Manitowoc Ice 7629661 User Manual

7629661 BIN THERMOSTAT
WATER SHIELD ASSY.
QM-30 Installation Instructions Only
IF USED ON A QM-20, REPLACEMENT BRACKET AND SHIELD ARE NOT USED.
INSTALL BIN THERMOSTAT ONLY.
1. Remove back panel.
Remove and discard the bracket.
3. Drill new 9/64” [3.5mm] diameter holes in the cabinet exterior flange 1.25” [31.75mm] above the existing holes. Attach the
thermostat to the shield using the M4 x 7 screws supplied. Attach the shield to the cabinet using the 8-32 x .500” screws supplied.
4. Press the shield firmly into the foam. Seal the top, left side, and right seams with RTV.
5. Locate and drill 3/16” [4.76mm] diameter holes in the lower back panel above the water inlet valve. Install the water inlet
valve shield using two 10-24 x .500” hex head screws supplied.
6. Install the back panel.
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 8012133 Web Site - www.manitowocice.com Rev. 07/09/04
3.875”
[98.43mm]
Bin Thermostat Shield
1.375”
[34.93mm]
.625”
[15.88mm]
Water Inlet Valve Shield