tubing
Plug Location
Press up on
bottom of plug
to pop out
Route tubing
to this area
Insert Y
connector
with tubing
Connect
tubing
Install plug
removed in
Step 3
Into Base of
Ice Machine
Use hose
clamp to
secure tubing
to pump
Vinyl Tubing Connection
1. Remove the water trough.
A. Depress tabs on right and left side of the water
trough.
B. Allow front of water trough to drop as you pull
forward to disengage the rear pins.
2. Locate the water inlet tube on the right hand side
(see below) of the ice machine base. Directly to the
left of the tube there is a small plug that must be
removed. Press up on the plug until it is out.
4. Install Y connector through the hole in the ice
machine base. Connect the clear vinyl tubing to one
side of the Y branch, the other side is for the plug
removed in step 3.
Top View
Y-Connector
5. Determine the amount of tubing required in the
AuCS control box and cut off the excess tubing.
6. Slide the 3/8" hose clamp onto the tubing and
connect it to the fitting on the AuCS®-SO pump.
3. Locate the plug and remove it from the ice machine.
Part Number 000007647 06/119
Section 3
!
Caution
!
Warning
Important
Operation
Determine Type of Solution Needed
Use only Manitowoc approved Ice Machine
Cleaner & Sanitizer. It is a violation of Federal law
to use these solutions in a manner inconsistent
with their labeling. Read and understand all labels
on the bottles before use.
The AuCS® accessory will dispense Cleaner OR
Sanitizer. It cannot dispense both at the same time.
MANITOWOC ICE MACHINE CLEANER
Part Number 94-0546-3 (AuCS®-SO)
Part Number 40-1326-3 (AuCS®-SI)
Ice Machine Cleaner is used to control build-up and to
remove lime scale or other mineral deposits. It will not
“sanitize” the ice machine.
It is recommended for use in places that have lime scale
or other mineral deposits, but no problems with slime.
ModelAmount of Cleaner Dispensed
22" or 30"
Ice Machine
48" Ice Machine6 oz (177 ml)
3 oz (88 ml)
Hose Priming
The dispenser pump requires priming after initial
installation, or if the hose between the AuCS®-SI
reservoir and pump has been pumped dry or the tubing
between the AuCS®-SO pump and the ice machine has
been pumped dry.
Do not blow into or suck on the hose in an attempt
to prime it.
Perform the following procedure:
1. Move the ice machine toggle switch to CLEAN.
2. The water pump and dump valve will turn on. The
dump valve will shut off after approximately
45 seconds.
3. The control waits until water contacts the water level
probe then energizes the AuCS® pump (22" or 30"
ice machines - 30 seconds, 48" ice machines 60 seconds).
4. Allow the ice machine to complete the cleaning or
sanitizing cycle. Refer to “Manual Start Operation”
for details.
MANITOWOC ICE MACHINE SANITIZER
Part Number 94-0565-3 (AuCS®-SO)
Part Number 40-1327-3 (AuCS®-SI)
Ice Machine Sanitizer is used for sanitizing and
controlling algae build-up (slime) and other bacterial
growth. The ice machine (and bin or dispenser ) must be
sanitized on a regular schedule, following Manitowoc
recommendations and local regulations.
It is recommended for use in places such as pizzerias,
bars, bakeries, etc., that have airborne bacteria (yeast).
Sanitizing is also recommended in places that do not
have lime scale (or other mineral deposit problems).
ModelAmount of Sanitizer Dispensed
22" or 30"
Ice Machine
48" Ice Machine6 oz (176 ml)
3 oz (88 ml)
The priming procedure starts the automatic cle aning
mode. Upon moving the ice machine toggle switch
to ICE, the ice machine will run through 6 rinse and
dump cycles before making ice.
10 Part Number 000007647 06/11